Alternative animal model for studies of total skin thickness burns
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Acta Cirúrgica Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502017001000836 |
Resumo: | Abstract Purpose: To present an alternative experimental model of third degree burn of easy reproducibility. Methods: Eighteen male Wister rats were randomly divided into three groups, 6 of which were allocated to each group. A soldering iron coupled to an aluminum plate was used to produce burn, at a temperature of 150ºC, with different exposure times per group. Group 5 (G5) animals were burned at 150°C with exposure time of 5 seconds; Group 10 (G10) the animals were burned at 150°C with exposure time of 10 seconds and group 15 (G15) the animals were burned at 150°C with exposure time of 15 seconds. Results: Histopathological analyzes showed that all three groups had similar morphological characteristics, with total thickness involvement. Conclusion: The technique is effective to reproduce a third degree burn and suggests the temperature of 150ºC with 5 seconds of exposure in order to minimize the risks to the animals. |
id |
SBDPC-1_5c901781f847fdd047cb10193c8ce278 |
---|---|
oai_identifier_str |
oai:scielo:S0102-86502017001000836 |
network_acronym_str |
SBDPC-1 |
network_name_str |
Acta Cirúrgica Brasileira (Online) |
repository_id_str |
|
spelling |
Alternative animal model for studies of total skin thickness burnsBurnsModels, AnimalSkinRatsAbstract Purpose: To present an alternative experimental model of third degree burn of easy reproducibility. Methods: Eighteen male Wister rats were randomly divided into three groups, 6 of which were allocated to each group. A soldering iron coupled to an aluminum plate was used to produce burn, at a temperature of 150ºC, with different exposure times per group. Group 5 (G5) animals were burned at 150°C with exposure time of 5 seconds; Group 10 (G10) the animals were burned at 150°C with exposure time of 10 seconds and group 15 (G15) the animals were burned at 150°C with exposure time of 15 seconds. Results: Histopathological analyzes showed that all three groups had similar morphological characteristics, with total thickness involvement. Conclusion: The technique is effective to reproduce a third degree burn and suggests the temperature of 150ºC with 5 seconds of exposure in order to minimize the risks to the animals.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2017-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502017001000836Acta Cirúrgica Brasileira v.32 n.10 2017reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/s0102-865020170100000005info:eu-repo/semantics/openAccessAndrade,Ana Laura Martins deParisi,Julia RissoBrassolatti,PatríciaParizotto,Nivaldo Antonioeng2017-11-08T00:00:00Zoai:scielo:S0102-86502017001000836Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2017-11-08T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false |
dc.title.none.fl_str_mv |
Alternative animal model for studies of total skin thickness burns |
title |
Alternative animal model for studies of total skin thickness burns |
spellingShingle |
Alternative animal model for studies of total skin thickness burns Andrade,Ana Laura Martins de Burns Models, Animal Skin Rats |
title_short |
Alternative animal model for studies of total skin thickness burns |
title_full |
Alternative animal model for studies of total skin thickness burns |
title_fullStr |
Alternative animal model for studies of total skin thickness burns |
title_full_unstemmed |
Alternative animal model for studies of total skin thickness burns |
title_sort |
Alternative animal model for studies of total skin thickness burns |
author |
Andrade,Ana Laura Martins de |
author_facet |
Andrade,Ana Laura Martins de Parisi,Julia Risso Brassolatti,Patrícia Parizotto,Nivaldo Antonio |
author_role |
author |
author2 |
Parisi,Julia Risso Brassolatti,Patrícia Parizotto,Nivaldo Antonio |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Andrade,Ana Laura Martins de Parisi,Julia Risso Brassolatti,Patrícia Parizotto,Nivaldo Antonio |
dc.subject.por.fl_str_mv |
Burns Models, Animal Skin Rats |
topic |
Burns Models, Animal Skin Rats |
description |
Abstract Purpose: To present an alternative experimental model of third degree burn of easy reproducibility. Methods: Eighteen male Wister rats were randomly divided into three groups, 6 of which were allocated to each group. A soldering iron coupled to an aluminum plate was used to produce burn, at a temperature of 150ºC, with different exposure times per group. Group 5 (G5) animals were burned at 150°C with exposure time of 5 seconds; Group 10 (G10) the animals were burned at 150°C with exposure time of 10 seconds and group 15 (G15) the animals were burned at 150°C with exposure time of 15 seconds. Results: Histopathological analyzes showed that all three groups had similar morphological characteristics, with total thickness involvement. Conclusion: The technique is effective to reproduce a third degree burn and suggests the temperature of 150ºC with 5 seconds of exposure in order to minimize the risks to the animals. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502017001000836 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502017001000836 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/s0102-865020170100000005 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
dc.source.none.fl_str_mv |
Acta Cirúrgica Brasileira v.32 n.10 2017 reponame:Acta Cirúrgica Brasileira (Online) instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) instacron:SBDPC |
instname_str |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
instacron_str |
SBDPC |
institution |
SBDPC |
reponame_str |
Acta Cirúrgica Brasileira (Online) |
collection |
Acta Cirúrgica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
repository.mail.fl_str_mv |
||sgolden@terra.com.br |
_version_ |
1752126444516933632 |