Determination of cobalt in wine and must by electrothermalatomization atomic absorption spectrometry: analyticalmethod development and validation
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S0254-02232009000200002 |
Resumo: | An electrothermal atomization atomic absorption spectrometry method was optimized to quantify cobalt in musts and wines, especially within quality control scope. As far as wine samples are concerned, the method involves reduced risk of contamination by eliminating prior treatment other than dilution (1:2). For must samples a pre-treatment is needed, in order to destroy the organic matter that could interfere with the analytical determination. A conventional thermal program (with pyrolysis step), with and without matrix modifier [Mg(NO3)2], was developed and optimized. Pyrolysis and atomization curves were studied using a Co standard solution, must and wine samples. The analytical figures of merit of the method such as linearity of the calibration curve, specificity (standard additions test), accuracy, analytical limits and precision were studied using wine samples. The linear dynamic range under optimized conditions was 0.4-10.0 μg/L. The recoveries were between 87% and 98% for all of the wines and addition levels used in the test. The method presents a very satisfactory specificity for red wines, while matrix effect was observed for white wines. The limit of detection in undiluted wines was 0.8 μg/L. Repeatability was lower than 0.7 μg/L (RSD < 5%). For accuracy evaluation, Co content in six wine samples and one Co standard solution, from an international collaborative trial, was determined by ETAAS and ICP-MS with comparable results (in general the differences were lower than 5%). Bearing in mind that must samples are previously digested, it is expected that the method performance parameters are at least as favourable as those observed with wines. |
id |
RCAP_f69ef1fa653b5a607a6c9b254937c2b9 |
---|---|
oai_identifier_str |
oai:scielo:S0254-02232009000200002 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Determination of cobalt in wine and must by electrothermalatomization atomic absorption spectrometry: analyticalmethod development and validationwinecobaltanalytical method validationelectrothermal atomization atomic absorption spectrometryAn electrothermal atomization atomic absorption spectrometry method was optimized to quantify cobalt in musts and wines, especially within quality control scope. As far as wine samples are concerned, the method involves reduced risk of contamination by eliminating prior treatment other than dilution (1:2). For must samples a pre-treatment is needed, in order to destroy the organic matter that could interfere with the analytical determination. A conventional thermal program (with pyrolysis step), with and without matrix modifier [Mg(NO3)2], was developed and optimized. Pyrolysis and atomization curves were studied using a Co standard solution, must and wine samples. The analytical figures of merit of the method such as linearity of the calibration curve, specificity (standard additions test), accuracy, analytical limits and precision were studied using wine samples. The linear dynamic range under optimized conditions was 0.4-10.0 μg/L. The recoveries were between 87% and 98% for all of the wines and addition levels used in the test. The method presents a very satisfactory specificity for red wines, while matrix effect was observed for white wines. The limit of detection in undiluted wines was 0.8 μg/L. Repeatability was lower than 0.7 μg/L (RSD < 5%). For accuracy evaluation, Co content in six wine samples and one Co standard solution, from an international collaborative trial, was determined by ETAAS and ICP-MS with comparable results (in general the differences were lower than 5%). Bearing in mind that must samples are previously digested, it is expected that the method performance parameters are at least as favourable as those observed with wines.INIAV - DOIS PORTOS (Ex-Estação Vitivinícola Nacional)2009-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0254-02232009000200002Ciência e Técnica Vitivinícola v.24 n.2 2009reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0254-02232009000200002Catarino,S.Neves,A.Sousa,R. Bruno deinfo:eu-repo/semantics/openAccess2024-02-06T16:57:46Zoai:scielo:S0254-02232009000200002Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:14:48.850564Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Determination of cobalt in wine and must by electrothermalatomization atomic absorption spectrometry: analyticalmethod development and validation |
title |
Determination of cobalt in wine and must by electrothermalatomization atomic absorption spectrometry: analyticalmethod development and validation |
spellingShingle |
Determination of cobalt in wine and must by electrothermalatomization atomic absorption spectrometry: analyticalmethod development and validation Catarino,S. wine cobalt analytical method validation electrothermal atomization atomic absorption spectrometry |
title_short |
Determination of cobalt in wine and must by electrothermalatomization atomic absorption spectrometry: analyticalmethod development and validation |
title_full |
Determination of cobalt in wine and must by electrothermalatomization atomic absorption spectrometry: analyticalmethod development and validation |
title_fullStr |
Determination of cobalt in wine and must by electrothermalatomization atomic absorption spectrometry: analyticalmethod development and validation |
title_full_unstemmed |
Determination of cobalt in wine and must by electrothermalatomization atomic absorption spectrometry: analyticalmethod development and validation |
title_sort |
Determination of cobalt in wine and must by electrothermalatomization atomic absorption spectrometry: analyticalmethod development and validation |
author |
Catarino,S. |
author_facet |
Catarino,S. Neves,A. Sousa,R. Bruno de |
author_role |
author |
author2 |
Neves,A. Sousa,R. Bruno de |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Catarino,S. Neves,A. Sousa,R. Bruno de |
dc.subject.por.fl_str_mv |
wine cobalt analytical method validation electrothermal atomization atomic absorption spectrometry |
topic |
wine cobalt analytical method validation electrothermal atomization atomic absorption spectrometry |
description |
An electrothermal atomization atomic absorption spectrometry method was optimized to quantify cobalt in musts and wines, especially within quality control scope. As far as wine samples are concerned, the method involves reduced risk of contamination by eliminating prior treatment other than dilution (1:2). For must samples a pre-treatment is needed, in order to destroy the organic matter that could interfere with the analytical determination. A conventional thermal program (with pyrolysis step), with and without matrix modifier [Mg(NO3)2], was developed and optimized. Pyrolysis and atomization curves were studied using a Co standard solution, must and wine samples. The analytical figures of merit of the method such as linearity of the calibration curve, specificity (standard additions test), accuracy, analytical limits and precision were studied using wine samples. The linear dynamic range under optimized conditions was 0.4-10.0 μg/L. The recoveries were between 87% and 98% for all of the wines and addition levels used in the test. The method presents a very satisfactory specificity for red wines, while matrix effect was observed for white wines. The limit of detection in undiluted wines was 0.8 μg/L. Repeatability was lower than 0.7 μg/L (RSD < 5%). For accuracy evaluation, Co content in six wine samples and one Co standard solution, from an international collaborative trial, was determined by ETAAS and ICP-MS with comparable results (in general the differences were lower than 5%). Bearing in mind that must samples are previously digested, it is expected that the method performance parameters are at least as favourable as those observed with wines. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-01-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0254-02232009000200002 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0254-02232009000200002 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0254-02232009000200002 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
INIAV - DOIS PORTOS (Ex-Estação Vitivinícola Nacional) |
publisher.none.fl_str_mv |
INIAV - DOIS PORTOS (Ex-Estação Vitivinícola Nacional) |
dc.source.none.fl_str_mv |
Ciência e Técnica Vitivinícola v.24 n.2 2009 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799137248971587584 |