Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plants

Detalhes bibliográficos
Autor(a) principal: Radia, AIT EL CADI
Data de Publicação: 2018
Tipo de documento: Artigo
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10174/31755
https://doi.org/S. Bouaddi, A. Fernández-García, A. Ihlal, R. Ait El Cadi, L. Álvarez-Rodrigo, Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plants, Sol. Energy. 166 (2018) 422–431. https://doi.org/10.1016/J.SOLENER.2018.03.070.
https://doi.org/10.1016/j.solener.2018.03.070
Resumo: The task of cleaning reflectors is a widely adopted strategy to handle the soiling in concentrated solar power (CSP) plants. The dynamics of the soiling of frequently cleaned mirrors is dependent on many factors such as the cleaning method, its frequency and the seasonal soiling rate. This study proposes a new approach to model the soiling of regularly cleaned reflectors instead of the inaccurate methods undermining the CSP yield by using fixed reflectance assumptions. Markov switching (MS) regime, which is a non linear time series approach where parameters are allowed to switch between the regimes, are applied on the reflectance data of second surface silvered-glass mirrors, exposed at the Plataforma Solar de Almería (PSA) in Spain during two years and cleaned biweekly using high pressure demineralized water. The nonlinearities typically exhibited by such reflectance time series are successfully modeled by accounting for two regimes, a soiled and a clean regime, and incorporating various parameters (rain, washing cycle, and lagged autoregressive terms) in the suggested MS models. Based on the information criteria and the diagnostic of the models residuals, the best model has a switching normalized reflectance mean of 0.944 during the clean regime versus 0.688 during the soiled regime, in addition to one fixed lag autoregressive term. In order to evaluate the adequacy of the proposed model versus the traditional approach, which uses fixed reflectance as input for estimating CSP plants yield, four reflectance scenarios were studied by simulating the output of a 30 MWe plant using TRNSYS© (TRaNsientSYstem Simulation) program. The first and the second scenarios used the time series of the measured and fitted model reflectance data, while the third and the forth scenarios used fixed inputs (a maximum and a yearly average reflectance). The comparison of the simulation results showed that adopting the innovative proposed concept of switching regimes results in very good performance, especially in the soiled regime during which the simplistic reflectance considerations, which ignore the soiling dynamics and the applied washing cycle, undermine the generated power.
id RCAP_dc7ae27ad6ce44a08102ba9949a4b76a
oai_identifier_str oai:dspace.uevora.pt:10174/31755
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plantsCSPSilvered-glass mirrorReflectanceSoilingMarkov switchingTRNSYSThe task of cleaning reflectors is a widely adopted strategy to handle the soiling in concentrated solar power (CSP) plants. The dynamics of the soiling of frequently cleaned mirrors is dependent on many factors such as the cleaning method, its frequency and the seasonal soiling rate. This study proposes a new approach to model the soiling of regularly cleaned reflectors instead of the inaccurate methods undermining the CSP yield by using fixed reflectance assumptions. Markov switching (MS) regime, which is a non linear time series approach where parameters are allowed to switch between the regimes, are applied on the reflectance data of second surface silvered-glass mirrors, exposed at the Plataforma Solar de Almería (PSA) in Spain during two years and cleaned biweekly using high pressure demineralized water. The nonlinearities typically exhibited by such reflectance time series are successfully modeled by accounting for two regimes, a soiled and a clean regime, and incorporating various parameters (rain, washing cycle, and lagged autoregressive terms) in the suggested MS models. Based on the information criteria and the diagnostic of the models residuals, the best model has a switching normalized reflectance mean of 0.944 during the clean regime versus 0.688 during the soiled regime, in addition to one fixed lag autoregressive term. In order to evaluate the adequacy of the proposed model versus the traditional approach, which uses fixed reflectance as input for estimating CSP plants yield, four reflectance scenarios were studied by simulating the output of a 30 MWe plant using TRNSYS© (TRaNsientSYstem Simulation) program. The first and the second scenarios used the time series of the measured and fitted model reflectance data, while the third and the forth scenarios used fixed inputs (a maximum and a yearly average reflectance). The comparison of the simulation results showed that adopting the innovative proposed concept of switching regimes results in very good performance, especially in the soiled regime during which the simplistic reflectance considerations, which ignore the soiling dynamics and the applied washing cycle, undermine the generated power.Elsevier2022-04-20T14:32:31Z2022-04-202018-04-05T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10174/31755https://doi.org/S. Bouaddi, A. Fernández-García, A. Ihlal, R. Ait El Cadi, L. Álvarez-Rodrigo, Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plants, Sol. Energy. 