The Beneficial Effect of Anticoagulation in Aortic Bioprosthesis is Associated with its Size

Detalhes bibliográficos
Autor(a) principal: Dayan,Victor
Data de Publicação: 2020
Outros Autores: Farachio,Paula, Arocena,Maria Jose, Fernandez,Amparo, Perez,Diego, Soca,Gerardo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Cardiovascular Surgery (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382020000300014
Resumo: Abstract Objective: To evaluate the clinical and echocardiographic outcomes in aortic valve replacement (AVR) patients with aortic bioprosthesis under oral anticoagulation (OA). Methods: Patients who underwent AVR with bioprosthesiswere prospectively enrolled. They were classified based on postoperative use of OA. Clinical and operative variables were collected. Echocardiographic and clinical follow-ups were performed two years after surgery. The primary outcome evaluated was change in transprosthetic gradient. Secondary outcomes analyzed were change in New York Heart Association (NYHA) class, major bleeding episodes, hospitalization, stroke, and transient ischemic attack. Results: We included 103 patients (61 without OA and 42 with OA). Clinical characteristics were similar among groups, except for younger age (76±6.3 vs. 72.4±8.1 years, P=0.016) and higher prevalence of atrial fibrillation (0% vs. 23.8%, P<0.001) in the OA group. Mean (21.4±10 mmHg vs. 16.8±7.7 mmHg, P=0.037) and maximum (33.4±13.7 mmHg vs. 28.4±10.2 mmHg, P=0.05) transprosthetic gradients were higher in patients without OA. Improvement in NYHA class was more frequent in patients with OA (73% vs. 45.3%, P=0.032). Major bleeding, stroke, and hospitalization were similar among groups. OA was the only independent predictor for improvement of NYHA class after multivariate logistic regression analysis (odds ratio [OR]: 5.9, 95% confidence interval [CI]: 1.2-29.4; P=0.028). Stratification by prosthesis size showed that patients with ≤ 21 mm prosthesis benefited from OA. Conclusion: Early anticoagulation after AVR with bioprosthesis was associated with significant decrease of transprosthesis gradient and improvement in NYHA class. These associations were seen mainly in patients with ≤ 21 mm prosthesis.
id SBCCV-1_f21d8788d23911cd5fb878932a34ae25
oai_identifier_str oai:scielo:S0102-76382020000300014
network_acronym_str SBCCV-1
network_name_str Brazilian Journal of Cardiovascular Surgery (Online)
repository_id_str
spelling The Beneficial Effect of Anticoagulation in Aortic Bioprosthesis is Associated with its SizeIschemic AttackTransientBioprosthesisAortic ValveAtrial FibrilationStrokeHemorrhageHospitalizationAbstract Objective: To evaluate the clinical and echocardiographic outcomes in aortic valve replacement (AVR) patients with aortic bioprosthesis under oral anticoagulation (OA). Methods: Patients who underwent AVR with bioprosthesiswere prospectively enrolled. They were classified based on postoperative use of OA. Clinical and operative variables were collected. Echocardiographic and clinical follow-ups were performed two years after surgery. The primary outcome evaluated was change in transprosthetic gradient. Secondary outcomes analyzed were change in New York Heart Association (NYHA) class, major bleeding episodes, hospitalization, stroke, and transient ischemic attack. Results: We included 103 patients (61 without OA and 42 with OA). Clinical characteristics were similar among groups, except for younger age (76±6.3 vs. 72.4±8.1 years, P=0.016) and higher prevalence of atrial fibrillation (0% vs. 23.8%, P<0.001) in the OA group. Mean (21.4±10 mmHg vs. 16.8±7.7 mmHg, P=0.037) and maximum (33.4±13.7 mmHg vs. 28.4±10.2 mmHg, P=0.05) transprosthetic gradients were higher in patients without OA. Improvement in NYHA class was more frequent in patients with OA (73% vs. 45.3%, P=0.032). Major bleeding, stroke, and hospitalization were similar among groups. OA was the only independent predictor for improvement of NYHA class after multivariate logistic regression analysis (odds ratio [OR]: 5.9, 95% confidence interval [CI]: 1.2-29.4; P=0.028). Stratification by prosthesis size showed that patients with ≤ 21 mm prosthesis benefited from OA. Conclusion: Early anticoagulation after AVR with bioprosthesis was associated with significant decrease of transprosthesis gradient and improvement in NYHA class. These associations were seen mainly in patients with ≤ 21 mm prosthesis.Sociedade Brasileira de Cirurgia Cardiovascular2020-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382020000300014Brazilian Journal of Cardiovascular Surgery v.35 n.3 2020reponame:Brazilian Journal of Cardiovascular Surgery (Online)instname:Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)instacron:SBCCV10.21470/1678-9741-2019-0144info:eu-repo/semantics/openAccessDayan,VictorFarachio,PaulaArocena,Maria JoseFernandez,AmparoPerez,DiegoSoca,Gerardoeng2020-06-05T00:00:00Zoai:scielo:S0102-76382020000300014Revistahttp://www.rbccv.org.br/https://old.scielo.br/oai/scielo-oai.php||rosangela.monteiro@incor.usp.br|| domingo@braile.com.br|| brandau@braile.com.br1678-97410102-7638opendoar:2020-06-05T00:00Brazilian Journal of Cardiovascular Surgery (Online) - Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)false
