Infection of expanded polytetrafluoroethylene and Dacron-coated stents with Staphylococcus epidermidis: an experimental study in pigs

Detalhes bibliográficos
Autor(a) principal: Dutra,Clandio de Freitas
Data de Publicação: 2021
Outros Autores: Pereira,Adamastor Humberto, Wollheim,Claudia, Pongiluppi,Rodrigo, Fellini,Roberto, Gomes Junior,Sérgio Ventura, Nonemacher,Henrique
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Jornal Vascular Brasileiro (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-54492021000100318
Resumo: Abstract Background Diagnosis of the etiologic agent of endoprosthesis infections is essential to enable treatment, since these infections constitute important complications of endovascular procedures. Sonication of explanted tissue and materials is a technique that can be used to facilitate detection of biofilm-producing bacteria. Objectives To evaluate infection of pigs' aortas after implantation of nitinol stents coated with polytetrafluoroethylene (ePTFE) or Dacron, previously infected with biofilm-producing Staphylococcus epidermidis. Intimal thickening and the inflammatory response in the aortic wall were also evaluated. Methods 11 ePTFE-coated nitinol stents and 10 Dacron stents infected with S. epidermidis strains were implanted in the infrarenal aorta of 21 8-week-old pigs. After 2 weeks, the aorta containing the stents was removed. A vortex mixer and ultrasound were used to homogenize the samples and remove the biofilm. Subsequently, the number of colony-forming units was counted. Results There were no significant differences between the two groups in terms of the number of colony-forming units or of inflammation in the arterial wall. With the exception of one specimen from the Dacron group, all aortic stent cultures were positive for S. epidermidis. Conclusions There were no significant differences in the inflammatory response or infection rate between ePTFE and Dacron-coated stents actively infected with biofilm-producing S. epidermidis. Intimal thickening and the inflammatory response to infection of endoprostheses were similar. These results suggest that the two most widely used stent lining materials have a similar infection rate.
id SBACV-1_2a60691ee695d08487edd3688d4d3752
oai_identifier_str oai:scielo:S1677-54492021000100318
network_acronym_str SBACV-1
network_name_str Jornal Vascular Brasileiro (Online)
repository_id_str
spelling Infection of expanded polytetrafluoroethylene and Dacron-coated stents with Staphylococcus epidermidis: an experimental study in pigsstentinfectionStaphylococcus epidermidisaortapigsAbstract Background Diagnosis of the etiologic agent of endoprosthesis infections is essential to enable treatment, since these infections constitute important complications of endovascular procedures. Sonication of explanted tissue and materials is a technique that can be used to facilitate detection of biofilm-producing bacteria. Objectives To evaluate infection of pigs' aortas after implantation of nitinol stents coated with polytetrafluoroethylene (ePTFE) or Dacron, previously infected with biofilm-producing Staphylococcus epidermidis. Intimal thickening and the inflammatory response in the aortic wall were also evaluated. Methods 11 ePTFE-coated nitinol stents and 10 Dacron stents infected with S. epidermidis strains were implanted in the infrarenal aorta of 21 8-week-old pigs. After 2 weeks, the aorta containing the stents was removed. A vortex mixer and ultrasound were used to homogenize the samples and remove the biofilm. Subsequently, the number of colony-forming units was counted. Results There were no significant differences between the two groups in terms of the number of colony-forming units or of inflammation in the arterial wall. With the exception of one specimen from the Dacron group, all aortic stent cultures were positive for S. epidermidis. Conclusions There were no significant differences in the inflammatory response or infection rate between ePTFE and Dacron-coated stents actively infected with biofilm-producing S. epidermidis. Intimal thickening and the inflammatory response to infection of endoprostheses were similar. These results suggest that the two most widely used stent lining materials have a similar infection rate.Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-54492021000100318Jornal Vascular Brasileiro v.20 2021reponame:Jornal Vascular Brasileiro (Online)instname:Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)instacron:SBACV10.1590/1677-5449.200157info:eu-repo/semantics/openAccessDutra,Clandio de FreitasPereira,Adamastor HumbertoWollheim,ClaudiaPongiluppi,RodrigoFellini,RobertoGomes Junior,Sérgio VenturaNonemacher,Henriqueeng2021-06-22T00:00:00Zoai:scielo:S1677-54492021000100318Revistahttp://www.scielo.br/jvbhttps://old.scielo.br/oai/scielo-oai.php||secretaria@sbacv.org.br1677-73011677-5449opendoar:2021-06-22T00:00Jornal Vascular Brasileiro (Online) - Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)false
