Single-Dose Lignocaine-Based Blood Cardioplegia in Single Valve Replacement Patients

Detalhes bibliográficos
Autor(a) principal: Ramani,Jaydip
Data de Publicação: 2017
Outros Autores: Malhotra,Amber, Wadhwa,Vivek, Sharma,Pranav, Garg,Pankaj, Tarsaria,Malkesh, Pandya,Himani
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Cardiovascular Surgery (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382017000200090
Resumo: Abstract OBJECTIVE: Myocardial protection is the most important in cardiac surgery. We compared our modified single-dose long-acting lignocaine-based blood cardioplegia with short-acting St Thomas 1 blood cardioplegia in patients undergoing single valve replacement. METHODS: A total of 110 patients who underwent single (aortic or mitral) valve replacement surgery were enrolled. Patients were divided in two groups based on the cardioplegia solution used. In group 1 (56 patients), long-acting lignocaine based-blood cardioplegia solution was administered as a single dose while in group 2 (54 patients), standard St Thomas IB (short-acting blood-based cardioplegia solution) was administered and repeated every 20 minutes. All the patients were compared for preoperative baseline parameters, intraoperative and all the postoperative parameters. RESULTS: We did not find any statistically significant difference in preoperative baseline parameters. Cardiopulmonary bypass time were 73.8±16.5 and 76.4±16.9 minutes (P=0.43) and cross clamp time were 58.9±10.3 and 66.3±11.2 minutes (P=0.23) in group 1 and group 2, respectively. Mean of maximum inotrope score was 6.3±2.52 and 6.1±2.13 (P=0.65) in group 1 and group 2, respectively. We also did not find any statistically significant difference in creatine-phosphokinase-MB (CPK-MB), Troponin-I levels, lactate level and cardiac functions postoperatively. CONCLUSION: This study proves the safety and efficacy of long-acting lignocaine-based single-dose blood cardioplegia compared to the standard short-acting multi-dose blood cardioplegia in patients requiring the single valve replacement. Further studies need to be undertaken to establish this non-inferiority in situations of complex cardiac procedures especially in compromised patients.
id SBCCV-1_975ea71683ad0db66bf3ec1b2b51f1bd
oai_identifier_str oai:scielo:S0102-76382017000200090
network_acronym_str SBCCV-1
network_name_str Brazilian Journal of Cardiovascular Surgery (Online)
repository_id_str
spelling Single-Dose Lignocaine-Based Blood Cardioplegia in Single Valve Replacement PatientsCardiopulmonary BypassCardioplegic SolutionsLidocaineHeart Valves/SurgeryAortic Valve/SurgeryMitral Valve/sSurgeryAbstract OBJECTIVE: Myocardial protection is the most important in cardiac surgery. We compared our modified single-dose long-acting lignocaine-based blood cardioplegia with short-acting St Thomas 1 blood cardioplegia in patients undergoing single valve replacement. METHODS: A total of 110 patients who underwent single (aortic or mitral) valve replacement surgery were enrolled. Patients were divided in two groups based on the cardioplegia solution used. In group 1 (56 patients), long-acting lignocaine based-blood cardioplegia solution was administered as a single dose while in group 2 (54 patients), standard St Thomas IB (short-acting blood-based cardioplegia solution) was administered and repeated every 20 minutes. All the patients were compared for preoperative baseline parameters, intraoperative and all the postoperative parameters. RESULTS: We did not find any statistically significant difference in preoperative baseline parameters. Cardiopulmonary bypass time were 73.8±16.5 and 76.4±16.9 minutes (P=0.43) and cross clamp time were 58.9±10.3 and 66.3±11.2 minutes (P=0.23) in group 1 and group 2, respectively. Mean of maximum inotrope score was 6.3±2.52 and 6.1±2.13 (P=0.65) in group 1 and group 2, respectively. We also did not find any statistically significant difference in creatine-phosphokinase-MB (CPK-MB), Troponin-I levels, lactate level and cardiac functions postoperatively. CONCLUSION: This study proves the safety and efficacy of long-acting lignocaine-based single-dose blood cardioplegia compared to the standard short-acting multi-dose blood cardioplegia in patients requiring the single valve replacement. Further studies need to be undertaken to establish this non-inferiority in situations of complex cardiac procedures especially in compromised patients.Sociedade Brasileira de Cirurgia Cardiovascular2017-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382017000200090Brazilian Journal of Cardiovascular Surgery v.32 n.2 2017reponame:Brazilian Journal of Cardiovascular Surgery (Online)instname:Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)instacron:SBCCV10.21470/1678-9741-2016-0025info:eu-repo/semantics/openAccessRamani,JaydipMalhotra,AmberWadhwa,VivekSharma,PranavGarg,PankajTarsaria,MalkeshPandya,Himanieng2017-12-01T00:00:00Zoai:scielo:S0102-76382017000200090Revistahttp://www.rbccv.org.br/https://old.scielo.br/oai/scielo-oai.php||rosangela.monteiro@incor.usp.br|| domingo@braile.com.br|| brandau@braile.com.br1678-97410102-7638opendoar:2017-12-01T00:00Brazilian Journal of Cardiovascular Surgery (Online) - Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)false
