In vitro comparative study of the surface properties of materials for removable prosthetic bases

Detalhes bibliográficos
Autor(a) principal: Sampaio-Fernandes,Margarida
Data de Publicação: 2022
Outros Autores: Ferreira Júnior,Cláudio, Oliveira,Susana João, Martins,Ramiro Carneiro, Sampaio-Fernandes,João Carlos, Figueiral,Maria Helena
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-28902022000300117
Resumo: Abstract Objectives: This work aimed to evaluate and compare the surface roughness, contact angle, and C. albicans adhesion in three materials for removable denture bases: polymethylmethacrylate and the thermoplastic resins polypropylene and polyolefin. Methods: Nine samples were manufactured, three of each material (n=3): polypropylene, polyolefin, and polymethylmethacrylate (control group). The thermoplastic resins were fabricated by injection technique and the polymethylmethacrylate by compression technique. After laboratory polishing, the surface roughness (Ra and Rz) was assessed with the 3D optical roughness meter NPFLEX, and the contact angle was measured with the optical tensiometer Contact angle system OCA15. C. albicans adhesion was assessed through colony- forming unit assays (n=9). ANOVA and Kruskal-Wallis tests were done to compare groups, considering a significance level of 0.05. Results: All values obtained for the control group were lower than those obtained for the thermoplastic resins. Statistically significant differences were found: for Ra between polypropylene (0.15±0.072 μm) and polymethylmethacrylate (0.03±0.006 μm) (p=0.045); for the contact angle between the three groups (p<0.001) - polymethylmethacrylate (26.57±6.719°), polypropylene (57.57±11.098°), and polyolefin (69.06±8.955°); and for C. albicans adhesion between polymethylmethacrylate and polypropylene (p=0.007) and polymethylmethacrylate and polyolefin (p=0.013). Conclusions: In the tested conditions and for the materials assessed, polymethylmethacrylate showed the lowest roughness, contact angle, and C. albicans adhesion, thus exhibiting better properties for removable denture bases than the thermoplastic materials.
id RCAP_d47ffa38b26aee55aac3a9410b21d497
oai_identifier_str oai:scielo:S1646-28902022000300117
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling In vitro comparative study of the surface properties of materials for removable prosthetic basesCandida albicansContact angleDenture basePolymethylmethacrylatePolyolefinPolypropyleneSurface roughnessAbstract Objectives: This work aimed to evaluate and compare the surface roughness, contact angle, and C. albicans adhesion in three materials for removable denture bases: polymethylmethacrylate and the thermoplastic resins polypropylene and polyolefin. Methods: Nine samples were manufactured, three of each material (n=3): polypropylene, polyolefin, and polymethylmethacrylate (control group). The thermoplastic resins were fabricated by injection technique and the polymethylmethacrylate by compression technique. After laboratory polishing, the surface roughness (Ra and Rz) was assessed with the 3D optical roughness meter NPFLEX, and the contact angle was measured with the optical tensiometer Contact angle system OCA15. C. albicans adhesion was assessed through colony- forming unit assays (n=9). ANOVA and Kruskal-Wallis tests were done to compare groups, considering a significance level of 0.05. Results: All values obtained for the control group were lower than those obtained for the thermoplastic resins. Statistically significant differences were found: for Ra between polypropylene (0.15±0.072 μm) and polymethylmethacrylate (0.03±0.006 μm) (p=0.045); for the contact angle between the three groups (p<0.001) - polymethylmethacrylate (26.57±6.719°), polypropylene (57.57±11.098°), and polyolefin (69.06±8.955°); and for C. albicans adhesion between polymethylmethacrylate and polypropylene (p=0.007) and polymethylmethacrylate and polyolefin (p=0.013). Conclusions: In the tested conditions and for the materials assessed, polymethylmethacrylate showed the lowest roughness, contact angle, and C. albicans adhesion, thus exhibiting better properties for removable denture bases than the thermoplastic materials.Sociedade Portuguesa de Estomatologia e Medicina Dentária2022-09-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-28902022000300117Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial v.63 n.3 2022reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-28902022000300117Sampaio-Fernandes,MargaridaFerreira Júnior,CláudioOliveira,Susana JoãoMartins,Ramiro CarneiroSampaio-Fernandes,João CarlosFigueiral,Maria Helenainfo:eu-repo/semantics/openAccess2024-02-06T17:21:11Zoai:scielo:S1646-28902022000300117Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:28:18.271140Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv In vitro comparative study of the surface properties of materials for removable prosthetic bases
