Colete inteligente para contenção e monitorização electrocardiográfica pós cirurgia cardíaca
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10451/11066 |
Resumo: | Tese de mestrado integrado em Engenharia Biomédica e Biofísica, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2014 |
id |
RCAP_fd67b5c9892cc3df00d3a8fcf6057ea6 |
---|---|
oai_identifier_str |
oai:repositorio.ul.pt:10451/11066 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Colete inteligente para contenção e monitorização electrocardiográfica pós cirurgia cardíacaColete de contençãoMonitorização electrocardiográficaCirurgia cardíacaSensoresSmartphonesTêxteis inteligentesTeses de mestrado - 2014Tese de mestrado integrado em Engenharia Biomédica e Biofísica, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2014No pós-operatório de uma cirurgia cardíaca, por esternotomia mediana, para além da dor percepcionada pelo doente, existe a possibilidade de ocorrer deiscência do esterno. Por outro lado as alterações de ritmo são uma das complicações mais frequentes na cirurgia cardíaca. Tanto a deiscência do esterno como as alterações de ritmo condicionam a um aumento da morbilidade e mortalidade dos doentes. O uso de um colete de contenção de esterno é recomendado de acordo com o tipo e complicações da cirurgia, bem como as comorbilidades do doente. E deve ser usado o mais precocemente possível, permitindo assim um maior conforto e uma reabilitação cardíaca mais rápida. A monitorização do ritmo cardíaco no pós-operatório é essencial para despiste de alterações electrocardiográficas, sendo obrigatória durante o internamento na unidade de cuidados intensivos, para todos os doentes, e na enfermaria em doentes com maior risco. O e-Lifevest surge da necessidade de associar um sistema de monitorização cardíaca a um colete de contenção do esterno. A criação do e-Lifevest resulta do desenvolvimento de sensores (eléctrodos têxteis), hardware e de interconexões eléctricas incorporados num colete de contenção de esterno, e da utilização do Lilypad-Arduino® como microcontrolador. Além disso a incorporação do Bluetooth, permite a troca de informação em tempo real à distância, através de um Tablet-BQ® dotado do sistema operativo Android®, onde o sinal electrofisiológico recebido é visualizado, armazenado e processado. Fez-se um estudo exploratório para demonstrar a fiabilidade, precisão e operabilidade do e-Lifevest. A amostra foi constituída por 9 indivíduos saudáveis, tendo sido comparados os dados registados num desfibrilhador da Medtronic®, Lifepak®, com os dados do e-Lifevest e avaliada a precisão dos intervalos R-R. Verificou-se que a taxa de amostragem programada do e-Lifevest (125Hz) encontra-se dentro do intervalo da taxa de amostragem experimental obtida [122-126Hz]. Desenvolveu-se um algoritmo capaz de detectar e visualizar as ondas R e ao mesmo tempo as respectivas falhas de detecção destas. Desta forma, a taxa de amostragem e a correcta detecção das ondas R permitiram obter uma boa aproximação do ritmo cardíaco real. Posteriormente os dados armazenados pelo aplicativo Android, foram analisados pelo Matlab®, sendo realizada uma análise exploratória estatística dos intervalos RR, permitindo estabelecer um intervalo com um erro de 10% para o intervalo RR normal. Assim, este resultado permitiu inferir sobre a ritmicidade do traçado. O e-Lifevest pretende ser um sistema de monitorização remota de baixo custo, fácil uso, de baixo consumo, capaz de detectar arritmias e ser lavável.At post-op cardiac surgery by median sternotomy, further than pain, there is a possibility of sternum events. On the other hand rhythm changes are one of the most frequent complications in cardiac surgery. Both the dehiscence and the changes in rhythm influence an increase in morbidity and mortality in patients who have undergone cardiac surgery. Therefore, the use of a restraint vest of the breastbone is recommended according to the kind and complications surgery as well as the patient's co-morbidities. It should be used as early as possible, thus allowing a greater comfort and a faster cardiac rehabilitation. The monitoring of the heart rhythm postoperatively is recommended for screening changes in electrocardiographic, being mandatory during hospitalization in the intensive care unit, for all