166 (2018) 422–431. https://doi.org/10.1016/J.SOLENER.2018.03.070.https://doi.org/10.1016/j.solener.2018.03.070http://hdl.handle.net/10174/31755https://doi.org/10.1016/j.solener.2018.03.070porradia.aitelcadi@uevora.pt275Radia, AIT EL CADIinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-01-03T19:31:37Zoai:dspace.uevora.pt:10174/31755Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T01:20:50.459739Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plants
title Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plants
spellingShingle Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plants
Radia, AIT EL CADI
CSP
Silvered-glass mirror
Reflectance
SoilingMarkov switching
TRNSYS
title_short Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plants
title_full Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plants
title_fullStr Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plants
title_full_unstemmed Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plants
title_sort Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plants
author Radia, AIT EL CADI
author_facet Radia, AIT EL CADI
author_role author
dc.contributor.author.fl_str_mv Radia, AIT EL CADI
dc.subject.por.fl_str_mv CSP
Silvered-glass mirror
Reflectance
SoilingMarkov switching
TRNSYS
topic CSP
Silvered-glass mirror
Reflectance
SoilingMarkov switching
TRNSYS
description The task of cleaning reflectors is a widely adopted strategy to handle the soiling in concentrated solar power (CSP) plants. The dynamics of the soiling of frequently cleaned mirrors is dependent on many factors such as the cleaning method, its frequency and the seasonal soiling rate. This study proposes a new approach to model the soiling of regularly cleaned reflectors instead of the inaccurate methods undermining the CSP yield by using fixed reflectance assumptions. Markov switching (MS) regime, which is a non linear time series approach where parameters are allowed to switch between the regimes, are applied on the reflectance data of second surface silvered-glass mirrors, exposed at the Plataforma Solar de Almería (PSA) in Spain during two years and cleaned biweekly using high pressure demineralized water. The nonlinearities typically exhibited by such reflectance time series are successfully modeled by accounting for two regimes, a soiled and a clean regime, and incorporating various parameters (rain, washing cycle, and lagged autoregressive terms) in the suggested MS models. Based on the information criteria and the diagnostic of the models residuals, the best model has a switching normalized reflectance mean of 0.944 during the clean regime versus 0.688 during the soiled regime, in addition to one fixed lag autoregressive term. In order to evaluate the adequacy of the proposed model versus the traditional approach, which uses fixed reflectance as input for estimating CSP plants yield, four reflectance scenarios were studied by simulating the output of a 30 MWe plant using TRNSYS© (TRaNsientSYstem Simulation) program. The first and the second scenarios used the time series of the measured and fitted model reflectance data, while the third and the forth scenarios used fixed inputs (a maximum and a yearly average reflectance). The comparison of the simulation results showed that adopting the innovative proposed concept of switching regimes results in very good performance, especially in the soiled regime during which the simplistic reflectance considerations, which ignore the soiling dynamics and the applied washing cycle, undermine the generated power.
publishDate 2018
dc.date.none.fl_str_mv 2018-04-05T00:00:00Z
2022-04-20T14:32:31Z
2022-04-20
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10174/31755
https://doi.org/S. Bouaddi, A. Fernández-García, A. Ihlal, R. Ait El Cadi, L. Álvarez-Rodrigo, Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plants, Sol. Energy. 166 (2018) 422–431. https://doi.org/10.1016/J.SOLENER.2018.03.070.
https://doi.org/10.1016/j.solener.2018.03.070
http://hdl.handle.net/10174/31755
https://doi.org/10.1016/j.solener.2018.03.070
url http://hdl.handle.net/10174/31755
https://doi.org/S. Bouaddi, A. Fernández-García, A. Ihlal, R. Ait El Cadi, L. Álvarez-Rodrigo, Modeling and simulation of the soiling dynamics of frequently cleaned reflectors in CSP plants, Sol. Energy. 166 (2018) 422–431. https://doi.org/10.1016/J.SOLENER.2018.03.070.
https://doi.org/10.1016/j.solener.2018.03.070
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv radia.aitelcadi@uevora.pt
275
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799136689640177664