Permeability of Paint Films towards Chloride Ion
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://hdl.handle.net/10216/67678 |
Resumo: | Art apparatus for determining tire permeability of paint films towards chloride ion is described. This set-lip implements tire time-lag method and consists of a permeation cell made tip of two chambers divided by a supported paint film. The upper chamber contains air aqueous sodium chloride solution and tire lower one, water. The permeability is obtained front the conductivity history read at tire lower chamber. Osmotic pressure issue is addressed and tire reproducibility of the results reported. The time-lag method is not described in any standard. The requirement concerning "surface protection systems for concrete" for chloride ion permeability is not quantified in prEN 1504-2. The standard establishes that this requirement is "subject to national standards and national regulations" but when tire capillary adsorption of water is lower than 0.01 kg(m(2)h(05)) the diffusion of chloride ion is not to be expected. Some experimental results prove this is not correct and, in Portugal, the National Laboratory of Civil Engineering (LNEC) has proposed a threshold permeability value of 10(-14) m(2)/sec for coatings claiming to be corrosion protective. |
id |
RCAP_dc7c24c2e003d061576805d615824e5c |
---|---|
oai_identifier_str |
oai:repositorio-aberto.up.pt:10216/67678 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Permeability of Paint Films towards Chloride IonTecnologia química, Outras ciências da engenharia e tecnologiasChemical technology, Other engineering and technologiesArt apparatus for determining tire permeability of paint films towards chloride ion is described. This set-lip implements tire time-lag method and consists of a permeation cell made tip of two chambers divided by a supported paint film. The upper chamber contains air aqueous sodium chloride solution and tire lower one, water. The permeability is obtained front the conductivity history read at tire lower chamber. Osmotic pressure issue is addressed and tire reproducibility of the results reported. The time-lag method is not described in any standard. The requirement concerning "surface protection systems for concrete" for chloride ion permeability is not quantified in prEN 1504-2. The standard establishes that this requirement is "subject to national standards and national regulations" but when tire capillary adsorption of water is lower than 0.01 kg(m(2)h(05)) the diffusion of chloride ion is not to be expected. Some experimental results prove this is not correct and, in Portugal, the National Laboratory of Civil Engineering (LNEC) has proposed a threshold permeability value of 10(-14) m(2)/sec for coatings claiming to be corrosion protective.20062006-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/10216/67678engC. CarneiroF. OliveiraJ. NogueiraA. Mendesinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-29T13:54:05Zoai:repositorio-aberto.up.pt:10216/67678Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T23:50:12.996171Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Permeability of Paint Films towards Chloride Ion |
title |
Permeability of Paint Films towards Chloride Ion |
spellingShingle |
Permeability of Paint Films towards Chloride Ion C. Carneiro Tecnologia química, Outras ciências da engenharia e tecnologias Chemical technology, Other engineering and technologies |
title_short |
Permeability of Paint Films towards Chloride Ion |
title_full |
Permeability of Paint Films towards Chloride Ion |
title_fullStr |
Permeability of Paint Films towards Chloride Ion |
title_full_unstemmed |
Permeability of Paint Films towards Chloride Ion |
title_sort |
Permeability of Paint Films towards Chloride Ion |
author |
C. Carneiro |
author_facet |
C. Carneiro F. Oliveira J. Nogueira A. Mendes |
author_role |
author |
author2 |
F. Oliveira J. Nogueira A. Mendes |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
C. Carneiro F. Oliveira J. Nogueira A. Mendes |
dc.subject.por.fl_str_mv |
Tecnologia química, Outras ciências da engenharia e tecnologias Chemical technology, Other engineering and technologies |
topic |
Tecnologia química, Outras ciências da engenharia e tecnologias Chemical technology, Other engineering and technologies |
description |
Art apparatus for determining tire permeability of paint films towards chloride ion is described. This set-lip implements tire time-lag method and consists of a permeation cell made tip of two chambers divided by a supported paint film. The upper chamber contains air aqueous sodium chloride solution and tire lower one, water. The permeability is obtained front the conductivity history read at tire lower chamber. Osmotic pressure issue is addressed and tire reproducibility of the results reported. The time-lag method is not described in any standard. The requirement concerning "surface protection systems for concrete" for chloride ion permeability is not quantified in prEN 1504-2. The standard establishes that this requirement is "subject to national standards and national regulations" but when tire capillary adsorption of water is lower than 0.01 kg(m(2)h(05)) the diffusion of chloride ion is not to be expected. Some experimental results prove this is not correct and, in Portugal, the National Laboratory of Civil Engineering (LNEC) has proposed a threshold permeability value of 10(-14) m(2)/sec for coatings claiming to be corrosion protective. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006 2006-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/10216/67678 |
url |
https://hdl.handle.net/10216/67678 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799135821820854272 |