Fatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutments

Detalhes bibliográficos
Autor(a) principal: Ferreira, José Rocha
Data de Publicação: 2018
Outros Autores: Song, Nannan, Machado, Margarida, Machado, Luís Meira, Correia, André, Reis, Ana
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/72721
Resumo: This is an in vitro study composed by a fatigue test followed by an optical microscopy analysis. Dynamic abutments concept, recently introduced on screw-retained implant dental prosthesis, consists on the screw channel customisation according to the individual needs of each rehabilitation. Geometry and tightening torque differences advise the assessment of their mechanical performance. Clarify whether the combination of dynamic and conventional abutments in a three-unit implant-fixed prosthesis has detrimental effects either on the mechanical performance under cyclic loading or on the implant-abutment microgap dimensions. The fatigue test was performed in agreement with the ISO standard 14801. Then on the samples that resisted 5 million cycles, the implant-abutment microgap was measured on dynamic and conventional abutments using optical microscopy. Two unloaded samples were used as control group. The samples supported a load of 1050 N. The implant-abutment microgap measurement did not show statistically significant differences (p=.086) between loaded and unloaded groups, but the loaded conventional abutments showed a significant lower implant-abutment microgap (p=.05) than the loaded dynamic abutments. The combination of conventional and dynamic abutments do not seem to produce a decrease in fatigue resistance to a level below the mastication forces or an increase in the joint dimensions.
id RCAP_f214d2ba96e833c0494fbeec03c89f62
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/72721
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Fatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutmentsDynamic abutmentsFatigue testMicrogapCiências Médicas::Biotecnologia MédicaThis is an in vitro study composed by a fatigue test followed by an optical microscopy analysis. Dynamic abutments concept, recently introduced on screw-retained implant dental prosthesis, consists on the screw channel customisation according to the individual needs of each rehabilitation. Geometry and tightening torque differences advise the assessment of their mechanical performance. Clarify whether the combination of dynamic and conventional abutments in a three-unit implant-fixed prosthesis has detrimental effects either on the mechanical performance under cyclic loading or on the implant-abutment microgap dimensions. The fatigue test was performed in agreement with the ISO standard 14801. Then on the samples that resisted 5 million cycles, the implant-abutment microgap was measured on dynamic and conventional abutments using optical microscopy. Two unloaded samples were used as control group. The samples supported a load of 1050 N. The implant-abutment microgap measurement did not show statistically significant differences (p=.086) between loaded and unloaded groups, but the loaded conventional abutments showed a significant lower implant-abutment microgap (p=.05) than the loaded dynamic abutments. The combination of conventional and dynamic abutments do not seem to produce a decrease in fatigue resistance to a level below the mastication forces or an increase in the joint dimensions.The study was supported in part by SciTech - Science and Technology for Competitive and Sustainable Industries, and the R&D project was cofinanced by the North Portugal Regional Operational Program ("NORTE2020") and the European Regional Development Fund (FEDER).Informa HealthcareUniversidade do MinhoFerreira, José RochaSong, NannanMachado, MargaridaMachado, Luís MeiraCorreia, AndréReis, Ana20182018-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/72721engJosé Rocha Ferreira, Nannan Song, Margarida Machado, Luís Machado, André Correia & Ana Reis (2018) Fatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutments, Journal of Medical Engineering & Technology, 42:5, 397-405, DOI: 10.1080/03091902.2018.15203120309-19021464-522X10.1080/03091902.2018.152031230422735https://www.tandfonline.com/doi/full/10.1080/03091902.2018.1520312info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:05:42Zoai:repositorium.sdum.uminho.pt:1822/72721Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:56:12.317234Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Fatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutments
title Fatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutments
spellingShingle Fatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutments
Ferreira, José Rocha
Dynamic abutments
Fatigue test
Microgap
Ciências Médicas::Biotecnologia Médica
title_short Fatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutments
title_full Fatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutments
title_fullStr Fatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutments
title_full_unstemmed Fatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutments
title_sort Fatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutments
author Ferreira, José Rocha
author_facet Ferreira, José Rocha
Song, Nannan
Machado, Margarida
Machado, Luís Meira
Correia, André
Reis, Ana
author_role author
author2 Song, Nannan
Machado, Margarida
Machado, Luís Meira
Correia, André
Reis, Ana
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Ferreira, José Rocha
Song, Nannan
Machado, Margarida
Machado, Luís Meira
Correia, André
Reis, Ana
dc.subject.por.fl_str_mv Dynamic abutments
Fatigue test
Microgap
Ciências Médicas::Biotecnologia Médica
topic Dynamic abutments
Fatigue test
Microgap
Ciências Médicas::Biotecnologia Médica
description This is an in vitro study composed by a fatigue test followed by an optical microscopy analysis. Dynamic abutments concept, recently introduced on screw-retained implant dental prosthesis, consists on the screw channel customisation according to the individual needs of each rehabilitation. Geometry and tightening torque differences advise the assessment of their mechanical performance. Clarify whether the combination of dynamic and conventional abutments in a three-unit implant-fixed prosthesis has detrimental effects either on the mechanical performance under cyclic loading or on the implant-abutment microgap dimensions. The fatigue test was performed in agreement with the ISO standard 14801. Then on the samples that resisted 5 million cycles, the implant-abutment microgap was measured on dynamic and conventional abutments using optical microscopy. Two unloaded samples were used as control group. The samples supported a load of 1050 N. The implant-abutment microgap measurement did not show statistically significant differences (p=.086) between loaded and unloaded groups, but the loaded conventional abutments showed a significant lower implant-abutment microgap (p=.05) than the loaded dynamic abutments. The combination of conventional and dynamic abutments do not seem to produce a decrease in fatigue resistance to a level below the mastication forces or an increase in the joint dimensions.
publishDate 2018
dc.date.none.fl_str_mv 2018
2018-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/72721
url http://hdl.handle.net/1822/72721
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv José Rocha Ferreira, Nannan Song, Margarida Machado, Luís Machado, André Correia & Ana Reis (2018) Fatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutments, Journal of Medical Engineering & Technology, 42:5, 397-405, DOI: 10.1080/03091902.2018.1520312
0309-1902
1464-522X
10.1080/03091902.2018.1520312
30422735
https://www.tandfonline.com/doi/full/10.1080/03091902.2018.1520312
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Informa Healthcare
publisher.none.fl_str_mv Informa Healthcare
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132349341892608