Monitoring the thermal efficiency of fouled heat exchangers: A simplified method

Detalhes bibliográficos
Autor(a) principal: Jerónimo, M. A. S.
Data de Publicação: 1997
Outros Autores: Melo, L. F., Braga, A. Sousa, Ferreira, P. J. B. F., Martins, C.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/16758
Resumo: Fouling is a problem whether we are aware of it or not. In an industrial plant, it is important not only to be able to measure the buildup of unwanted deposits, but also to do it in the simplest and most economically possible way. This paper addresses the question of monitoring fouling in an oil refinery plant, where the high number of heat exchanger units and the variability of the feedstock charge pose additional problems in terms of the practicability of following the energetic performance of such equipment. In this case, the flow rates and quality of the fluids flowing through the heat exchangers do not usually correspond to the design conditions, because they change with time. Therefore, to assess the fouling level of the exchangers, the day-to-day measured thermal efficiency should not be compared with the efficiency predicted in the design calculations. The latter should be recalculated by introducing whenever necessary new values of flow rates, physical properties, and so forth, and by evaluating new heat transfer coefficients. However, the procedures are too time consuming to be applied frequently. The present work describes a simplified method for following heat exchanger performances, based on the assessment of the number of transfer units and thermal efficiencies, where the effects of changing the feedstock charge, particularly the flow rates of the fluids, are taken into account. The only data that need to be collected are the four inlet/outlet temperatures of the heat exchanger unit and one of the flow rates. Several heat exchanger units in an oil refinery were successfully monitored by means of this method, and it was found that the variations in the physical properties did not significantly affect the results obtained for the particular plant under study.
id RCAP_f43c4812fcda19eb7c6fe8d6f9af58d9
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/16758
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Monitoring the thermal efficiency of fouled heat exchangers: A simplified methodfoulingmonitoringheat exchangersScience & TechnologyFouling is a problem whether we are aware of it or not. In an industrial plant, it is important not only to be able to measure the buildup of unwanted deposits, but also to do it in the simplest and most economically possible way. This paper addresses the question of monitoring fouling in an oil refinery plant, where the high number of heat exchanger units and the variability of the feedstock charge pose additional problems in terms of the practicability of following the energetic performance of such equipment. In this case, the flow rates and quality of the fluids flowing through the heat exchangers do not usually correspond to the design conditions, because they change with time. Therefore, to assess the fouling level of the exchangers, the day-to-day measured thermal efficiency should not be compared with the efficiency predicted in the design calculations. The latter should be recalculated by introducing whenever necessary new values of flow rates, physical properties, and so forth, and by evaluating new heat transfer coefficients. However, the procedures are too time consuming to be applied frequently. The present work describes a simplified method for following heat exchanger performances, based on the assessment of the number of transfer units and thermal efficiencies, where the effects of changing the feedstock charge, particularly the flow rates of the fluids, are taken into account. The only data that need to be collected are the four inlet/outlet temperatures of the heat exchanger unit and one of the flow rates. Several heat exchanger units in an oil refinery were successfully monitored by means of this method, and it was found that the variations in the physical properties did not significantly affect the results obtained for the particular plant under study.ElsevierUniversidade do MinhoJerónimo, M. A. S.Melo, L. F.Braga, A. SousaFerreira, P. J. B. F.Martins, C.1997-051997-05-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/16758eng0894-177710.1016/S0894-1777(96)00146-Xinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:41:54Zoai:repositorium.sdum.uminho.pt:1822/16758Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:39:00.481339Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Monitoring the thermal efficiency of fouled heat exchangers: A simplified method
title Monitoring the thermal efficiency of fouled heat exchangers: A simplified method
spellingShingle Monitoring the thermal efficiency of fouled heat exchangers: A simplified method
Jerónimo, M. A. S.
fouling
monitoring
heat exchangers
Science & Technology
title_short Monitoring the thermal efficiency of fouled heat exchangers: A simplified method
title_full Monitoring the thermal efficiency of fouled heat exchangers: A simplified method
title_fullStr Monitoring the thermal efficiency of fouled heat exchangers: A simplified method
title_full_unstemmed Monitoring the thermal efficiency of fouled heat exchangers: A simplified method
title_sort Monitoring the thermal efficiency of fouled heat exchangers: A simplified method
author Jerónimo, M. A. S.
author_facet Jerónimo, M. A. S.
Melo, L. F.
Braga, A. Sousa
Ferreira, P. J. B. F.
Martins, C.
author_role author
author2 Melo, L. F.
Braga, A. Sousa
Ferreira, P. J. B. F.
Martins, C.
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Jerónimo, M. A. S.
Melo, L. F.
Braga, A. Sousa
Ferreira, P. J. B. F.
Martins, C.
dc.subject.por.fl_str_mv fouling
monitoring
heat exchangers
Science & Technology
topic fouling
monitoring
heat exchangers
Science & Technology
description Fouling is a problem whether we are aware of it or not. In an industrial plant, it is important not only to be able to measure the buildup of unwanted deposits, but also to do it in the simplest and most economically possible way. This paper addresses the question of monitoring fouling in an oil refinery plant, where the high number of heat exchanger units and the variability of the feedstock charge pose additional problems in terms of the practicability of following the energetic performance of such equipment. In this case, the flow rates and quality of the fluids flowing through the heat exchangers do not usually correspond to the design conditions, because they change with time. Therefore, to assess the fouling level of the exchangers, the day-to-day measured thermal efficiency should not be compared with the efficiency predicted in the design calculations. The latter should be recalculated by introducing whenever necessary new values of flow rates, physical properties, and so forth, and by evaluating new heat transfer coefficients. However, the procedures are too time consuming to be applied frequently. The present work describes a simplified method for following heat exchanger performances, based on the assessment of the number of transfer units and thermal efficiencies, where the effects of changing the feedstock charge, particularly the flow rates of the fluids, are taken into account. The only data that need to be collected are the four inlet/outlet temperatures of the heat exchanger unit and one of the flow rates. Several heat exchanger units in an oil refinery were successfully monitored by means of this method, and it was found that the variations in the physical properties did not significantly affect the results obtained for the particular plant under study.
publishDate 1997
dc.date.none.fl_str_mv 1997-05
1997-05-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/16758
url http://hdl.handle.net/1822/16758
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0894-1777
10.1016/S0894-1777(96)00146-X
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132929931083776