Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004 |
Resumo: | Four torsemide-selective electrodes all on solid state graphite support were developed and characterized in polyvinylchloride matrices. Precipitation-based technique with tetraphenylborate (TPB) as an electroactive material in polyvinylchloride (PVC) matrix was used for sensor 1 fabrication without incorporation of an ionophore. 2hydroxypropyl- β-cyclodextrin (HP-β-CD) based technique with tetraphenylborate and either dioctyl phatalate (DOP), dibutyl sebasate (DBS) or 2-nitrophenyl octyl ether (o- NPOE) as plastisizer in carboxylated polyvinylchloride (PVC-COOH) matrix were used for sensor 2, 3 and 4 fabrications, respectively. Fast and stable Nernstian responses were evaluated according to IUPAC recommendations in the concentration ranges from 1 × 10-5 to 1 × 10-3 M for sensor 1 , from 1 × 10-5 to 1 × 10-2 M for sensor 2, from 1 × 10-6 to 1 × 10-4 M for sensor 3, and from 1 × 10-6 to 1 × 10-3 M for sensor 4. The sensors show good selectivity to the drug in presence of a variety of inorganic and organic interferents including acid degradation product of torsemide, related substances and pharmaceutical excipients. Validation of the method showed the suitability of the proposed electrodes for the use in the quality control assessment of the drug. Furthermore, statistical comparison between the results obtained by the proposed method and the official method of the drug was performed and no significant difference was found. |
id |
RCAP_e3d532ac4f98dfda29dba0980e911f0b |
---|---|
oai_identifier_str |
oai:scielo:S0872-19042012000500004 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of TorsemideTorsemide-selective electrodegraphite electrode2-hydroxy propyl-βcyclodextrinstability indicating studypharmaceutical dosage formFour torsemide-selective electrodes all on solid state graphite support were developed and characterized in polyvinylchloride matrices. Precipitation-based technique with tetraphenylborate (TPB) as an electroactive material in polyvinylchloride (PVC) matrix was used for sensor 1 fabrication without incorporation of an ionophore. 2hydroxypropyl- β-cyclodextrin (HP-β-CD) based technique with tetraphenylborate and either dioctyl phatalate (DOP), dibutyl sebasate (DBS) or 2-nitrophenyl octyl ether (o- NPOE) as plastisizer in carboxylated polyvinylchloride (PVC-COOH) matrix were used for sensor 2, 3 and 4 fabrications, respectively. Fast and stable Nernstian responses were evaluated according to IUPAC recommendations in the concentration ranges from 1 × 10-5 to 1 × 10-3 M for sensor 1 , from 1 × 10-5 to 1 × 10-2 M for sensor 2, from 1 × 10-6 to 1 × 10-4 M for sensor 3, and from 1 × 10-6 to 1 × 10-3 M for sensor 4. The sensors show good selectivity to the drug in presence of a variety of inorganic and organic interferents including acid degradation product of torsemide, related substances and pharmaceutical excipients. Validation of the method showed the suitability of the proposed electrodes for the use in the quality control assessment of the drug. Furthermore, statistical comparison between the results obtained by the proposed method and the official method of the drug was performed and no significant difference was found.Sociedade Portuguesa de Electroquímica2012-09-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004Portugaliae Electrochimica Acta v.30 n.5 2012reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004Zaazaa,H.E.Abbas,S.S.Essam,Hebat A.M.El-Bardicy,M. G.info:eu-repo/semantics/openAccess2024-02-06T17:07:11Zoai:scielo:S0872-19042012000500004Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:20:12.999715Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
title |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
spellingShingle |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide Zaazaa,H.E. Torsemide-selective electrode graphite electrode 2-hydroxy propyl-βcyclodextrin stability indicating study pharmaceutical dosage form |
title_short |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
title_full |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
title_fullStr |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
title_full_unstemmed |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
title_sort |
Comparative Study of Different Plasticized Membrane Electrodes for the Stability-indicative Determination of Torsemide |
author |
Zaazaa,H.E. |
author_facet |
Zaazaa,H.E. Abbas,S.S. Essam,Hebat A.M. El-Bardicy,M. G. |
author_role |
author |
author2 |
Abbas,S.S. Essam,Hebat A.M. El-Bardicy,M. G. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Zaazaa,H.E. Abbas,S.S. Essam,Hebat A.M. El-Bardicy,M. G. |
dc.subject.por.fl_str_mv |
Torsemide-selective electrode graphite electrode 2-hydroxy propyl-βcyclodextrin stability indicating study pharmaceutical dosage form |
topic |
Torsemide-selective electrode graphite electrode 2-hydroxy propyl-βcyclodextrin stability indicating study pharmaceutical dosage form |
description |
Four torsemide-selective electrodes all on solid state graphite support were developed and characterized in polyvinylchloride matrices. Precipitation-based technique with tetraphenylborate (TPB) as an electroactive material in polyvinylchloride (PVC) matrix was used for sensor 1 fabrication without incorporation of an ionophore. 2hydroxypropyl- β-cyclodextrin (HP-β-CD) based technique with tetraphenylborate and either dioctyl phatalate (DOP), dibutyl sebasate (DBS) or 2-nitrophenyl octyl ether (o- NPOE) as plastisizer in carboxylated polyvinylchloride (PVC-COOH) matrix were used for sensor 2, 3 and 4 fabrications, respectively. Fast and stable Nernstian responses were evaluated according to IUPAC recommendations in the concentration ranges from 1 × 10-5 to 1 × 10-3 M for sensor 1 , from 1 × 10-5 to 1 × 10-2 M for sensor 2, from 1 × 10-6 to 1 × 10-4 M for sensor 3, and from 1 × 10-6 to 1 × 10-3 M for sensor 4. The sensors show good selectivity to the drug in presence of a variety of inorganic and organic interferents including acid degradation product of torsemide, related substances and pharmaceutical excipients. Validation of the method showed the suitability of the proposed electrodes for the use in the quality control assessment of the drug. Furthermore, statistical comparison between the results obtained by the proposed method and the official method of the drug was performed and no significant difference was found. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-09-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000500004 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
dc.source.none.fl_str_mv |
Portugaliae Electrochimica Acta v.30 n.5 2012 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799137290934550528 |