dc.title.none.fl_str_mv Infection of expanded polytetrafluoroethylene and Dacron-coated stents with Staphylococcus epidermidis: an experimental study in pigs
title Infection of expanded polytetrafluoroethylene and Dacron-coated stents with Staphylococcus epidermidis: an experimental study in pigs
spellingShingle Infection of expanded polytetrafluoroethylene and Dacron-coated stents with Staphylococcus epidermidis: an experimental study in pigs
Dutra,Clandio de Freitas
stent
infection
Staphylococcus epidermidis
aorta
pigs
title_short Infection of expanded polytetrafluoroethylene and Dacron-coated stents with Staphylococcus epidermidis: an experimental study in pigs
title_full Infection of expanded polytetrafluoroethylene and Dacron-coated stents with Staphylococcus epidermidis: an experimental study in pigs
title_fullStr Infection of expanded polytetrafluoroethylene and Dacron-coated stents with Staphylococcus epidermidis: an experimental study in pigs
title_full_unstemmed Infection of expanded polytetrafluoroethylene and Dacron-coated stents with Staphylococcus epidermidis: an experimental study in pigs
title_sort Infection of expanded polytetrafluoroethylene and Dacron-coated stents with Staphylococcus epidermidis: an experimental study in pigs
author Dutra,Clandio de Freitas
author_facet Dutra,Clandio de Freitas
Pereira,Adamastor Humberto
Wollheim,Claudia
Pongiluppi,Rodrigo
Fellini,Roberto
Gomes Junior,Sérgio Ventura
Nonemacher,Henrique
author_role author
author2 Pereira,Adamastor Humberto
Wollheim,Claudia
Pongiluppi,Rodrigo
Fellini,Roberto
Gomes Junior,Sérgio Ventura
Nonemacher,Henrique
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Dutra,Clandio de Freitas
Pereira,Adamastor Humberto
Wollheim,Claudia
Pongiluppi,Rodrigo
Fellini,Roberto
Gomes Junior,Sérgio Ventura
Nonemacher,Henrique
dc.subject.por.fl_str_mv stent
infection
Staphylococcus epidermidis
aorta
pigs
topic stent
infection
Staphylococcus epidermidis
aorta
pigs
description Abstract Background Diagnosis of the etiologic agent of endoprosthesis infections is essential to enable treatment, since these infections constitute important complications of endovascular procedures. Sonication of explanted tissue and materials is a technique that can be used to facilitate detection of biofilm-producing bacteria. Objectives To evaluate infection of pigs' aortas after implantation of nitinol stents coated with polytetrafluoroethylene (ePTFE) or Dacron, previously infected with biofilm-producing Staphylococcus epidermidis. Intimal thickening and the inflammatory response in the aortic wall were also evaluated. Methods 11 ePTFE-coated nitinol stents and 10 Dacron stents infected with S. epidermidis strains were implanted in the infrarenal aorta of 21 8-week-old pigs. After 2 weeks, the aorta containing the stents was removed. A vortex mixer and ultrasound were used to homogenize the samples and remove the biofilm. Subsequently, the number of colony-forming units was counted. Results There were no significant differences between the two groups in terms of the number of colony-forming units or of inflammation in the arterial wall. With the exception of one specimen from the Dacron group, all aortic stent cultures were positive for S. epidermidis. Conclusions There were no significant differences in the inflammatory response or infection rate between ePTFE and Dacron-coated stents actively infected with biofilm-producing S. epidermidis. Intimal thickening and the inflammatory response to infection of endoprostheses were similar. These results suggest that the two most widely used stent lining materials have a similar infection rate.
publishDate 2021
dc.date.none.fl_str_mv 2021-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-54492021000100318
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-54492021000100318
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1677-5449.200157
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)
publisher.none.fl_str_mv Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)
dc.source.none.fl_str_mv Jornal Vascular Brasileiro v.20 2021
reponame:Jornal Vascular Brasileiro (Online)
instname:Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)
instacron:SBACV
instname_str Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)
instacron_str SBACV
institution SBACV
reponame_str Jornal Vascular Brasileiro (Online)
collection Jornal Vascular Brasileiro (Online)
repository.name.fl_str_mv Jornal Vascular Brasileiro (Online) - Sociedade Brasileira de Angiologia e de Cirurgia Vascular (SBACV)
repository.mail.fl_str_mv ||secretaria@sbacv.org.br
_version_ 1752126648874958848