Correlation between oro and hypopharynx shape and position with endotracheal intubation difficulty

Detalhes bibliográficos
Autor(a) principal: Rabadi,Daher
Data de Publicação: 2014
Outros Autores: Baker,Ahmad Abu, Al-Qudah,Mohannad
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Anestesiologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942014000600433
Resumo: Background and objective: Prediction of intubation difficulty can save patients from major preoperative morbidity or mortality. The purpose of this paper is to assess the correlation between oro-hypo pharynx position, neck size, and length with endotracheal intubation difficulty. The study also explored the diagnostic value of Friedman Staging System in prediction cases with difficult intubation. Method: The consecutive 500 ASA (I, II) adult patients undergoing elective surgery were evaluated for oro and hypopharynx shape and position by modified Mallampati, Cormack and Lehane score as well as Friedman obstructive sleep apnea classification systems. Neck circumference and length were also measured. All cases were intubated by a single anesthesiologist who was uninformed of the above evaluation and graded intubation difficulty in visual analog score. Correlation between these findings and difficulty of intubation was assessed. Sensitivity, Specificity, Positive and Negative Predictive Values were also reported. Results: Cormack-Lehane grade had the strongest correlation with difficulty of intubation followed by Friedman palate position. Friedman palate position was the most sensitive and had higher positive and negative predictive values than modified Mallampati classification. Cormack-Lehane grade was found to be the most specific with the highest negative predictive value among the four studied classifications. Conclusion: Friedman palate position is a more useful, valuable and sensitive test compared to the modified Mallampati screening test for pre-anesthetic prediction of difficult intubation where its involvement in Multivariate model may raise the accuracy and diagnostic value of preoperative assessment of difficult airway.
id SBA-1_adfebabb9b280b2579d9a7e9f8f8a50b
oai_identifier_str oai:scielo:S0034-70942014000600433
network_acronym_str SBA-1
network_name_str Revista Brasileira de Anestesiologia (Online)
repository_id_str
spelling Correlation between oro and hypopharynx shape and position with endotracheal intubation difficultyIntubationAirwayPharynxClassificationCorrelationValue Background and objective: Prediction of intubation difficulty can save patients from major preoperative morbidity or mortality. The purpose of this paper is to assess the correlation between oro-hypo pharynx position, neck size, and length with endotracheal intubation difficulty. The study also explored the diagnostic value of Friedman Staging System in prediction cases with difficult intubation. Method: The consecutive 500 ASA (I, II) adult patients undergoing elective surgery were evaluated for oro and hypopharynx shape and position by modified Mallampati, Cormack and Lehane score as well as Friedman obstructive sleep apnea classification systems. Neck circumference and length were also measured. All cases were intubated by a single anesthesiologist who was uninformed of the above evaluation and graded intubation difficulty in visual analog score. Correlation between these findings and difficulty of intubation was assessed. Sensitivity, Specificity, Positive and Negative Predictive Values were also reported. Results: Cormack-Lehane grade had the strongest correlation with difficulty of intubation followed by Friedman palate position. Friedman palate position was the most sensitive and had higher positive and negative predictive values than modified Mallampati classification. Cormack-Lehane grade was found to be the most specific with the highest negative predictive value among the four studied classifications. Conclusion: Friedman palate position is a more useful, valuable and sensitive test compared to the modified Mallampati screening test for pre-anesthetic prediction of difficult intubation where its involvement in Multivariate model may raise the accuracy and diagnostic value of preoperative assessment of difficult airway. Sociedade Brasileira de Anestesiologia2014-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942014000600433Revista Brasileira de Anestesiologia v.64 n.6 2014reponame:Revista Brasileira de Anestesiologia (Online)instname:Sociedade Brasileira de Anestesiologia (SBA)instacron:SBA10.1016/j.bjane.2013.08.003info:eu-repo/semantics/openAccessRabadi,DaherBaker,Ahmad AbuAl-Qudah,Mohannadeng2015-08-25T00:00:00Zoai:scielo:S0034-70942014000600433Revistahttps://www.sbahq.org/revista/https://old.scielo.br/oai/scielo-oai.php||sba2000@openlink.com.br1806-907X0034-7094opendoar:2015-08-25T00:00Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)false
