Voltammetric Study of the Antihistamine Drug Bilastine: Anodic Characterization and Quantification Using a Reusable MWCNTs Modified Screen Printed Carbon Electrode
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10174/28379 https://doi.org/Jorge Ginja Teixeira, João Oliveira, Electroanalysis, 08 November 2020 https://doi.org/10.1002/elan.202060494 (10 pages) https://doi.org/http://dx.doi.org/10.1002/elan.202060494 https://doi.org/10.1002/elan.202060494 |
Resumo: | The anodic behaviour and the electroanalytical quantification of the second‐generation antihistamine bilastine (BIL) were investigated for the first time. A multi‐walled carbon nanotubes (MWCNTs) film‐coated screen printed carbon electrode (SPCE), as well as cyclic (CV) and linear sweep (LSV) voltammetry, were used for that purpose. The results showed that BIL undergoes an irreversible two‐electron oxidation process at the MWCNTs‐SPCE sensor. It was also found that the sensor can be reused after a simple and rapid reconditioning procedure. The proposed method was applied to the quantification of BIL in pharmaceutical formulations and spiked urine samples, and good recoveries were obtained. |
id |
RCAP_b492e2549b3f5d723e3ab25f21c7e78c |
---|---|
oai_identifier_str |
oai:dspace.uevora.pt:10174/28379 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Voltammetric Study of the Antihistamine Drug Bilastine: Anodic Characterization and Quantification Using a Reusable MWCNTs Modified Screen Printed Carbon ElectrodeAntihistamineBilastineMulti-walled carbon nanotubes (MWCNTs)Screen printed carbon electrode (SPCE)Voltammetric determinationThe anodic behaviour and the electroanalytical quantification of the second‐generation antihistamine bilastine (BIL) were investigated for the first time. A multi‐walled carbon nanotubes (MWCNTs) film‐coated screen printed carbon electrode (SPCE), as well as cyclic (CV) and linear sweep (LSV) voltammetry, were used for that purpose. The results showed that BIL undergoes an irreversible two‐electron oxidation process at the MWCNTs‐SPCE sensor. It was also found that the sensor can be reused after a simple and rapid reconditioning procedure. The proposed method was applied to the quantification of BIL in pharmaceutical formulations and spiked urine samples, and good recoveries were obtained.Wiley2020-11-23T14:55:25Z2020-11-232020-11-08T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10174/28379https://doi.org/Jorge Ginja Teixeira, João Oliveira, Electroanalysis, 08 November 2020 https://doi.org/10.1002/elan.202060494 (10 pages)https://doi.org/http://dx.doi.org/10.1002/elan.202060494http://hdl.handle.net/10174/28379https://doi.org/10.1002/elan.202060494eng1521-4109HERCULES - Laboratório HERCULES - Herança Cultural, Estudos e Salvaguarda (HERCULES - Publicações - Artigos em Revistas Internacionais Com Arbitragem Científica)jmgt@uevora.ptm43708@alunos.uevora.pt304Ginja Teixeira, JorgeOliveira, Joãoinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-01-03T19:24:43Zoai:dspace.uevora.pt:10174/28379Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T01:18:20.199087Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Voltammetric Study of the Antihistamine Drug Bilastine: Anodic Characterization and Quantification Using a Reusable MWCNTs Modified Screen Printed Carbon Electrode |
title |
Voltammetric Study of the Antihistamine Drug Bilastine: Anodic Characterization and Quantification Using a Reusable MWCNTs Modified Screen Printed Carbon Electrode |
spellingShingle |
Voltammetric Study of the Antihistamine Drug Bilastine: Anodic Characterization and Quantification Using a Reusable MWCNTs Modified Screen Printed Carbon Electrode Ginja Teixeira, Jorge Antihistamine Bilastine Multi-walled carbon nanotubes (MWCNTs) Screen printed carbon electrode (SPCE) Voltammetric determination |
title_short |
Voltammetric Study of the Antihistamine Drug Bilastine: Anodic Characterization and Quantification Using a Reusable MWCNTs Modified Screen Printed Carbon Electrode |
title_full |
Voltammetric Study of the Antihistamine Drug Bilastine: Anodic Characterization and Quantification Using a Reusable MWCNTs Modified Screen Printed Carbon Electrode |
title_fullStr |
Voltammetric Study of the Antihistamine Drug Bilastine: Anodic Characterization and Quantification Using a Reusable MWCNTs Modified Screen Printed Carbon Electrode |
title_full_unstemmed |
Voltammetric Study of the Antihistamine Drug Bilastine: Anodic Characterization and Quantification Using a Reusable MWCNTs Modified Screen Printed Carbon Electrode |
title_sort |
Voltammetric Study of the Antihistamine Drug Bilastine: Anodic Characterization and Quantification Using a Reusable MWCNTs Modified Screen Printed Carbon Electrode |
author |
Ginja Teixeira, Jorge |
author_facet |
Ginja Teixeira, Jorge Oliveira, João |
author_role |
author |
author2 |
Oliveira, João |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Ginja Teixeira, Jorge Oliveira, João |
dc.subject.por.fl_str_mv |
Antihistamine Bilastine Multi-walled carbon nanotubes (MWCNTs) Screen printed carbon electrode (SPCE) Voltammetric determination |
topic |
Antihistamine Bilastine Multi-walled carbon nanotubes (MWCNTs) Screen printed carbon electrode (SPCE) Voltammetric determination |
description |
The anodic behaviour and the electroanalytical quantification of the second‐generation antihistamine bilastine (BIL) were investigated for the first time. A multi‐walled carbon nanotubes (MWCNTs) film‐coated screen printed carbon electrode (SPCE), as well as cyclic (CV) and linear sweep (LSV) voltammetry, were used for that purpose. The results showed that BIL undergoes an irreversible two‐electron oxidation process at the MWCNTs‐SPCE sensor. It was also found that the sensor can be reused after a simple and rapid reconditioning procedure. The proposed method was applied to the quantification of BIL in pharmaceutical formulations and spiked urine samples, and good recoveries were obtained. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-11-23T14:55:25Z 2020-11-23 2020-11-08T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10174/28379 https://doi.org/Jorge Ginja Teixeira, João Oliveira, Electroanalysis, 08 November 2020 https://doi.org/10.1002/elan.202060494 (10 pages) https://doi.org/http://dx.doi.org/10.1002/elan.202060494 http://hdl.handle.net/10174/28379 https://doi.org/10.1002/elan.202060494 |
url |
http://hdl.handle.net/10174/28379 https://doi.org/Jorge Ginja Teixeira, João Oliveira, Electroanalysis, 08 November 2020 https://doi.org/10.1002/elan.202060494 (10 pages) https://doi.org/http://dx.doi.org/10.1002/elan.202060494 https://doi.org/10.1002/elan.202060494 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
1521-4109 HERCULES - Laboratório HERCULES - Herança Cultural, Estudos e Salvaguarda (HERCULES - Publicações - Artigos em Revistas Internacionais Com Arbitragem Científica) jmgt@uevora.pt m43708@alunos.uevora.pt 304 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Wiley |
publisher.none.fl_str_mv |
Wiley |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799136664959844352 |