Técnicas de controlo avançadas na eficiência de um sistema térmico

Detalhes bibliográficos
Autor(a) principal: Clemente, Frederico Miguel Benito
Data de Publicação: 2016
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.21/7084
Resumo: Trabalho final de mestrado para obtenção do grau de Mestre em Engenharia Mecânica
id RCAP_e20857249b085ef48298503e27211b5c
oai_identifier_str oai:repositorio.ipl.pt:10400.21/7084
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Técnicas de controlo avançadas na eficiência de um sistema térmicoAquecimentoHeatingVentilação e ar condicionado (AVAC)Ventilation and aiir conditioning (HVAC)ControloControlControlador PIDPID controllerLógica FuzzyFuzzy logicUnidade de tratamento de ar (UTA)Air handling unit (AHU)Trabalho final de mestrado para obtenção do grau de Mestre em Engenharia MecânicaA presente dissertação debruça-se sobre a eficiência energética dos sistemas de AVAC, estudand oa introdução de técnicas de controlo avançadas naqueles equipamentos, mais concretamente, nas unidades de tratamento de ar. Para tal, foi projectado um sistema constituído por uma unidade de tratamento de ar, um controlador e um espaço hipotético. Este espaço tem o objectivo de simular os ganhos e perdas térmicos de um local definido através de determinados parâmetros. Os ensaios foram realizados num modelo simplificado de uma unidade de tratamento de ar, integrando apenas uma bateria de arrefecimento e funcionando com um caudal de 100% de ar novo, com recurso ao software Simulink do MATLAB. Numa primeira fase, o estudo consiste na comparação entre dois tipos de controladores, o PID e o Fuzzy, dividido por quatro grupos de simulação. Os grupos de análise consistem: Numa simulação com um caudal de ar de 300 l/s, dado um degrau unitário e uma temperatura exterior de 28 o C; Numa simulação com um regime de caudal variável (de 375 l/s, 225 l/s e 75 l/s) e nas mesmas condições de temperatura e degrau unitário da anterior; Numa simulação, com um setpoint fixo, uma temperatura exterior variável e um caudal de ar constante, estratificado nos caudais de 75 l/s, 150 l/s, 225 l/s, 300 l/s, 375 l/s e 450 l/s; Numa simulação com caudal de ar variável, controlado pelo sistema de controlo, temperatura exterior variável e setpoint constante. Posteriormente, concebe-se três versões diferentes do controlador Fuzzy, integradas num sistema SIMO, para efectuar o estudo comparativo, submetendo-as às mesmas condições de simulação (temperatura exterior variável e setpoint constante). Nas simulações de um degrau unitário com caudais de ar constante e variável, verificou-se que a resposta do controlador Fuzzy, atinge a estacionariedade mais cedo que o controlador PID. No entanto, no regime transiente, verifica-se uma maior oscilação em torno do valor final. Na simulação com caudal de ar variável, constata-se, que o sistema regulado pelo controlador Fuzzy, tem um menor consumo energético, contudo permite uma maior oscilação da temperatura no interior do espaço. Na simulação a temperatura exterior variável e caudal de ar constante, não são evidentes as vantagens da utilização de um sistema em detrimento do outro, pois observa-se por um lado, grandes períodos de saturação no sinal de saída do controlador PID. Mas por outro, ambas as acções de controlo, Fuzzy e PID, demonstram, um aumento da amplitude e da oscilação em torno do valor final, em função do incremento do caudal de ar. A simulação a caudal de ar e temperatura exterior variáveis, evidenciou as vantagens do controlador Fuzzy face ao controlo clássico, nomeadamente por demonstrar uma acção de controlo mais estável, e um consumo energético menor. Por último, na simulação comparativa entre versões, constata-se as vantagens da versão 3 comparativamente às restantes, principalmente pela estabilidade apresentada na regulação da temperatura na zona e pelo menor consumo energético global da unidade.Abstract: This dissertation focuses the energy efficiency of HVAC systems, because this is an important part of energy consumption in buildings, by studying the introduction of advanced control techniques in those devices, more specifically, in the air handling units. Of such, a system was designed consisting of an air handling unit, a controller and a hypothetical space. This space aims to simulate the thermal gains and losses of a location defined by certain parameters. The assays were performed on a simplified model integrating only one cooling battery and operating at a flow rate of 100% fresh air, using the software Simulink MATLAB Initially, the study is the comparison between two types of controllers, PID and Fuzzy, divided by four simulation groups. The analysis groups consist of: In a simulation with a 300 l/s air flow, given a unit step and an outdoor temperature of 28 C; In a simulation with a variable flow system (375 l/s, 225 l/s and 75 l/s) and under the same conditions of temperature and unit step, of the previous simulation; In