Monitoring the thermal efficiency of fouled heat exchangers: A simplified method
Autor(a) principal: | |
---|---|
Data de Publicação: | 1997 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/16758 |
Resumo: | Fouling is a problem whether we are aware of it or not. In an industrial plant, it is important not only to be able to measure the buildup of unwanted deposits, but also to do it in the simplest and most economically possible way. This paper addresses the question of monitoring fouling in an oil refinery plant, where the high number of heat exchanger units and the variability of the feedstock charge pose additional problems in terms of the practicability of following the energetic performance of such equipment. In this case, the flow rates and quality of the fluids flowing through the heat exchangers do not usually correspond to the design conditions, because they change with time. Therefore, to assess the fouling level of the exchangers, the day-to-day measured thermal efficiency should not be compared with the efficiency predicted in the design calculations. The latter should be recalculated by introducing whenever necessary new values of flow rates, physical properties, and so forth, and by evaluating new heat transfer coefficients. However, the procedures are too time consuming to be applied frequently. The present work describes a simplified method for following heat exchanger performances, based on the assessment of the number of transfer units and thermal efficiencies, where the effects of changing the feedstock charge, particularly the flow rates of the fluids, are taken into account. The only data that need to be collected are the four inlet/outlet temperatures of the heat exchanger unit and one of the flow rates. Several heat exchanger units in an oil refinery were successfully monitored by means of this method, and it was found that the variations in the physical properties did not significantly affect the results obtained for the particular plant under study. |
id |
RCAP_f43c4812fcda19eb7c6fe8d6f9af58d9 |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/16758 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Monitoring the thermal efficiency of fouled heat exchangers: A simplified methodfoulingmonitoringheat exchangersScience & TechnologyFouling is a problem whether we are aware of it or not. In an industrial plant, it is important not only to be able to measure the buildup of unwanted deposits, but also to do it in the simplest and most economically possible way. This paper addresses the question of monitoring fouling in an oil refinery plant, where the high number of heat exchanger units and the variability of the feedstock charge pose additional problems in terms of the practicability of following the energetic performance of such equipment. In this case, the flow rates and quality of the fluids flowing through the heat exchangers do not usually correspond to the design conditions, because they change with time. Therefore, to assess the fouling level of the exchangers, the day-to-day measured thermal efficiency should not be compared with the efficiency predicted in the design calculations. The latter should be recalculated by introducing whenever necessary new values of flow rates, physical properties, and so forth, and by evaluating new heat transfer coefficients. However, the procedures are too time consuming to be applied frequently. The present work describes a simplified method for following heat exchanger performances, based on the assessment of the number of transfer units and thermal efficiencies, where the effects of changing the feedstock charge, particularly the flow rates of the fluids, are taken into account. The only data that need to be collected are the four inlet/outlet temperatures of the heat exchanger unit and one of the flow rates. Several heat exchanger units in an oil refinery were successfully monitored by means of this method, and it was found that the variations in the physical properties did not significantly affect the results obtained for the particular plant under study.ElsevierUniversidade do MinhoJerónimo, M. A. S.Melo, L. F.Braga, A. SousaFerreira, P. J. B. F.Martins, C.1997-051997-05-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/16758eng0894-177710.1016/S0894-1777(96)00146-Xinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:41:54Zoai:repositorium.sdum.uminho.pt:1822/16758Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:39:00.481339Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Monitoring the thermal efficiency of fouled heat exchangers: A simplified method |
title |
Monitoring the thermal efficiency of fouled heat exchangers: A simplified method |
spellingShingle |
Monitoring the thermal efficiency of fouled heat exchangers: A simplified method Jerónimo, M. A. S. fouling monitoring heat exchangers Science & Technology |
title_short |
Monitoring the thermal efficiency of fouled heat exchangers: A simplified method |
title_full |
Monitoring the thermal efficiency of fouled heat exchangers: A simplified method |
title_fullStr |
Monitoring the thermal efficiency of fouled heat exchangers: A simplified method |
title_full_unstemmed |
Monitoring the thermal efficiency of fouled heat exchangers: A simplified method |
title_sort |
Monitoring the thermal efficiency of fouled heat exchangers: A simplified method |
author |
Jerónimo, M. A. S. |
author_facet |
Jerónimo, M. A. S. Melo, L. F. Braga, A. Sousa Ferreira, P. J. B. F. Martins, C. |
author_role |
author |
author2 |
Melo, L. F. Braga, A. Sousa Ferreira, P. J. B. F. Martins, C. |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Jerónimo, M. A. S. Melo, L. F. Braga, A. Sousa Ferreira, P. J. B. F. Martins, C. |
dc.subject.por.fl_str_mv |
fouling monitoring heat exchangers Science & Technology |
topic |
fouling monitoring heat exchangers Science & Technology |
description |
Fouling is a problem whether we are aware of it or not. In an industrial plant, it is important not only to be able to measure the buildup of unwanted deposits, but also to do it in the simplest and most economically possible way. This paper addresses the question of monitoring fouling in an oil refinery plant, where the high number of heat exchanger units and the variability of the feedstock charge pose additional problems in terms of the practicability of following the energetic performance of such equipment. In this case, the flow rates and quality of the fluids flowing through the heat exchangers do not usually correspond to the design conditions, because they change with time. Therefore, to assess the fouling level of the exchangers, the day-to-day measured thermal efficiency should not be compared with the efficiency predicted in the design calculations. The latter should be recalculated by introducing whenever necessary new values of flow rates, physical properties, and so forth, and by evaluating new heat transfer coefficients. However, the procedures are too time consuming to be applied frequently. The present work describes a simplified method for following heat exchanger performances, based on the assessment of the number of transfer units and thermal efficiencies, where the effects of changing the feedstock charge, particularly the flow rates of the fluids, are taken into account. The only data that need to be collected are the four inlet/outlet temperatures of the heat exchanger unit and one of the flow rates. Several heat exchanger units in an oil refinery were successfully monitored by means of this method, and it was found that the variations in the physical properties did not significantly affect the results obtained for the particular plant under study. |
publishDate |
1997 |
dc.date.none.fl_str_mv |
1997-05 1997-05-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/16758 |
url |
http://hdl.handle.net/1822/16758 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
0894-1777 10.1016/S0894-1777(96)00146-X |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799132929931083776 |