Oxytocin in cesarean-sections. What's new?
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Anestesiologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942016000400402 |
Resumo: | Abstract Oxytocin is the uterotonic agent of choice in the prevention and treatment of postpartum uterine atony. Nevertheless, there is no consensus on the optimal dose and rate for use in cesarean sections. The use of high bolus doses (e.g., 10 IU of oxytocin) can determine deleterious cardiovascular changes for the patient, especially in situations of hypovolemia or low cardiac reserve. Furthermore, high doses of oxytocin for prolonged periods may lead to desensitization of oxytocin receptors in myometrium, resulting in clinical inefficiency. |
id |
SBA-1_af95256abaaa336b1f935ae683b48df5 |
---|---|
oai_identifier_str |
oai:scielo:S0034-70942016000400402 |
network_acronym_str |
SBA-1 |
network_name_str |
Revista Brasileira de Anestesiologia (Online) |
repository_id_str |
|
spelling |
Oxytocin in cesarean-sections. What's new?OxytocinCesarean sectionDesensitizationDoseAbstract Oxytocin is the uterotonic agent of choice in the prevention and treatment of postpartum uterine atony. Nevertheless, there is no consensus on the optimal dose and rate for use in cesarean sections. The use of high bolus doses (e.g., 10 IU of oxytocin) can determine deleterious cardiovascular changes for the patient, especially in situations of hypovolemia or low cardiac reserve. Furthermore, high doses of oxytocin for prolonged periods may lead to desensitization of oxytocin receptors in myometrium, resulting in clinical inefficiency.Sociedade Brasileira de Anestesiologia2016-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942016000400402Revista Brasileira de Anestesiologia v.66 n.4 2016reponame:Revista Brasileira de Anestesiologia (Online)instname:Sociedade Brasileira de Anestesiologia (SBA)instacron:SBA10.1016/j.bjane.2014.11.015info:eu-repo/semantics/openAccessYamaguchi,Eduardo TsuyoshiSiaulys,Mônica MariaTorres,Marcelo Luis Abramideseng2016-07-21T00:00:00Zoai:scielo:S0034-70942016000400402Revistahttps://www.sbahq.org/revista/https://old.scielo.br/oai/scielo-oai.php||sba2000@openlink.com.br1806-907X0034-7094opendoar:2016-07-21T00:00Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)false |
dc.title.none.fl_str_mv |
Oxytocin in cesarean-sections. What's new? |
title |
Oxytocin in cesarean-sections. What's new? |
spellingShingle |
Oxytocin in cesarean-sections. What's new? Yamaguchi,Eduardo Tsuyoshi Oxytocin Cesarean section Desensitization Dose |
title_short |
Oxytocin in cesarean-sections. What's new? |
title_full |
Oxytocin in cesarean-sections. What's new? |
title_fullStr |
Oxytocin in cesarean-sections. What's new? |
title_full_unstemmed |
Oxytocin in cesarean-sections. What's new? |
title_sort |
Oxytocin in cesarean-sections. What's new? |
author |
Yamaguchi,Eduardo Tsuyoshi |
author_facet |
Yamaguchi,Eduardo Tsuyoshi Siaulys,Mônica Maria Torres,Marcelo Luis Abramides |
author_role |
author |
author2 |
Siaulys,Mônica Maria Torres,Marcelo Luis Abramides |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Yamaguchi,Eduardo Tsuyoshi Siaulys,Mônica Maria Torres,Marcelo Luis Abramides |
dc.subject.por.fl_str_mv |
Oxytocin Cesarean section Desensitization Dose |
topic |
Oxytocin Cesarean section Desensitization Dose |
description |
Abstract Oxytocin is the uterotonic agent of choice in the prevention and treatment of postpartum uterine atony. Nevertheless, there is no consensus on the optimal dose and rate for use in cesarean sections. The use of high bolus doses (e.g., 10 IU of oxytocin) can determine deleterious cardiovascular changes for the patient, especially in situations of hypovolemia or low cardiac reserve. Furthermore, high doses of oxytocin for prolonged periods may lead to desensitization of oxytocin receptors in myometrium, resulting in clinical inefficiency. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942016000400402 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942016000400402 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1016/j.bjane.2014.11.015 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Anestesiologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Anestesiologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Anestesiologia v.66 n.4 2016 reponame:Revista Brasileira de Anestesiologia (Online) instname:Sociedade Brasileira de Anestesiologia (SBA) instacron:SBA |
instname_str |
Sociedade Brasileira de Anestesiologia (SBA) |
instacron_str |
SBA |
institution |
SBA |
reponame_str |
Revista Brasileira de Anestesiologia (Online) |
collection |
Revista Brasileira de Anestesiologia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA) |
repository.mail.fl_str_mv |
||sba2000@openlink.com.br |
_version_ |
1752126628975083520 |