a simulation, with a fixed setpoint, an external temperature variable and constant air flow, stratified in 75 l/s, 150 l/s, 225 l/s, 300 l/s, 375 l/s and 450 l/s; In a simulation with variable air flow, controlled by the control system, outside temperature variable and constant setpoint. Later, conceived three different versions of the fuzzy controller, integrated in a SIMO system, to carry out a comparative study, subjecting them, to the same simulation conditions (outside temperature variable and constant setpoint). In simulations of a unit step with constant and variable air flow rates, it was found that the response of the Fuzzy controller achieves the stationarity earlier than the PID controller. However, in the transiente regime, there is a greater oscillation around the target value. In the simulation with variable air flow, it is noted that the system controlled by the Fuzzy controller has a lower energy consumption, however allows a greater temperature oscillation within the space. In the simulation, outside temperature variable and constant flow of air, are not evident the advan-tages of using one system over another, as observed by the extended periods of saturation in the PID controller output. But otherwise, both control actions, Fuzzy and PID demonstrate an increase of the amplitude and oscillation around the final value, due the increase of airflow. The simulation, air flow and outdoor temperature variables, showed the advantages of the Fuzzy controller over the classic controller, demonstrating a more stable control action, and lower energy consumption. Finally, the comparative simulation between versions, notes the advantages of version 3 compared to the other, especially in the stability presented, on the regulation of temperature in the zone, and the lower overall power consumption of the unit.Instituto Superior de Engenharia de LisboaSilva, Pedro Miguel AbreuCasaca, Cláudia Sofia Séneca da LuzRCIPLClemente, Frederico Miguel Benito2017-05-26T18:46:07Z2016-12-022016-12-02T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10400.21/7084TID:201702614porCLEMENTE, Frederico Miguel Benito - Técnicas de controlo avançadas na eficiência de um sistema térmico. Lisboa: Instituto Superior de Engenharia de Lisboa, 2016. Dissertação de mestrado.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-03T09:52:41Zoai:repositorio.ipl.pt:10400.21/7084Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:16:06.592163Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Técnicas de controlo avançadas na eficiência de um sistema térmico
title Técnicas de controlo avançadas na eficiência de um sistema térmico
spellingShingle Técnicas de controlo avançadas na eficiência de um sistema térmico
Clemente, Frederico Miguel Benito
Aquecimento
Heating
Ventilação e ar condicionado (AVAC)
Ventilation and aiir conditioning (HVAC)
Controlo
Control
Controlador PID
PID controller
Lógica Fuzzy
Fuzzy logic
Unidade de tratamento de ar (UTA)
Air handling unit (AHU)
title_short Técnicas de controlo avançadas na eficiência de um sistema térmico
title_full Técnicas de controlo avançadas na eficiência de um sistema térmico
title_fullStr Técnicas de controlo avançadas na eficiência de um sistema térmico
title_full_unstemmed Técnicas de controlo avançadas na eficiência de um sistema térmico
title_sort Técnicas de controlo avançadas na eficiência de um sistema térmico
author Clemente, Frederico Miguel Benito
author_facet Clemente, Frederico Miguel Benito
author_role author
dc.contributor.none.fl_str_mv Silva, Pedro Miguel Abreu
Casaca, Cláudia Sofia Séneca da Luz
RCIPL
dc.contributor.author.fl_str_mv Clemente, Frederico Miguel Benito
dc.subject.por.fl_str_mv Aquecimento
Heating
Ventilação e ar condicionado (AVAC)
Ventilation and aiir conditioning (HVAC)
Controlo
Control
Controlador PID
PID controller
Lógica Fuzzy
Fuzzy logic
Unidade de tratamento de ar (UTA)
Air handling unit (AHU)
topic Aquecimento
Heating
Ventilação e ar condicionado (AVAC)
Ventilation and aiir conditioning (HVAC)
Controlo
Control
Controlador PID
PID controller
Lógica Fuzzy
Fuzzy logic
Unidade de tratamento de ar (UTA)
Air handling unit (AHU)
description Trabalho final de mestrado para obtenção do grau de Mestre em Engenharia Mecânica
publishDate 2016
dc.date.none.fl_str_mv 2016-12-02
2016-12-02T00:00:00Z
2017-05-26T18:46:07Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.21/7084
TID:201702614
url http://hdl.handle.net/10400.21/7084
identifier_str_mv TID:201702614
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv CLEMENTE, Frederico Miguel Benito - Técnicas de controlo avançadas na eficiência de um sistema térmico. Lisboa: Instituto Superior de Engenharia de Lisboa, 2016. Dissertação de mestrado.
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Instituto Superior de Engenharia de Lisboa
publisher.none.fl_str_mv Instituto Superior de Engenharia de Lisboa
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133421052624896