Effect of cast rectifiers on the marginal fit of UCLA abutments

Detalhes bibliográficos
Autor(a) principal: Jaime,Ana Paula Gumieiro
Data de Publicação: 2007
Outros Autores: Vasconcellos,Diego Klee de, Mesquita,Alfredo Mikail Melo, Kimpara,Estevão Tomomitsu, Bottino,Marco Antonio
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572007000300004
Resumo: OBJECTIVES: This study assessed the effect of cast rectifiers on the marginal misfit of cast UCLA abutments compared to premachined UCLA abutments. The influence of casting and porcelain baking on the marginal misfit of these components was also investigated. METHODS: Two groups were analyzed: test group - 10 cast UCLA abutments, finished with cast rectifier and submitted to ceramic application; control group - 10 premachined UCLA abutments, cast with noble metal alloy and submitted to ceramic application. Vertical misfit measurements were performed under light microscopy. In the test group, measurements were performed before and after the use of cast rectifiers, and after ceramic application. In the control group, measurements were performed before and after casting, and after ceramic application. Data were submitted to statistical analysis by ANOVA and Tukey's test (a= 5%). RESULTS: The use of cast rectifiers significantly reduced the marginal misfit of cast UCLA abutments (from 25.68mm to 14.83mm; p<0.05). After ceramic application, the rectified cylinders presented misfit values (16.18mm) similar to those of premachined components (14.3 mm). Casting of the premachined UCLA abutments altered the marginal misfit of these components (from 9.63 mm to 14.6 mm; p<0.05). There were no significant changes after porcelain baking, in both groups. CONCLUSION: The use of cast rectifiers reduced the vertical misfit of cast UCLA abutments. Even with carefully performed laboratory steps, changes at the implant interface of premachined UCLA abutments occurred. Ceramic application did not alter the marginal misfit values of UCLA abutments.
id USP-17_aeac536f16f5bf311eec25366c5d386b
oai_identifier_str oai:scielo:S1678-77572007000300004
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Effect of cast rectifiers on the marginal fit of UCLA abutmentsDental abutmentsMisfitOBJECTIVES: This study assessed the effect of cast rectifiers on the marginal misfit of cast UCLA abutments compared to premachined UCLA abutments. The influence of casting and porcelain baking on the marginal misfit of these components was also investigated. METHODS: Two groups were analyzed: test group - 10 cast UCLA abutments, finished with cast rectifier and submitted to ceramic application; control group - 10 premachined UCLA abutments, cast with noble metal alloy and submitted to ceramic application. Vertical misfit measurements were performed under light microscopy. In the test group, measurements were performed before and after the use of cast rectifiers, and after ceramic application. In the control group, measurements were performed before and after casting, and after ceramic application. Data were submitted to statistical analysis by ANOVA and Tukey's test (a= 5%). RESULTS: The use of cast rectifiers significantly reduced the marginal misfit of cast UCLA abutments (from 25.68mm to 14.83mm; p<0.05). After ceramic application, the rectified cylinders presented misfit values (16.18mm) similar to those of premachined components (14.3 mm). Casting of the premachined UCLA abutments altered the marginal misfit of these components (from 9.63 mm to 14.6 mm; p<0.05). There were no significant changes after porcelain baking, in both groups. CONCLUSION: The use of cast rectifiers reduced the vertical misfit of cast UCLA abutments. Even with carefully performed laboratory steps, changes at the implant interface of premachined UCLA abutments occurred. Ceramic application did not alter the marginal misfit values of UCLA abutments.Faculdade De Odontologia De Bauru - USP2007-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572007000300004Journal of Applied Oral Science v.15 n.3 2007reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/S1678-77572007000300004info:eu-repo/semantics/openAccessJaime,Ana Paula GumieiroVasconcellos,Diego Klee deMesquita,Alfredo Mikail MeloKimpara,Estevão TomomitsuBottino,Marco Antonioeng2007-08-24T00:00:00Zoai:scielo:S1678-77572007000300004Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2007-08-24T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Effect of cast rectifiers on the marginal fit of UCLA abutments
title Effect of cast rectifiers on the marginal fit of UCLA abutments
spellingShingle Effect of cast rectifiers on the marginal fit of UCLA abutments
Jaime,Ana Paula Gumieiro
Dental abutments
Misfit
title_short Effect of cast rectifiers on the marginal fit of UCLA abutments
title_full Effect of cast rectifiers on the marginal fit of UCLA abutments
title_fullStr Effect of cast rectifiers on the marginal fit of UCLA abutments
title_full_unstemmed Effect of cast rectifiers on the marginal fit of UCLA abutments
title_sort Effect of cast rectifiers on the marginal fit of UCLA abutments
author Jaime,Ana Paula Gumieiro
author_facet Jaime,Ana Paula Gumieiro
Vasconcellos,Diego Klee de
Mesquita,Alfredo Mikail Melo
Kimpara,Estevão Tomomitsu
Bottino,Marco Antonio
author_role author
author2 Vasconcellos,Diego Klee de
Mesquita,Alfredo Mikail Melo
Kimpara,Estevão Tomomitsu
Bottino,Marco Antonio
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Jaime,Ana Paula Gumieiro
Vasconcellos,Diego Klee de
Mesquita,Alfredo Mikail Melo
Kimpara,Estevão Tomomitsu
Bottino,Marco Antonio
dc.subject.por.fl_str_mv Dental abutments
Misfit
topic Dental abutments
Misfit
description OBJECTIVES: This study assessed the effect of cast rectifiers on the marginal misfit of cast UCLA abutments compared to premachined UCLA abutments. The influence of casting and porcelain baking on the marginal misfit of these components was also investigated. METHODS: Two groups were analyzed: test group - 10 cast UCLA abutments, finished with cast rectifier and submitted to ceramic application; control group - 10 premachined UCLA abutments, cast with noble metal alloy and submitted to ceramic application. Vertical misfit measurements were performed under light microscopy. In the test group, measurements were performed before and after the use of cast rectifiers, and after ceramic application. In the control group, measurements were performed before and after casting, and after ceramic application. Data were submitted to statistical analysis by ANOVA and Tukey's test (a= 5%). RESULTS: The use of cast rectifiers significantly reduced the marginal misfit of cast UCLA abutments (from 25.68mm to 14.83mm; p<0.05). After ceramic application, the rectified cylinders presented misfit values (16.18mm) similar to those of premachined components (14.3 mm). Casting of the premachined UCLA abutments altered the marginal misfit of these components (from 9.63 mm to 14.6 mm; p<0.05). There were no significant changes after porcelain baking, in both groups. CONCLUSION: The use of cast rectifiers reduced the vertical misfit of cast UCLA abutments. Even with carefully performed laboratory steps, changes at the implant interface of premachined UCLA abutments occurred. Ceramic application did not alter the marginal misfit values of UCLA abutments.
publishDate 2007
dc.date.none.fl_str_mv 2007-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572007000300004
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572007000300004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1678-77572007000300004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
dc.source.none.fl_str_mv Journal of Applied Oral Science v.15 n.3 2007
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1748936434708905984