patients, and in the ward only in patients with higher risk. The e-Lifevest arises from the need to associate a cardiac monitoring system to a vest of containment of the sternum. The design of e-Lifevest consisted in developing sensors (electrodes), and electrical interconnection hardware incorporated into a vest, as well as in the use of the Arduino Lilypad ® as microcontroller. Furthermore the incorporation of Bluetooth ® enables the exchange of real-time information from a distance, with a Tablet-BQ ® equipped with Android ® operating system, where the electrophysiological signal received was viewed, stored and processed. We made an exploratory study to demonstrate the reliability, accuracy and operability of the e-Lifevest on a sample of nine healthy individuals. We compared the data registered in a defibrillator from Lifepak ®, Medtronic ®, with to e-Lifevest´s data. We assessed precision of R-R intervals, through the Lifepak® and the e-Lifevest sampling rates. It was found that the scheduled sampling rate of the e-Lifevest (125 Hz) lies within the experimental range sampling rate obtained [122-126Hz]. Developed an algorithm able to detect and visualize the waves R and at the same time their detection failures. In this way, the sample rate and the correct detection of the waves R allowed to obtain a good approximation of the actual heart rate.Subsequently the data stored by the Android application was analyzed by Matlab ®, and an exploratory statistical analysis of RR intervals was carried out, allowing a range to be established with an error of 10% for the normal RR interval. This result allowed us to infer the rhythmicity of the stroke. The e-Lifevest aims to be a remote monitoring system of low cost, easy to use, low consumption, able to detect arrhythmias and is washable.Ferreira, Hugo AlexandreRepositório da Universidade de LisboaOliveira, José Gregório Gonçalves2014-05-30T15:20:56Z20142014-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10451/11066TID:201291657porinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-08T15:56:58Zoai:repositorio.ul.pt:10451/11066Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:34:51.649767Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Colete inteligente para contenção e monitorização electrocardiográfica pós cirurgia cardíaca |
title |
Colete inteligente para contenção e monitorização electrocardiográfica pós cirurgia cardíaca |
spellingShingle |
Colete inteligente para contenção e monitorização electrocardiográfica pós cirurgia cardíaca Oliveira, José Gregório Gonçalves Colete de contenção Monitorização electrocardiográfica Cirurgia cardíaca Sensores Smartphones Têxteis inteligentes Teses de mestrado - 2014 |
title_short |
Colete inteligente para contenção e monitorização electrocardiográfica pós cirurgia cardíaca |
title_full |
Colete inteligente para contenção e monitorização electrocardiográfica pós cirurgia cardíaca |
title_fullStr |
Colete inteligente para contenção e monitorização electrocardiográfica pós cirurgia cardíaca |
title_full_unstemmed |
Colete inteligente para contenção e monitorização electrocardiográfica pós cirurgia cardíaca |
title_sort |
Colete inteligente para contenção e monitorização electrocardiográfica pós cirurgia cardíaca |
author |
Oliveira, José Gregório Gonçalves |
author_facet |
Oliveira, José Gregório Gonçalves |
author_role |
author |
dc.contributor.none.fl_str_mv |
Ferreira, Hugo Alexandre Repositório da Universidade de Lisboa |
dc.contributor.author.fl_str_mv |
Oliveira, José Gregório Gonçalves |
dc.subject.por.fl_str_mv |
Colete de contenção Monitorização electrocardiográfica Cirurgia cardíaca Sensores Smartphones Têxteis inteligentes Teses de mestrado - 2014 |
topic |
Colete de contenção Monitorização electrocardiográfica Cirurgia cardíaca Sensores Smartphones Têxteis inteligentes Teses de mestrado - 2014 |
description |
Tese de mestrado integrado em Engenharia Biomédica e Biofísica, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2014 |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-05-30T15:20:56Z 2014 2014-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10451/11066 TID:201291657 |
url |
http://hdl.handle.net/10451/11066 |
identifier_str_mv |
TID:201291657 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799134244530814976 |