dc.title.none.fl_str_mv Correlation between oro and hypopharynx shape and position with endotracheal intubation difficulty
title Correlation between oro and hypopharynx shape and position with endotracheal intubation difficulty
spellingShingle Correlation between oro and hypopharynx shape and position with endotracheal intubation difficulty
Rabadi,Daher
Intubation
Airway
Pharynx
Classification
Correlation
Value
title_short Correlation between oro and hypopharynx shape and position with endotracheal intubation difficulty
title_full Correlation between oro and hypopharynx shape and position with endotracheal intubation difficulty
title_fullStr Correlation between oro and hypopharynx shape and position with endotracheal intubation difficulty
title_full_unstemmed Correlation between oro and hypopharynx shape and position with endotracheal intubation difficulty
title_sort Correlation between oro and hypopharynx shape and position with endotracheal intubation difficulty
author Rabadi,Daher
author_facet Rabadi,Daher
Baker,Ahmad Abu
Al-Qudah,Mohannad
author_role author
author2 Baker,Ahmad Abu
Al-Qudah,Mohannad
author2_role author
author
dc.contributor.author.fl_str_mv Rabadi,Daher
Baker,Ahmad Abu
Al-Qudah,Mohannad
dc.subject.por.fl_str_mv Intubation
Airway
Pharynx
Classification
Correlation
Value
topic Intubation
Airway
Pharynx
Classification
Correlation
Value
description Background and objective: Prediction of intubation difficulty can save patients from major preoperative morbidity or mortality. The purpose of this paper is to assess the correlation between oro-hypo pharynx position, neck size, and length with endotracheal intubation difficulty. The study also explored the diagnostic value of Friedman Staging System in prediction cases with difficult intubation. Method: The consecutive 500 ASA (I, II) adult patients undergoing elective surgery were evaluated for oro and hypopharynx shape and position by modified Mallampati, Cormack and Lehane score as well as Friedman obstructive sleep apnea classification systems. Neck circumference and length were also measured. All cases were intubated by a single anesthesiologist who was uninformed of the above evaluation and graded intubation difficulty in visual analog score. Correlation between these findings and difficulty of intubation was assessed. Sensitivity, Specificity, Positive and Negative Predictive Values were also reported. Results: Cormack-Lehane grade had the strongest correlation with difficulty of intubation followed by Friedman palate position. Friedman palate position was the most sensitive and had higher positive and negative predictive values than modified Mallampati classification. Cormack-Lehane grade was found to be the most specific with the highest negative predictive value among the four studied classifications. Conclusion: Friedman palate position is a more useful, valuable and sensitive test compared to the modified Mallampati screening test for pre-anesthetic prediction of difficult intubation where its involvement in Multivariate model may raise the accuracy and diagnostic value of preoperative assessment of difficult airway.
publishDate 2014
dc.date.none.fl_str_mv 2014-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942014000600433
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942014000600433
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.bjane.2013.08.003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Anestesiologia
publisher.none.fl_str_mv Sociedade Brasileira de Anestesiologia
dc.source.none.fl_str_mv Revista Brasileira de Anestesiologia v.64 n.6 2014
reponame:Revista Brasileira de Anestesiologia (Online)
instname:Sociedade Brasileira de Anestesiologia (SBA)
instacron:SBA
instname_str Sociedade Brasileira de Anestesiologia (SBA)
instacron_str SBA
institution SBA
reponame_str Revista Brasileira de Anestesiologia (Online)
collection Revista Brasileira de Anestesiologia (Online)
repository.name.fl_str_mv Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)
repository.mail.fl_str_mv ||sba2000@openlink.com.br
_version_ 1752126628209623040