The effect of hemicylindrical disruptors on the cell free layer thickness in animal blood flows inside microchannels
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10174/29413 https://doi.org/10.1017/exp.2020.60 |
Resumo: | Blood-side resistance to oxygen transport in extracorporeal membrane blood oxygenators (MBO) depends on fluid mechanics governing the laminar flow in very narrow channels, particularly the hemodynamics controlling the cell free layer (CFL) built-up at solid/blood interfaces. The CFL thickness constitutes a barrier to oxygen transport from the membrane towards the erythrocytes. Interposing hemicylindrical CFL disruptors in animal blood flows inside rectangular microchannels, surrogate systems of MBO mimicking their hemodynamics, proved to be effective in reducing (ca. 20%) such thickness (desirable for MBO to increase oxygen transport rates to the erythrocytes). The blockage ratio (non-dimensional measure of the disruptor penetration into the flow) increase is also effective in reducing CFL thickness (ca. 10–20%), but at the cost of risking clot formation (undesirable for MBO) for disruptors with penetration lengths larger than their radius, due to large residence times of erythrocytes inside a low-velocity CFL formed at the disruptor/wall edge. |
id |
RCAP_ba7c95d2460c3d1dadc0ed91bfc6e9b7 |
---|---|
oai_identifier_str |
oai:dspace.uevora.pt:10174/29413 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
The effect of hemicylindrical disruptors on the cell free layer thickness in animal blood flows inside microchannelsFluid MechanicsBlood FlowMicrofluidicsBlood-side resistance to oxygen transport in extracorporeal membrane blood oxygenators (MBO) depends on fluid mechanics governing the laminar flow in very narrow channels, particularly the hemodynamics controlling the cell free layer (CFL) built-up at solid/blood interfaces. The CFL thickness constitutes a barrier to oxygen transport from the membrane towards the erythrocytes. Interposing hemicylindrical CFL disruptors in animal blood flows inside rectangular microchannels, surrogate systems of MBO mimicking their hemodynamics, proved to be effective in reducing (ca. 20%) such thickness (desirable for MBO to increase oxygen transport rates to the erythrocytes). The blockage ratio (non-dimensional measure of the disruptor penetration into the flow) increase is also effective in reducing CFL thickness (ca. 10–20%), but at the cost of risking clot formation (undesirable for MBO) for disruptors with penetration lengths larger than their radius, due to large residence times of erythrocytes inside a low-velocity CFL formed at the disruptor/wall edge.Cambridge University Press2021-03-26T13:16:31Z2021-03-262020-12-17T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10174/29413https://doi.org/10.1017/exp.2020.60http://hdl.handle.net/10174/29413https://doi.org/10.1017/exp.2020.60porndndgnsilva@uevora.ptViriatoSemiao@tecnico.ulisboa.pt449Dias, DuarteSampaio, DuarteSilva, GoncaloSemião, Viriatoinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-01-03T19:26:33Zoai:dspace.uevora.pt:10174/29413Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T01:19:04.759042Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
The effect of hemicylindrical disruptors on the cell free layer thickness in animal blood flows inside microchannels |
title |
The effect of hemicylindrical disruptors on the cell free layer thickness in animal blood flows inside microchannels |
spellingShingle |
The effect of hemicylindrical disruptors on the cell free layer thickness in animal blood flows inside microchannels Dias, Duarte Fluid Mechanics Blood Flow Microfluidics |
title_short |
The effect of hemicylindrical disruptors on the cell free layer thickness in animal blood flows inside microchannels |
title_full |
The effect of hemicylindrical disruptors on the cell free layer thickness in animal blood flows inside microchannels |
title_fullStr |
The effect of hemicylindrical disruptors on the cell free layer thickness in animal blood flows inside microchannels |
title_full_unstemmed |
The effect of hemicylindrical disruptors on the cell free layer thickness in animal blood flows inside microchannels |
title_sort |
The effect of hemicylindrical disruptors on the cell free layer thickness in animal blood flows inside microchannels |
author |
Dias, Duarte |
author_facet |
Dias, Duarte Sampaio, Duarte Silva, Goncalo Semião, Viriato |
author_role |
author |
author2 |
Sampaio, Duarte Silva, Goncalo Semião, Viriato |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Dias, Duarte Sampaio, Duarte Silva, Goncalo Semião, Viriato |
dc.subject.por.fl_str_mv |
Fluid Mechanics Blood Flow Microfluidics |
topic |
Fluid Mechanics Blood Flow Microfluidics |
description |
Blood-side resistance to oxygen transport in extracorporeal membrane blood oxygenators (MBO) depends on fluid mechanics governing the laminar flow in very narrow channels, particularly the hemodynamics controlling the cell free layer (CFL) built-up at solid/blood interfaces. The CFL thickness constitutes a barrier to oxygen transport from the membrane towards the erythrocytes. Interposing hemicylindrical CFL disruptors in animal blood flows inside rectangular microchannels, surrogate systems of MBO mimicking their hemodynamics, proved to be effective in reducing (ca. 20%) such thickness (desirable for MBO to increase oxygen transport rates to the erythrocytes). The blockage ratio (non-dimensional measure of the disruptor penetration into the flow) increase is also effective in reducing CFL thickness (ca. 10–20%), but at the cost of risking clot formation (undesirable for MBO) for disruptors with penetration lengths larger than their radius, due to large residence times of erythrocytes inside a low-velocity CFL formed at the disruptor/wall edge. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-12-17T00:00:00Z 2021-03-26T13:16:31Z 2021-03-26 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10174/29413 https://doi.org/10.1017/exp.2020.60 http://hdl.handle.net/10174/29413 https://doi.org/10.1017/exp.2020.60 |
url |
http://hdl.handle.net/10174/29413 https://doi.org/10.1017/exp.2020.60 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
nd nd gnsilva@uevora.pt ViriatoSemiao@tecnico.ulisboa.pt 449 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Cambridge University Press |
publisher.none.fl_str_mv |
Cambridge University Press |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799136672270516224 |