dc.title.none.fl_str_mv Single-Dose Lignocaine-Based Blood Cardioplegia in Single Valve Replacement Patients
title Single-Dose Lignocaine-Based Blood Cardioplegia in Single Valve Replacement Patients
spellingShingle Single-Dose Lignocaine-Based Blood Cardioplegia in Single Valve Replacement Patients
Ramani,Jaydip
Cardiopulmonary Bypass
Cardioplegic Solutions
Lidocaine
Heart Valves/Surgery
Aortic Valve/Surgery
Mitral Valve/sSurgery
title_short Single-Dose Lignocaine-Based Blood Cardioplegia in Single Valve Replacement Patients
title_full Single-Dose Lignocaine-Based Blood Cardioplegia in Single Valve Replacement Patients
title_fullStr Single-Dose Lignocaine-Based Blood Cardioplegia in Single Valve Replacement Patients
title_full_unstemmed Single-Dose Lignocaine-Based Blood Cardioplegia in Single Valve Replacement Patients
title_sort Single-Dose Lignocaine-Based Blood Cardioplegia in Single Valve Replacement Patients
author Ramani,Jaydip
author_facet Ramani,Jaydip
Malhotra,Amber
Wadhwa,Vivek
Sharma,Pranav
Garg,Pankaj
Tarsaria,Malkesh
Pandya,Himani
author_role author
author2 Malhotra,Amber
Wadhwa,Vivek
Sharma,Pranav
Garg,Pankaj
Tarsaria,Malkesh
Pandya,Himani
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Ramani,Jaydip
Malhotra,Amber
Wadhwa,Vivek
Sharma,Pranav
Garg,Pankaj
Tarsaria,Malkesh
Pandya,Himani
dc.subject.por.fl_str_mv Cardiopulmonary Bypass
Cardioplegic Solutions
Lidocaine
Heart Valves/Surgery
Aortic Valve/Surgery
Mitral Valve/sSurgery
topic Cardiopulmonary Bypass
Cardioplegic Solutions
Lidocaine
Heart Valves/Surgery
Aortic Valve/Surgery
Mitral Valve/sSurgery
description Abstract OBJECTIVE: Myocardial protection is the most important in cardiac surgery. We compared our modified single-dose long-acting lignocaine-based blood cardioplegia with short-acting St Thomas 1 blood cardioplegia in patients undergoing single valve replacement. METHODS: A total of 110 patients who underwent single (aortic or mitral) valve replacement surgery were enrolled. Patients were divided in two groups based on the cardioplegia solution used. In group 1 (56 patients), long-acting lignocaine based-blood cardioplegia solution was administered as a single dose while in group 2 (54 patients), standard St Thomas IB (short-acting blood-based cardioplegia solution) was administered and repeated every 20 minutes. All the patients were compared for preoperative baseline parameters, intraoperative and all the postoperative parameters. RESULTS: We did not find any statistically significant difference in preoperative baseline parameters. Cardiopulmonary bypass time were 73.8±16.5 and 76.4±16.9 minutes (P=0.43) and cross clamp time were 58.9±10.3 and 66.3±11.2 minutes (P=0.23) in group 1 and group 2, respectively. Mean of maximum inotrope score was 6.3±2.52 and 6.1±2.13 (P=0.65) in group 1 and group 2, respectively. We also did not find any statistically significant difference in creatine-phosphokinase-MB (CPK-MB), Troponin-I levels, lactate level and cardiac functions postoperatively. CONCLUSION: This study proves the safety and efficacy of long-acting lignocaine-based single-dose blood cardioplegia compared to the standard short-acting multi-dose blood cardioplegia in patients requiring the single valve replacement. Further studies need to be undertaken to establish this non-inferiority in situations of complex cardiac procedures especially in compromised patients.
publishDate 2017
dc.date.none.fl_str_mv 2017-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382017000200090
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382017000200090
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.21470/1678-9741-2016-0025
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Cirurgia Cardiovascular
publisher.none.fl_str_mv Sociedade Brasileira de Cirurgia Cardiovascular
dc.source.none.fl_str_mv Brazilian Journal of Cardiovascular Surgery v.32 n.2 2017
reponame:Brazilian Journal of Cardiovascular Surgery (Online)
instname:Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)
instacron:SBCCV
instname_str Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)
instacron_str SBCCV
institution SBCCV
reponame_str Brazilian Journal of Cardiovascular Surgery (Online)
collection Brazilian Journal of Cardiovascular Surgery (Online)
repository.name.fl_str_mv Brazilian Journal of Cardiovascular Surgery (Online) - Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)
repository.mail.fl_str_mv ||rosangela.monteiro@incor.usp.br|| domingo@braile.com.br|| brandau@braile.com.br
_version_ 1752126599487029248