Simulação de dispositivos médicos em Android

Detalhes bibliográficos
Autor(a) principal: Pinto, André Miguel Bonjardim
Data de Publicação: 2018
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://hdl.handle.net/1822/79892
Resumo: Dissertação de mestrado em Engenharia Informática
id RCAP_cbcef38bf03fde40badeb1c5f5a79087
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/79892
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Simulação de dispositivos médicos em AndroidSimulation of medical devices in AndroidDispositivos médicosSimulaçãoMobilidadeTecnologiaAplicações móveisMedical devicesSimulationMobilityTechnologyMobile applicationsEngenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e InformáticaDissertação de mestrado em Engenharia InformáticaHoje em dia, em qualquer unidade de saúde (hospitais, centros de saúde, clínicas, etc.), existem diversos equipamentos médicos, cada um com a sua complexidade. Alguns destes equipamentos são cruciais para o tratamento de pacientes e requerem que a interação das equipas médicas com os mesmos seja precisa e exata, correndo-se o risco de, ao mínimo erro, causar danos fatais ao paciente. Todos os dias, pelo mundo fora, ocorrem erros com dispositivos médicos e de dispositivos médicos. Os erros com dispositivos médicos são causados devido a algum erro de utilização: uma sequência errada de botões, informação inserida em campos errados, falta de atenção às unidades de medida, etc. Em alguns casos, estes erros ocorrem devido à falta de interação de um profissional com certo dispositivo. Esta interação, pode ser reduzida, muitas vezes, devido a um dispositivo ter um custo elevado que não é justificável para um dispositivo disponível somente para testes. Assim, as equipas médicas apenas interagem com o dispositivo quando um paciente precisa de cuidados médicos, o que pode ser perigoso caso um médico ou enfermeiro não esteja familiarizado(a) com o dispositivo. Por outro lado, os erros de dispositivos médicos são causados por alguma falha no próprio dispositivo, não podendo ser evitada pelas equipas médicas, e que pode dever-se a uma má programação ou construção do dispositivo. Uma solução, para a prevenção de erros na utilização de dispositivos médicos, passa pela simulação de dispositivos médicos, de modo a que os dispositivos possam ser tanto testados para prevenir eventuais erros de software na interface de utilizador que possam existir, como usados para a formação e treino de pessoal médico para diminuir os erros provocados na interação com os dispositivos. A presente proposta de dissertação, no âmbito do Mestrado Integrado em Engenharia Informática, visa tirar partido das aplicações móveis para a simulação de dispositivos médicos com que não podemos interagir todos os dias. Com a criação destas simulações será possível ter inúmeras virtualizações de dispositivos médicos presentes nas unidades de saúde (centros de saúde, enfermarias, hospitais, clínicas, etc.) ao alcance de um tablet ou smartphone. Isto irá também permitir uma maior mobilidade para simulações, permitindo aos utilizadores levar a cabo um treino diário ou semanal com um dispositivo simulado. Passa também a haver uma maior mobilidade para quem desenvolve e cria protótipos de dispositivos inovadores, sendo que podemos apresentar a aplicação ao público alvo e ter um feedback instantâneo sobre os aspetos positivos e negativos do protótipo, bem como novas ideias para futuras funcionalidades que possam ser adicionadas ao protótipo.Nowadays, in any health unit (hospitals, health centers, clinics, etc.), there are several medical equipment, each one with its complexity. Some of these equipment are crucial for treatment of patients and require that the interaction of medical teams with them is precise and accurate, at the risk of causing fatal injuries to the patient at the slightest error. Use errors with medical devices can be caused by human error: a wrong sequence of buttons, information entered in wrong fields, lack of attention to units of measurement, etc. Various research studies revealed that these use errors are often caused by design errors in the user interface of the device, rather than negligence or lack of training of clinical practitioners. Simulation of medical devices is a way to facilitate early detection of latent design errors. The same simulations can also be used for training of end users, to help them identify and avoid latent design problems that might affect a device, while waiting that the manufacturer fixes the problem. The present dissertation proposal, within the scope of the Integrated Master in Computer Science, aims to take advantage of the mobile applications for the simulation of medical devices with which we cannot interact every day. This interaction at the training level can be reduced, often because a device has a high cost and is not justifiable for a test-only device. With the creation of these simulations it will be possible to have numerous virtualizations of medical devices present in health facilities within a tablet or smartphone. This will also allow greater mobility for simulations, allowing practitioners to carry out daily or weekly training with a simulated device. It also gives a great advantage for those who develop and create prototypes of innovative devices. They can present the application to the target audience and have instant feedback on the positive and negative aspects of the prototype, as well as new ideas for future functionalities that can be added to the prototype.Campos, José C.Masci, PaoloUniversidade do MinhoPinto, André Miguel Bonjardim2018-12-142018-12-14T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttps://hdl.handle.net/1822/79892por203017765info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-12-09T01:20:53Zoai:repositorium.sdum.uminho.pt:1822/79892Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:37:52.960540Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Simulação de dispositivos médicos em Android
Simulation of medical devices in Android
title Simulação de dispositivos médicos em Android
spellingShingle Simulação de dispositivos médicos em Android
Pinto, André Miguel Bonjardim
Dispositivos médicos
Simulação
Mobilidade
Tecnologia
Aplicações móveis
Medical devices
Simulation
Mobility
Technology
Mobile applications
Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
title_short Simulação de dispositivos médicos em Android
title_full Simulação de dispositivos médicos em Android
title_fullStr Simulação de dispositivos médicos em Android
title_full_unstemmed Simulação de dispositivos médicos em Android
title_sort Simulação de dispositivos médicos em Android
author Pinto, André Miguel Bonjardim
author_facet Pinto, André Miguel Bonjardim
author_role author
dc.contributor.none.fl_str_mv Campos, José C.
Masci, Paolo
Universidade do Minho
dc.contributor.author.fl_str_mv Pinto, André Miguel Bonjardim
dc.subject.por.fl_str_mv Dispositivos médicos
Simulação
Mobilidade
Tecnologia
Aplicações móveis
Medical devices
Simulation
Mobility
Technology
Mobile applications
Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
topic Dispositivos médicos
Simulação
Mobilidade
Tecnologia
Aplicações móveis
Medical devices
Simulation
Mobility
Technology
Mobile applications
Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
description Dissertação de mestrado em Engenharia Informática
publishDate 2018
dc.date.none.fl_str_mv 2018-12-14
2018-12-14T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1822/79892
url https://hdl.handle.net/1822/79892
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv 203017765
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132913960222720