Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block

Detalhes bibliográficos
Autor(a) principal: Costa,Roberto
Data de Publicação: 2017
Outros Autores: Silva,Katia Regina da, Martinelli Filho,Martino, Carrillo,Roger
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos Brasileiros de Cardiologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2017001300331
Resumo: Abstract Background: Few studies have characterized the surgical outcomes following epicardial pacemaker implantation in neonates with congenital complete atrioventricular block (CCAVB). Objective: This study sought to assess the long-term outcomes of a minimally invasive epicardial approach using a subxiphoid access for pacemaker implantation in neonates. Methods: Between July 2002 and February 2015, 16 consecutive neonates underwent epicardial pacemaker implantation due to CCAVB. Among these, 12 (75.0%) had congenital heart defects associated with CCAVB. The patients had a mean age of 4.7 ± 5.3 days and nine (56.3%) were female. Bipolar steroid-eluting epicardial leads were implanted in all patients through a minimally invasive subxiphoid approach and fixed on the diaphragmatic ventricular surface. The pulse generator was placed in an epigastric submuscular position. Results: All procedures were successful, with no perioperative complications or early deaths. Mean operating time was 90.2 ± 16.8 minutes. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 4.1 ± 3.9 years. Three children underwent pulse generator replacement due to normal battery depletion at 4.0, 7.2, and 9.0 years of age without the need of ventricular lead replacement. There were two deaths at 12 and 325 days after pacemaker implantation due to bleeding from thrombolytic use and progressive refractory heart failure, respectively. Conclusion: Epicardial pacemaker implantation through a subxiphoid approach in neonates with CCAVB is technically feasible and associated with excellent surgical outcomes and pacing lead longevity.
id SBC-1_0d99580f97cdc0ea8534d6d928df3ce5
oai_identifier_str oai:scielo:S0066-782X2017001300331
network_acronym_str SBC-1
network_name_str Arquivos Brasileiros de Cardiologia (Online)
repository_id_str
spelling Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart BlockHeart Defects, CongenitalInfants, NewbornsPacemaker, ArtificialAtrioventricular BlockAbstract Background: Few studies have characterized the surgical outcomes following epicardial pacemaker implantation in neonates with congenital complete atrioventricular block (CCAVB). Objective: This study sought to assess the long-term outcomes of a minimally invasive epicardial approach using a subxiphoid access for pacemaker implantation in neonates. Methods: Between July 2002 and February 2015, 16 consecutive neonates underwent epicardial pacemaker implantation due to CCAVB. Among these, 12 (75.0%) had congenital heart defects associated with CCAVB. The patients had a mean age of 4.7 ± 5.3 days and nine (56.3%) were female. Bipolar steroid-eluting epicardial leads were implanted in all patients through a minimally invasive subxiphoid approach and fixed on the diaphragmatic ventricular surface. The pulse generator was placed in an epigastric submuscular position. Results: All procedures were successful, with no perioperative complications or early deaths. Mean operating time was 90.2 ± 16.8 minutes. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 4.1 ± 3.9 years. Three children underwent pulse generator replacement due to normal battery depletion at 4.0, 7.2, and 9.0 years of age without the need of ventricular lead replacement. There were two deaths at 12 and 325 days after pacemaker implantation due to bleeding from thrombolytic use and progressive refractory heart failure, respectively. Conclusion: Epicardial pacemaker implantation through a subxiphoid approach in neonates with CCAVB is technically feasible and associated with excellent surgical outcomes and pacing lead longevity.Sociedade Brasileira de Cardiologia - SBC2017-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2017001300331Arquivos Brasileiros de Cardiologia v.109 n.4 2017reponame:Arquivos Brasileiros de Cardiologia (Online)instname:Sociedade Brasileira de Cardiologia (SBC)instacron:SBC10.5935/abc.20170126info:eu-repo/semantics/openAccessCosta,RobertoSilva,Katia Regina daMartinelli Filho,MartinoCarrillo,Rogereng2017-10-18T00:00:00Zoai:scielo:S0066-782X2017001300331Revistahttp://www.arquivosonline.com.br/https://old.scielo.br/oai/scielo-oai.php||arquivos@cardiol.br1678-41700066-782Xopendoar:2017-10-18T00:00Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)false
dc.title.none.fl_str_mv Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block
title Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block
spellingShingle Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block
Costa,Roberto
Heart Defects, Congenital
Infants, Newborns
Pacemaker, Artificial
Atrioventricular Block
title_short Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block
title_full Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block
title_fullStr Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block
title_full_unstemmed Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block
title_sort Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block
author Costa,Roberto
author_facet Costa,Roberto
Silva,Katia Regina da
Martinelli Filho,Martino
Carrillo,Roger
author_role author
author2 Silva,Katia Regina da
Martinelli Filho,Martino
Carrillo,Roger
author2_role author
author
author
dc.contributor.author.fl_str_mv Costa,Roberto
Silva,Katia Regina da
Martinelli Filho,Martino
Carrillo,Roger
dc.subject.por.fl_str_mv Heart Defects, Congenital
Infants, Newborns
Pacemaker, Artificial
Atrioventricular Block
topic Heart Defects, Congenital
Infants, Newborns
Pacemaker, Artificial
Atrioventricular Block
description Abstract Background: Few studies have characterized the surgical outcomes following epicardial pacemaker implantation in neonates with congenital complete atrioventricular block (CCAVB). Objective: This study sought to assess the long-term outcomes of a minimally invasive epicardial approach using a subxiphoid access for pacemaker implantation in neonates. Methods: Between July 2002 and February 2015, 16 consecutive neonates underwent epicardial pacemaker implantation due to CCAVB. Among these, 12 (75.0%) had congenital heart defects associated with CCAVB. The patients had a mean age of 4.7 ± 5.3 days and nine (56.3%) were female. Bipolar steroid-eluting epicardial leads were implanted in all patients through a minimally invasive subxiphoid approach and fixed on the diaphragmatic ventricular surface. The pulse generator was placed in an epigastric submuscular position. Results: All procedures were successful, with no perioperative complications or early deaths. Mean operating time was 90.2 ± 16.8 minutes. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 4.1 ± 3.9 years. Three children underwent pulse generator replacement due to normal battery depletion at 4.0, 7.2, and 9.0 years of age without the need of ventricular lead replacement. There were two deaths at 12 and 325 days after pacemaker implantation due to bleeding from thrombolytic use and progressive refractory heart failure, respectively. Conclusion: Epicardial pacemaker implantation through a subxiphoid approach in neonates with CCAVB is technically feasible and associated with excellent surgical outcomes and pacing lead longevity.
publishDate 2017
dc.date.none.fl_str_mv 2017-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2017001300331
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2017001300331
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/abc.20170126
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
dc.source.none.fl_str_mv Arquivos Brasileiros de Cardiologia v.109 n.4 2017
reponame:Arquivos Brasileiros de Cardiologia (Online)
instname:Sociedade Brasileira de Cardiologia (SBC)
instacron:SBC
instname_str Sociedade Brasileira de Cardiologia (SBC)
instacron_str SBC
institution SBC
reponame_str Arquivos Brasileiros de Cardiologia (Online)
collection Arquivos Brasileiros de Cardiologia (Online)
repository.name.fl_str_mv Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)
repository.mail.fl_str_mv ||arquivos@cardiol.br
_version_ 1752126567801159680