Cardiorespiratory Optimal Point in Professional Soccer Players: A Novel Submaximal Variable During Exercise

Detalhes bibliográficos
Autor(a) principal: Silva,Christina Grüne de Souza e
Data de Publicação: 2018
Outros Autores: Castro,Claudia Lucia Barros de, Franca,João Felipe, Bottino,Altamiro, Myers,Jonathan, Araújo,Claudio Gil Soares de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: International Journal of Cardiovascular Sciences (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2359-56472018000400323
Resumo: Abstract Background: Maximal oxygen consumption (VO2max) and ventilatory threshold (VT) obtained during a cardiopulmonary exercise test (CPX) are used in the evaluation of athletes. However, the identification of these variables may sometimes be unreliable, which limits their use. In contrast, the cardiorespiratory optimal point (COP) is a submaximal variable derived from CPX with objective measurement and prognostic significance. However, its behavior in athletes is unknown. Objective: To describe the behavior of COP in professional soccer players and its association with VO2max and VT. Methods: VO2max, VT and COP were obtained retrospectively from 198 soccer players undergoing maximal treadmill CPX using ramp protocol. COP was defined as the lowest value of the ventilation/oxygen consumption ratio in a given minute of the CPX. The soccer players were stratified according to their field position: goalkeeper, center-defender, left/right-back, midfielder and forwarder. Continuous variables were compared using unpaired Student t test or ANOVA, or Mann-Whitney test or Kruskal-Wallis test depending on their distribution, and categorical variables were compared using chi-square test. Pearson correlation was used to test the association between COP and other ventilatory variables. A level of 5% was used for statistical significance. Results: COP (mean ± SD) was 18.2 ± 2.1 and was achieved at a speed 4.3 ± 1.4 km.h-1 lower than that achieved at the VT. While VO2max (62.1 ± 6.2 mL.kg-1.min-1) tended to be lower in goalkeepers (p < 0.05), the COP did not vary according to field position (p = 0.41). No significant association was observed between COP and VO2max (r = 0.032, p = 0.65) or between COP and VT (r = -0.003, p = 0.96). Conclusion: COP can be easily determined during submaximal exercise performed with incremental speed in soccer players and does not vary according to the athlete’s field position. The absence of association with VO2max and VT indicates that COP provides distinct and complementary information to these variables. Future studies are needed to determine the practical implications of COP in assessing athletes. (Int J Cardiovasc Sci. 2018; [online].ahead print, PP.0-0)
id SBC-2_ab984d1c00e95456b52b06573d74c84e
oai_identifier_str oai:scielo:S2359-56472018000400323
network_acronym_str SBC-2
network_name_str International Journal of Cardiovascular Sciences (Online)
repository_id_str
spelling Cardiorespiratory Optimal Point in Professional Soccer Players: A Novel Submaximal Variable During ExerciseExerciseFootball / trendsSpirometry / methodsBronchospirometry / methodsAthletic PerformanceAbstract Background: Maximal oxygen consumption (VO2max) and ventilatory threshold (VT) obtained during a cardiopulmonary exercise test (CPX) are used in the evaluation of athletes. However, the identification of these variables may sometimes be unreliable, which limits their use. In contrast, the cardiorespiratory optimal point (COP) is a submaximal variable derived from CPX with objective measurement and prognostic significance. However, its behavior in athletes is unknown. Objective: To describe the behavior of COP in professional soccer players and its association with VO2max and VT. Methods: VO2max, VT and COP were obtained retrospectively from 198 soccer players undergoing maximal treadmill CPX using ramp protocol. COP was defined as the lowest value of the ventilation/oxygen consumption ratio in a given minute of the CPX. The soccer players were stratified according to their field position: goalkeeper, center-defender, left/right-back, midfielder and forwarder. Continuous variables were compared using unpaired Student t test or ANOVA, or Mann-Whitney test or Kruskal-Wallis test depending on their distribution, and categorical variables were compared using chi-square test. Pearson correlation was used to test the association between COP and other ventilatory variables. A level of 5% was used for statistical significance. Results: COP (mean ± SD) was 18.2 ± 2.1 and was achieved at a speed 4.3 ± 1.4 km.h-1 lower than that achieved at the VT. While VO2max (62.1 ± 6.2 mL.kg-1.min-1) tended to be lower in goalkeepers (p < 0.05), the COP did not vary according to field position (p = 0.41). No significant association was observed between COP and VO2max (r = 0.032, p = 0.65) or between COP and VT (r = -0.003, p = 0.96). Conclusion: COP can be easily determined during submaximal exercise performed with incremental speed in soccer players and does not vary according to the athlete’s field position. The absence of association with VO2max and VT indicates that COP provides distinct and complementary information to these variables. Future studies are needed to determine the practical implications of COP in assessing athletes. (Int J Cardiovasc Sci. 2018; [online].ahead print, PP.0-0)Sociedade Brasileira de Cardiologia2018-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2359-56472018000400323International Journal of Cardiovascular Sciences v.31 n.4 2018reponame:International Journal of Cardiovascular Sciences (Online)instname:Sociedade Brasileira de Cardiologia (SBC)instacron:SBC10.5935/2359-4802.20180030info:eu-repo/semantics/openAccessSilva,Christina Grüne de Souza eCastro,Claudia Lucia Barros deFranca,João FelipeBottino,AltamiroMyers,JonathanAraújo,Claudio Gil Soares deeng2018-07-12T00:00:00Zoai:scielo:S2359-56472018000400323Revistahttp://publicacoes.cardiol.br/portal/ijcshttps://old.scielo.br/oai/scielo-oai.phptailanerodrigues@cardiol.br||revistaijcs@cardiol.br2359-56472359-4802opendoar:2018-07-12T00:00International Journal of Cardiovascular Sciences (Online) - Sociedade Brasileira de Cardiologia (SBC)false