title In vitro comparative study of the surface properties of materials for removable prosthetic bases
spellingShingle In vitro comparative study of the surface properties of materials for removable prosthetic bases
Sampaio-Fernandes,Margarida
Candida albicans
Contact angle
Denture base
Polymethylmethacrylate
Polyolefin
Polypropylene
Surface roughness
title_short In vitro comparative study of the surface properties of materials for removable prosthetic bases
title_full In vitro comparative study of the surface properties of materials for removable prosthetic bases
title_fullStr In vitro comparative study of the surface properties of materials for removable prosthetic bases
title_full_unstemmed In vitro comparative study of the surface properties of materials for removable prosthetic bases
title_sort In vitro comparative study of the surface properties of materials for removable prosthetic bases
author Sampaio-Fernandes,Margarida
author_facet Sampaio-Fernandes,Margarida
Ferreira Júnior,Cláudio
Oliveira,Susana João
Martins,Ramiro Carneiro
Sampaio-Fernandes,João Carlos
Figueiral,Maria Helena
author_role author
author2 Ferreira Júnior,Cláudio
Oliveira,Susana João
Martins,Ramiro Carneiro
Sampaio-Fernandes,João Carlos
Figueiral,Maria Helena
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Sampaio-Fernandes,Margarida
Ferreira Júnior,Cláudio
Oliveira,Susana João
Martins,Ramiro Carneiro
Sampaio-Fernandes,João Carlos
Figueiral,Maria Helena
dc.subject.por.fl_str_mv Candida albicans
Contact angle
Denture base
Polymethylmethacrylate
Polyolefin
Polypropylene
Surface roughness
topic Candida albicans
Contact angle
Denture base
Polymethylmethacrylate
Polyolefin
Polypropylene
Surface roughness
description Abstract Objectives: This work aimed to evaluate and compare the surface roughness, contact angle, and C. albicans adhesion in three materials for removable denture bases: polymethylmethacrylate and the thermoplastic resins polypropylene and polyolefin. Methods: Nine samples were manufactured, three of each material (n=3): polypropylene, polyolefin, and polymethylmethacrylate (control group). The thermoplastic resins were fabricated by injection technique and the polymethylmethacrylate by compression technique. After laboratory polishing, the surface roughness (Ra and Rz) was assessed with the 3D optical roughness meter NPFLEX, and the contact angle was measured with the optical tensiometer Contact angle system OCA15. C. albicans adhesion was assessed through colony- forming unit assays (n=9). ANOVA and Kruskal-Wallis tests were done to compare groups, considering a significance level of 0.05. Results: All values obtained for the control group were lower than those obtained for the thermoplastic resins. Statistically significant differences were found: for Ra between polypropylene (0.15±0.072 μm) and polymethylmethacrylate (0.03±0.006 μm) (p=0.045); for the contact angle between the three groups (p<0.001) - polymethylmethacrylate (26.57±6.719°), polypropylene (57.57±11.098°), and polyolefin (69.06±8.955°); and for C. albicans adhesion between polymethylmethacrylate and polypropylene (p=0.007) and polymethylmethacrylate and polyolefin (p=0.013). Conclusions: In the tested conditions and for the materials assessed, polymethylmethacrylate showed the lowest roughness, contact angle, and C. albicans adhesion, thus exhibiting better properties for removable denture bases than the thermoplastic materials.
publishDate 2022
dc.date.none.fl_str_mv 2022-09-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-28902022000300117
url http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-28902022000300117
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-28902022000300117
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Portuguesa de Estomatologia e Medicina Dentária
publisher.none.fl_str_mv Sociedade Portuguesa de Estomatologia e Medicina Dentária
dc.source.none.fl_str_mv Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial v.63 n.3 2022
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799137353050095616