Thermomechanical analysis of cold formed steel sections
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10198/13938 |
Resumo: | This work presents an experimental study about cold formed steel elements submitted to compression loads. The sections analyzed are C and Z sections made of steel sheet with 1.5 and 2 [mm] thick and three different cross section heights. The compression tests were made at ambient and elevated temperatures. In both cases a pined support was developed and used. The member resistance at ambient temperature was determined by applying an increasing compression load until the member collapse was achieved. The fire tests were performed in a fire resistance furnace, using the same type of end supports, and a mechanical load given by a specific degree of utilization that is maintained constant during the fire test. These tests allow the determination of the fire resistance time and member critical temperature. The experimental results are compared with the ones obtained with the Eurocode simplified models. |
id |
RCAP_c0148afeae2810f7c1cd1e2de446504c |
---|---|
oai_identifier_str |
oai:bibliotecadigital.ipb.pt:10198/13938 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Thermomechanical analysis of cold formed steel sectionsFire resistanceExperimental testsCold formed sectionsThis work presents an experimental study about cold formed steel elements submitted to compression loads. The sections analyzed are C and Z sections made of steel sheet with 1.5 and 2 [mm] thick and three different cross section heights. The compression tests were made at ambient and elevated temperatures. In both cases a pined support was developed and used. The member resistance at ambient temperature was determined by applying an increasing compression load until the member collapse was achieved. The fire tests were performed in a fire resistance furnace, using the same type of end supports, and a mechanical load given by a specific degree of utilization that is maintained constant during the fire test. These tests allow the determination of the fire resistance time and member critical temperature. The experimental results are compared with the ones obtained with the Eurocode simplified models.Associação Portuguesa de Análise Experimental de TensõesBiblioteca Digital do IPBMesquita, L.M.R.Mendonça, MiguelRamos, RuiBarreira, LuísaPiloto, P.A.G.2017-01-31T09:58:50Z20162016-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10198/13938porMesquita, L.M.R.; Mendonça, Miguel; Ramos, Rui; Barreira, Luísa; Piloto, P.A.G. (2016). Thermomechanical analysis of cold formed steel sections. Mecânica Experimental, ISSN 1646-7078. 27, p. 75-841646-7078info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-21T10:32:55Zoai:bibliotecadigital.ipb.pt:10198/13938Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T23:03:54.046005Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Thermomechanical analysis of cold formed steel sections |
title |
Thermomechanical analysis of cold formed steel sections |
spellingShingle |
Thermomechanical analysis of cold formed steel sections Mesquita, L.M.R. Fire resistance Experimental tests Cold formed sections |
title_short |
Thermomechanical analysis of cold formed steel sections |
title_full |
Thermomechanical analysis of cold formed steel sections |
title_fullStr |
Thermomechanical analysis of cold formed steel sections |
title_full_unstemmed |
Thermomechanical analysis of cold formed steel sections |
title_sort |
Thermomechanical analysis of cold formed steel sections |
author |
Mesquita, L.M.R. |
author_facet |
Mesquita, L.M.R. Mendonça, Miguel Ramos, Rui Barreira, Luísa Piloto, P.A.G. |
author_role |
author |
author2 |
Mendonça, Miguel Ramos, Rui Barreira, Luísa Piloto, P.A.G. |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Biblioteca Digital do IPB |
dc.contributor.author.fl_str_mv |
Mesquita, L.M.R. Mendonça, Miguel Ramos, Rui Barreira, Luísa Piloto, P.A.G. |
dc.subject.por.fl_str_mv |
Fire resistance Experimental tests Cold formed sections |
topic |
Fire resistance Experimental tests Cold formed sections |
description |
This work presents an experimental study about cold formed steel elements submitted to compression loads. The sections analyzed are C and Z sections made of steel sheet with 1.5 and 2 [mm] thick and three different cross section heights. The compression tests were made at ambient and elevated temperatures. In both cases a pined support was developed and used. The member resistance at ambient temperature was determined by applying an increasing compression load until the member collapse was achieved. The fire tests were performed in a fire resistance furnace, using the same type of end supports, and a mechanical load given by a specific degree of utilization that is maintained constant during the fire test. These tests allow the determination of the fire resistance time and member critical temperature. The experimental results are compared with the ones obtained with the Eurocode simplified models. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016 2016-01-01T00:00:00Z 2017-01-31T09:58:50Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10198/13938 |
url |
http://hdl.handle.net/10198/13938 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
Mesquita, L.M.R.; Mendonça, Miguel; Ramos, Rui; Barreira, Luísa; Piloto, P.A.G. (2016). Thermomechanical analysis of cold formed steel sections. Mecânica Experimental, ISSN 1646-7078. 27, p. 75-84 1646-7078 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Associação Portuguesa de Análise Experimental de Tensões |
publisher.none.fl_str_mv |
Associação Portuguesa de Análise Experimental de Tensões |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799135285308555264 |