Guinea pigs as experimental model to evaluate the resistance of the tissue expander capsule

Detalhes bibliográficos
Autor(a) principal: Nahas,Fábio Xerfan
Data de Publicação: 2004
Outros Autores: Vasconez,Luis O., Ferreira,Lydia Masako
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Cirúrgica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502004000700016
Resumo: The purpose of this study is to report the use of guinea pigs as experimental model to study the resitance of the tissue expander capsule. Two groups were studied. In both groups a round 20 cc tissue expander, attached to a multiperforated catheter was inserted. The pocket housing was standardized. The skin over the expanded area was tattooed demarcating the area and arc, which were measured before and after each expansion. Every 4 days, a volume corresponding to 10% of the expander's total capacity was injected. Animals of the control group received 3 cc of saline through the catheter at the same time of expansion. Animals of the experimental group received 3 cc of the HBGF-1 diluted with saline. The intraluminal pressure of the expander was measured before and after the injection. After its total filling, the animals were sacrificed and 5 cc more were injected into each expander. The pressure was measured after each 1 cc injected. The capsule was examined histologically by immunofluorescence, trichrome and hematoxylin-eosin stains with the purpose of quantifying collagen and fibroblasts. The experimental model to study the resistance of the tissue expander's capsule showed to be feasible in guinea pigs.
id SBDPC-1_fb6d5f1c2da05ebd62e31a5971e1aa02
oai_identifier_str oai:scielo:S0102-86502004000700016
network_acronym_str SBDPC-1
network_name_str Acta Cirúrgica Brasileira (Online)
repository_id_str
spelling Guinea pigs as experimental model to evaluate the resistance of the tissue expander capsuleGuinea pigsCapsular contractureTissue expanderHBGF-1The purpose of this study is to report the use of guinea pigs as experimental model to study the resitance of the tissue expander capsule. Two groups were studied. In both groups a round 20 cc tissue expander, attached to a multiperforated catheter was inserted. The pocket housing was standardized. The skin over the expanded area was tattooed demarcating the area and arc, which were measured before and after each expansion. Every 4 days, a volume corresponding to 10% of the expander's total capacity was injected. Animals of the control group received 3 cc of saline through the catheter at the same time of expansion. Animals of the experimental group received 3 cc of the HBGF-1 diluted with saline. The intraluminal pressure of the expander was measured before and after the injection. After its total filling, the animals were sacrificed and 5 cc more were injected into each expander. The pressure was measured after each 1 cc injected. The capsule was examined histologically by immunofluorescence, trichrome and hematoxylin-eosin stains with the purpose of quantifying collagen and fibroblasts. The experimental model to study the resistance of the tissue expander's capsule showed to be feasible in guinea pigs.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2004-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502004000700016Acta Cirúrgica Brasileira v.19 suppl.1 2004reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-86502004000700016info:eu-repo/semantics/openAccessNahas,Fábio XerfanVasconez,Luis O.Ferreira,Lydia Masakoeng2005-03-17T00:00:00Zoai:scielo:S0102-86502004000700016Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2005-03-17T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false
dc.title.none.fl_str_mv Guinea pigs as experimental model to evaluate the resistance of the tissue expander capsule
title Guinea pigs as experimental model to evaluate the resistance of the tissue expander capsule
spellingShingle Guinea pigs as experimental model to evaluate the resistance of the tissue expander capsule
Nahas,Fábio Xerfan
Guinea pigs
Capsular contracture
Tissue expander
HBGF-1
title_short Guinea pigs as experimental model to evaluate the resistance of the tissue expander capsule
title_full Guinea pigs as experimental model to evaluate the resistance of the tissue expander capsule
title_fullStr Guinea pigs as experimental model to evaluate the resistance of the tissue expander capsule
title_full_unstemmed Guinea pigs as experimental model to evaluate the resistance of the tissue expander capsule
title_sort Guinea pigs as experimental model to evaluate the resistance of the tissue expander capsule
author Nahas,Fábio Xerfan
author_facet Nahas,Fábio Xerfan
Vasconez,Luis O.
Ferreira,Lydia Masako
author_role author
author2 Vasconez,Luis O.
Ferreira,Lydia Masako
author2_role author
author
dc.contributor.author.fl_str_mv Nahas,Fábio Xerfan
Vasconez,Luis O.
Ferreira,Lydia Masako
dc.subject.por.fl_str_mv Guinea pigs
Capsular contracture
Tissue expander
HBGF-1
topic Guinea pigs
Capsular contracture
Tissue expander
HBGF-1
description The purpose of this study is to report the use of guinea pigs as experimental model to study the resitance of the tissue expander capsule. Two groups were studied. In both groups a round 20 cc tissue expander, attached to a multiperforated catheter was inserted. The pocket housing was standardized. The skin over the expanded area was tattooed demarcating the area and arc, which were measured before and after each expansion. Every 4 days, a volume corresponding to 10% of the expander's total capacity was injected. Animals of the control group received 3 cc of saline through the catheter at the same time of expansion. Animals of the experimental group received 3 cc of the HBGF-1 diluted with saline. The intraluminal pressure of the expander was measured before and after the injection. After its total filling, the animals were sacrificed and 5 cc more were injected into each expander. The pressure was measured after each 1 cc injected. The capsule was examined histologically by immunofluorescence, trichrome and hematoxylin-eosin stains with the purpose of quantifying collagen and fibroblasts. The experimental model to study the resistance of the tissue expander's capsule showed to be feasible in guinea pigs.
publishDate 2004
dc.date.none.fl_str_mv 2004-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502004000700016
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502004000700016
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0102-86502004000700016
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.source.none.fl_str_mv Acta Cirúrgica Brasileira v.19 suppl.1 2004
reponame:Acta Cirúrgica Brasileira (Online)
instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron:SBDPC
instname_str Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron_str SBDPC
institution SBDPC
reponame_str Acta Cirúrgica Brasileira (Online)
collection Acta Cirúrgica Brasileira (Online)
repository.name.fl_str_mv Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
repository.mail.fl_str_mv ||sgolden@terra.com.br
_version_ 1752126437380325376