THERMAL EFFICIENCY OF DIFFERENT COVERAGE MATERIALS IN REDUCED MODELS OF ANIMAL HUSBANDRY FACILITIES: A CASE STUDY
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Engenharia Agrícola |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162017000300403 |
Resumo: | ABSTRACT This study aimed to assess different combinations of coverage materials in reduced models of animal husbandry facilities based on thermal comfort indices. It was conducted in an experimental area of the Research Center in Ambience located in São Paulo State, Brazil (22°42′30″ S and 47°38′00″ W). The performance of ceramic and fiber-cement (white painted) tiles was assessed associated with two types of polypropylene commercial linings (lining A and B) installed below the roof, and a thermo-reflective screen (lining C) installed above the fiber-cement roof. Microclimatic assessment of distorted reduced-scale models was performed at 15-minute intervals by registering the air temperature, black globe temperature, relative humidity and air velocity. Subsequently, black globe humidity index, specific enthalpy, and radiant heat load were calculated. The experimental design was randomized block design with 5 treatments and 15 blocks (replications), totaling 75 experimental units. The reduced-scale models with lining B presented a reduction for all thermal comfort indices. Lining C, installed on the coverage, showed no upgrading of environmental thermal conditions. Thus, lining B presented a better thermal performance regardless the tile type. |
id |
SBEA-1_742281bc8e1255b49fe67e535b39c33a |
---|---|
oai_identifier_str |
oai:scielo:S0100-69162017000300403 |
network_acronym_str |
SBEA-1 |
network_name_str |
Engenharia Agrícola |
repository_id_str |
|
spelling |
THERMAL EFFICIENCY OF DIFFERENT COVERAGE MATERIALS IN REDUCED MODELS OF ANIMAL HUSBANDRY FACILITIES: A CASE STUDYambiencethermal comforttilespoultry facilityliningsABSTRACT This study aimed to assess different combinations of coverage materials in reduced models of animal husbandry facilities based on thermal comfort indices. It was conducted in an experimental area of the Research Center in Ambience located in São Paulo State, Brazil (22°42′30″ S and 47°38′00″ W). The performance of ceramic and fiber-cement (white painted) tiles was assessed associated with two types of polypropylene commercial linings (lining A and B) installed below the roof, and a thermo-reflective screen (lining C) installed above the fiber-cement roof. Microclimatic assessment of distorted reduced-scale models was performed at 15-minute intervals by registering the air temperature, black globe temperature, relative humidity and air velocity. Subsequently, black globe humidity index, specific enthalpy, and radiant heat load were calculated. The experimental design was randomized block design with 5 treatments and 15 blocks (replications), totaling 75 experimental units. The reduced-scale models with lining B presented a reduction for all thermal comfort indices. Lining C, installed on the coverage, showed no upgrading of environmental thermal conditions. Thus, lining B presented a better thermal performance regardless the tile type.Associação Brasileira de Engenharia Agrícola2017-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162017000300403Engenharia Agrícola v.37 n.3 2017reponame:Engenharia Agrícolainstname:Associação Brasileira de Engenharia Agrícola (SBEA)instacron:SBEA10.1590/1809-4430-eng.agric.v37n3p403-413/2017info:eu-repo/semantics/openAccessCastro,Ariane C. deSilva,Iran J. O. daNazareno,Aérica C.Nunes,Maria L. A.Piedade,Sônia M. de S.eng2017-11-17T00:00:00Zoai:scielo:S0100-69162017000300403Revistahttp://www.engenhariaagricola.org.br/ORGhttps://old.scielo.br/oai/scielo-oai.phprevistasbea@sbea.org.br||sbea@sbea.org.br1809-44300100-6916opendoar:2017-11-17T00:00Engenharia Agrícola - Associação Brasileira de Engenharia Agrícola (SBEA)false |
