Correlation of bispectral index (BIS) monitoring and end-tidal sevoflurane concentration in a patient with lobar holoprosencephaly

Detalhes bibliográficos
Autor(a) principal: Galante,Dario
Data de Publicação: 2015
Outros Autores: Fortarezza,Donatella, Caggiano,Maria, Francisci,Giovanni de, Pedrotti,Dino, Caruselli,Marco
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Anestesiologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942015000500379
Resumo: ABSTRACTOBJECTIVE: The bispectral index (BIS) is a parameter derived by electroencephalography (EEG) which provides a direct measurement of the effects of sedatives and anesthetics on the brain and offers guidance on the adequacy of anesthesia. The literature lacks studies on BIS monitoring in pediatric patients with congenital brain disease undergoing general anesthesia.CLINICAL FEATURES: A 13-year-old child weighing 32 kg, suffering from lobar holoprosencephaly, underwent surgery in which the bispectral index (BIS) monitoring the depth of anesthesia showed an abnormal response. Detailed analysis of the trends of BIS values in the different observation times demonstrated sudden falls and repetitive values of BIS likely related to repetitive epileptiform electrical activity caused by sevoflurane.CONCLUSION: The BIS is a very useful monitoring tool for assessing the degree of depth of anesthesia and to analyze the electroencephalographic variations of anesthetics. Particular attention should be given to patients with congenital disorders of the central nervous system in which the BIS may give abnormal responses that do not reflect an accurate assessment of the depth of anesthesia.
id SBA-1_b891ab7f3d3d77a98f46e8120b2a4490
oai_identifier_str oai:scielo:S0034-70942015000500379
network_acronym_str SBA-1
network_name_str Revista Brasileira de Anestesiologia (Online)
repository_id_str
spelling Correlation of bispectral index (BIS) monitoring and end-tidal sevoflurane concentration in a patient with lobar holoprosencephalyHoloprosencephalyBispectral indexSevofluraneSeizuresABSTRACTOBJECTIVE: The bispectral index (BIS) is a parameter derived by electroencephalography (EEG) which provides a direct measurement of the effects of sedatives and anesthetics on the brain and offers guidance on the adequacy of anesthesia. The literature lacks studies on BIS monitoring in pediatric patients with congenital brain disease undergoing general anesthesia.CLINICAL FEATURES: A 13-year-old child weighing 32 kg, suffering from lobar holoprosencephaly, underwent surgery in which the bispectral index (BIS) monitoring the depth of anesthesia showed an abnormal response. Detailed analysis of the trends of BIS values in the different observation times demonstrated sudden falls and repetitive values of BIS likely related to repetitive epileptiform electrical activity caused by sevoflurane.CONCLUSION: The BIS is a very useful monitoring tool for assessing the degree of depth of anesthesia and to analyze the electroencephalographic variations of anesthetics. Particular attention should be given to patients with congenital disorders of the central nervous system in which the BIS may give abnormal responses that do not reflect an accurate assessment of the depth of anesthesia.Sociedade Brasileira de Anestesiologia2015-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942015000500379Revista Brasileira de Anestesiologia v.65 n.5 2015reponame:Revista Brasileira de Anestesiologia (Online)instname:Sociedade Brasileira de Anestesiologia (SBA)instacron:SBA10.1016/j.bjane.2014.07.003info:eu-repo/semantics/openAccessGalante,DarioFortarezza,DonatellaCaggiano,MariaFrancisci,Giovanni dePedrotti,DinoCaruselli,Marcoeng2015-10-20T00:00:00Zoai:scielo:S0034-70942015000500379Revistahttps://www.sbahq.org/revista/https://old.scielo.br/oai/scielo-oai.php||sba2000@openlink.com.br1806-907X0034-7094opendoar:2015-10-20T00:00Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)false
dc.title.none.fl_str_mv Correlation of bispectral index (BIS) monitoring and end-tidal sevoflurane concentration in a patient with lobar holoprosencephaly
title Correlation of bispectral index (BIS) monitoring and end-tidal sevoflurane concentration in a patient with lobar holoprosencephaly
spellingShingle Correlation of bispectral index (BIS) monitoring and end-tidal sevoflurane concentration in a patient with lobar holoprosencephaly
Galante,Dario
Holoprosencephaly
Bispectral index
Sevoflurane
Seizures
title_short Correlation of bispectral index (BIS) monitoring and end-tidal sevoflurane concentration in a patient with lobar holoprosencephaly
title_full Correlation of bispectral index (BIS) monitoring and end-tidal sevoflurane concentration in a patient with lobar holoprosencephaly
title_fullStr Correlation of bispectral index (BIS) monitoring and end-tidal sevoflurane concentration in a patient with lobar holoprosencephaly
title_full_unstemmed Correlation of bispectral index (BIS) monitoring and end-tidal sevoflurane concentration in a patient with lobar holoprosencephaly
title_sort Correlation of bispectral index (BIS) monitoring and end-tidal sevoflurane concentration in a patient with lobar holoprosencephaly
author Galante,Dario
author_facet Galante,Dario
Fortarezza,Donatella
Caggiano,Maria
Francisci,Giovanni de
Pedrotti,Dino
Caruselli,Marco
author_role author
author2 Fortarezza,Donatella
Caggiano,Maria
Francisci,Giovanni de
Pedrotti,Dino
Caruselli,Marco
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Galante,Dario
Fortarezza,Donatella
Caggiano,Maria
Francisci,Giovanni de
Pedrotti,Dino
Caruselli,Marco
dc.subject.por.fl_str_mv Holoprosencephaly
Bispectral index
Sevoflurane
Seizures
topic Holoprosencephaly
Bispectral index
Sevoflurane
Seizures
description ABSTRACTOBJECTIVE: The bispectral index (BIS) is a parameter derived by electroencephalography (EEG) which provides a direct measurement of the effects of sedatives and anesthetics on the brain and offers guidance on the adequacy of anesthesia. The literature lacks studies on BIS monitoring in pediatric patients with congenital brain disease undergoing general anesthesia.CLINICAL FEATURES: A 13-year-old child weighing 32 kg, suffering from lobar holoprosencephaly, underwent surgery in which the bispectral index (BIS) monitoring the depth of anesthesia showed an abnormal response. Detailed analysis of the trends of BIS values in the different observation times demonstrated sudden falls and repetitive values of BIS likely related to repetitive epileptiform electrical activity caused by sevoflurane.CONCLUSION: The BIS is a very useful monitoring tool for assessing the degree of depth of anesthesia and to analyze the electroencephalographic variations of anesthetics. Particular attention should be given to patients with congenital disorders of the central nervous system in which the BIS may give abnormal responses that do not reflect an accurate assessment of the depth of anesthesia.
publishDate 2015
dc.date.none.fl_str_mv 2015-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942015000500379
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942015000500379
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.bjane.2014.07.003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Anestesiologia
publisher.none.fl_str_mv Sociedade Brasileira de Anestesiologia
dc.source.none.fl_str_mv Revista Brasileira de Anestesiologia v.65 n.5 2015
reponame:Revista Brasileira de Anestesiologia (Online)
instname:Sociedade Brasileira de Anestesiologia (SBA)
instacron:SBA
instname_str Sociedade Brasileira de Anestesiologia (SBA)
instacron_str SBA
institution SBA
reponame_str Revista Brasileira de Anestesiologia (Online)
collection Revista Brasileira de Anestesiologia (Online)
repository.name.fl_str_mv Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)
repository.mail.fl_str_mv ||sba2000@openlink.com.br
_version_ 1752126628559847424