dc.title.none.fl_str_mv The Beneficial Effect of Anticoagulation in Aortic Bioprosthesis is Associated with its Size
title The Beneficial Effect of Anticoagulation in Aortic Bioprosthesis is Associated with its Size
spellingShingle The Beneficial Effect of Anticoagulation in Aortic Bioprosthesis is Associated with its Size
Dayan,Victor
Ischemic Attack
Transient
Bioprosthesis
Aortic Valve
Atrial Fibrilation
Stroke
Hemorrhage
Hospitalization
title_short The Beneficial Effect of Anticoagulation in Aortic Bioprosthesis is Associated with its Size
title_full The Beneficial Effect of Anticoagulation in Aortic Bioprosthesis is Associated with its Size
title_fullStr The Beneficial Effect of Anticoagulation in Aortic Bioprosthesis is Associated with its Size
title_full_unstemmed The Beneficial Effect of Anticoagulation in Aortic Bioprosthesis is Associated with its Size
title_sort The Beneficial Effect of Anticoagulation in Aortic Bioprosthesis is Associated with its Size
author Dayan,Victor
author_facet Dayan,Victor
Farachio,Paula
Arocena,Maria Jose
Fernandez,Amparo
Perez,Diego
Soca,Gerardo
author_role author
author2 Farachio,Paula
Arocena,Maria Jose
Fernandez,Amparo
Perez,Diego
Soca,Gerardo
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Dayan,Victor
Farachio,Paula
Arocena,Maria Jose
Fernandez,Amparo
Perez,Diego
Soca,Gerardo
dc.subject.por.fl_str_mv Ischemic Attack
Transient
Bioprosthesis
Aortic Valve
Atrial Fibrilation
Stroke
Hemorrhage
Hospitalization
topic Ischemic Attack
Transient
Bioprosthesis
Aortic Valve
Atrial Fibrilation
Stroke
Hemorrhage
Hospitalization
description Abstract Objective: To evaluate the clinical and echocardiographic outcomes in aortic valve replacement (AVR) patients with aortic bioprosthesis under oral anticoagulation (OA). Methods: Patients who underwent AVR with bioprosthesiswere prospectively enrolled. They were classified based on postoperative use of OA. Clinical and operative variables were collected. Echocardiographic and clinical follow-ups were performed two years after surgery. The primary outcome evaluated was change in transprosthetic gradient. Secondary outcomes analyzed were change in New York Heart Association (NYHA) class, major bleeding episodes, hospitalization, stroke, and transient ischemic attack. Results: We included 103 patients (61 without OA and 42 with OA). Clinical characteristics were similar among groups, except for younger age (76±6.3 vs. 72.4±8.1 years, P=0.016) and higher prevalence of atrial fibrillation (0% vs. 23.8%, P<0.001) in the OA group. Mean (21.4±10 mmHg vs. 16.8±7.7 mmHg, P=0.037) and maximum (33.4±13.7 mmHg vs. 28.4±10.2 mmHg, P=0.05) transprosthetic gradients were higher in patients without OA. Improvement in NYHA class was more frequent in patients with OA (73% vs. 45.3%, P=0.032). Major bleeding, stroke, and hospitalization were similar among groups. OA was the only independent predictor for improvement of NYHA class after multivariate logistic regression analysis (odds ratio [OR]: 5.9, 95% confidence interval [CI]: 1.2-29.4; P=0.028). Stratification by prosthesis size showed that patients with ≤ 21 mm prosthesis benefited from OA. Conclusion: Early anticoagulation after AVR with bioprosthesis was associated with significant decrease of transprosthesis gradient and improvement in NYHA class. These associations were seen mainly in patients with ≤ 21 mm prosthesis.
publishDate 2020
dc.date.none.fl_str_mv 2020-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382020000300014
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382020000300014
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.21470/1678-9741-2019-0144
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Cirurgia Cardiovascular
publisher.none.fl_str_mv Sociedade Brasileira de Cirurgia Cardiovascular
dc.source.none.fl_str_mv Brazilian Journal of Cardiovascular Surgery v.35 n.3 2020
reponame:Brazilian Journal of Cardiovascular Surgery (Online)
instname:Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)
instacron:SBCCV
instname_str Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)
instacron_str SBCCV
institution SBCCV
reponame_str Brazilian Journal of Cardiovascular Surgery (Online)
collection Brazilian Journal of Cardiovascular Surgery (Online)
repository.name.fl_str_mv Brazilian Journal of Cardiovascular Surgery (Online) - Sociedade Brasileira de Cirurgia Cardiovascular (SBCCV)
repository.mail.fl_str_mv ||rosangela.monteiro@incor.usp.br|| domingo@braile.com.br|| brandau@braile.com.br
_version_ 1752126601720496128