dc.title.none.fl_str_mv Cardiorespiratory Optimal Point in Professional Soccer Players: A Novel Submaximal Variable During Exercise
title Cardiorespiratory Optimal Point in Professional Soccer Players: A Novel Submaximal Variable During Exercise
spellingShingle Cardiorespiratory Optimal Point in Professional Soccer Players: A Novel Submaximal Variable During Exercise
Silva,Christina Grüne de Souza e
Exercise
Football / trends
Spirometry / methods
Bronchospirometry / methods
Athletic Performance
title_short Cardiorespiratory Optimal Point in Professional Soccer Players: A Novel Submaximal Variable During Exercise
title_full Cardiorespiratory Optimal Point in Professional Soccer Players: A Novel Submaximal Variable During Exercise
title_fullStr Cardiorespiratory Optimal Point in Professional Soccer Players: A Novel Submaximal Variable During Exercise
title_full_unstemmed Cardiorespiratory Optimal Point in Professional Soccer Players: A Novel Submaximal Variable During Exercise
title_sort Cardiorespiratory Optimal Point in Professional Soccer Players: A Novel Submaximal Variable During Exercise
author Silva,Christina Grüne de Souza e
author_facet Silva,Christina Grüne de Souza e
Castro,Claudia Lucia Barros de
Franca,João Felipe
Bottino,Altamiro
Myers,Jonathan
Araújo,Claudio Gil Soares de
author_role author
author2 Castro,Claudia Lucia Barros de
Franca,João Felipe
Bottino,Altamiro
Myers,Jonathan
Araújo,Claudio Gil Soares de
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Silva,Christina Grüne de Souza e
Castro,Claudia Lucia Barros de
Franca,João Felipe
Bottino,Altamiro
Myers,Jonathan
Araújo,Claudio Gil Soares de
dc.subject.por.fl_str_mv Exercise
Football / trends
Spirometry / methods
Bronchospirometry / methods
Athletic Performance
topic Exercise
Football / trends
Spirometry / methods
Bronchospirometry / methods
Athletic Performance
description Abstract Background: Maximal oxygen consumption (VO2max) and ventilatory threshold (VT) obtained during a cardiopulmonary exercise test (CPX) are used in the evaluation of athletes. However, the identification of these variables may sometimes be unreliable, which limits their use. In contrast, the cardiorespiratory optimal point (COP) is a submaximal variable derived from CPX with objective measurement and prognostic significance. However, its behavior in athletes is unknown. Objective: To describe the behavior of COP in professional soccer players and its association with VO2max and VT. Methods: VO2max, VT and COP were obtained retrospectively from 198 soccer players undergoing maximal treadmill CPX using ramp protocol. COP was defined as the lowest value of the ventilation/oxygen consumption ratio in a given minute of the CPX. The soccer players were stratified according to their field position: goalkeeper, center-defender, left/right-back, midfielder and forwarder. Continuous variables were compared using unpaired Student t test or ANOVA, or Mann-Whitney test or Kruskal-Wallis test depending on their distribution, and categorical variables were compared using chi-square test. Pearson correlation was used to test the association between COP and other ventilatory variables. A level of 5% was used for statistical significance. Results: COP (mean ± SD) was 18.2 ± 2.1 and was achieved at a speed 4.3 ± 1.4 km.h-1 lower than that achieved at the VT. While VO2max (62.1 ± 6.2 mL.kg-1.min-1) tended to be lower in goalkeepers (p < 0.05), the COP did not vary according to field position (p = 0.41). No significant association was observed between COP and VO2max (r = 0.032, p = 0.65) or between COP and VT (r = -0.003, p = 0.96). Conclusion: COP can be easily determined during submaximal exercise performed with incremental speed in soccer players and does not vary according to the athlete’s field position. The absence of association with VO2max and VT indicates that COP provides distinct and complementary information to these variables. Future studies are needed to determine the practical implications of COP in assessing athletes. (Int J Cardiovasc Sci. 2018; [online].ahead print, PP.0-0)
publishDate 2018
dc.date.none.fl_str_mv 2018-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2359-56472018000400323
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2359-56472018000400323
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/2359-4802.20180030
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia
publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia
dc.source.none.fl_str_mv International Journal of Cardiovascular Sciences v.31 n.4 2018
reponame:International Journal of Cardiovascular Sciences (Online)
instname:Sociedade Brasileira de Cardiologia (SBC)
instacron:SBC
instname_str Sociedade Brasileira de Cardiologia (SBC)
instacron_str SBC
institution SBC
reponame_str International Journal of Cardiovascular Sciences (Online)
collection International Journal of Cardiovascular Sciences (Online)
repository.name.fl_str_mv International Journal of Cardiovascular Sciences (Online) - Sociedade Brasileira de Cardiologia (SBC)
repository.mail.fl_str_mv tailanerodrigues@cardiol.br||revistaijcs@cardiol.br
_version_ 1754732625279320064