dc.title.none.fl_str_mv |
THERMAL EFFICIENCY OF DIFFERENT COVERAGE MATERIALS IN REDUCED MODELS OF ANIMAL HUSBANDRY FACILITIES: A CASE STUDY |
title |
THERMAL EFFICIENCY OF DIFFERENT COVERAGE MATERIALS IN REDUCED MODELS OF ANIMAL HUSBANDRY FACILITIES: A CASE STUDY |
spellingShingle |
THERMAL EFFICIENCY OF DIFFERENT COVERAGE MATERIALS IN REDUCED MODELS OF ANIMAL HUSBANDRY FACILITIES: A CASE STUDY Castro,Ariane C. de ambience thermal comfort tiles poultry facility linings |
title_short |
THERMAL EFFICIENCY OF DIFFERENT COVERAGE MATERIALS IN REDUCED MODELS OF ANIMAL HUSBANDRY FACILITIES: A CASE STUDY |
title_full |
THERMAL EFFICIENCY OF DIFFERENT COVERAGE MATERIALS IN REDUCED MODELS OF ANIMAL HUSBANDRY FACILITIES: A CASE STUDY |
title_fullStr |
THERMAL EFFICIENCY OF DIFFERENT COVERAGE MATERIALS IN REDUCED MODELS OF ANIMAL HUSBANDRY FACILITIES: A CASE STUDY |
title_full_unstemmed |
THERMAL EFFICIENCY OF DIFFERENT COVERAGE MATERIALS IN REDUCED MODELS OF ANIMAL HUSBANDRY FACILITIES: A CASE STUDY |
title_sort |
THERMAL EFFICIENCY OF DIFFERENT COVERAGE MATERIALS IN REDUCED MODELS OF ANIMAL HUSBANDRY FACILITIES: A CASE STUDY |
author |
Castro,Ariane C. de |
author_facet |
Castro,Ariane C. de Silva,Iran J. O. da Nazareno,Aérica C. Nunes,Maria L. A. Piedade,Sônia M. de S. |
author_role |
author |
author2 |
Silva,Iran J. O. da Nazareno,Aérica C. Nunes,Maria L. A. Piedade,Sônia M. de S. |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Castro,Ariane C. de Silva,Iran J. O. da Nazareno,Aérica C. Nunes,Maria L. A. Piedade,Sônia M. de S. |
dc.subject.por.fl_str_mv |
ambience thermal comfort tiles poultry facility linings |
topic |
ambience thermal comfort tiles poultry facility linings |
description |
ABSTRACT This study aimed to assess different combinations of coverage materials in reduced models of animal husbandry facilities based on thermal comfort indices. It was conducted in an experimental area of the Research Center in Ambience located in São Paulo State, Brazil (22°42′30″ S and 47°38′00″ W). The performance of ceramic and fiber-cement (white painted) tiles was assessed associated with two types of polypropylene commercial linings (lining A and B) installed below the roof, and a thermo-reflective screen (lining C) installed above the fiber-cement roof. Microclimatic assessment of distorted reduced-scale models was performed at 15-minute intervals by registering the air temperature, black globe temperature, relative humidity and air velocity. Subsequently, black globe humidity index, specific enthalpy, and radiant heat load were calculated. The experimental design was randomized block design with 5 treatments and 15 blocks (replications), totaling 75 experimental units. The reduced-scale models with lining B presented a reduction for all thermal comfort indices. Lining C, installed on the coverage, showed no upgrading of environmental thermal conditions. Thus, lining B presented a better thermal performance regardless the tile type. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162017000300403 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69162017000300403 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1809-4430-eng.agric.v37n3p403-413/2017 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Engenharia Agrícola |
publisher.none.fl_str_mv |
Associação Brasileira de Engenharia Agrícola |
dc.source.none.fl_str_mv |
Engenharia Agrícola v.37 n.3 2017 reponame:Engenharia Agrícola instname:Associação Brasileira de Engenharia Agrícola (SBEA) instacron:SBEA |
instname_str |
Associação Brasileira de Engenharia Agrícola (SBEA) |
instacron_str |
SBEA |
institution |
SBEA |
reponame_str |
Engenharia Agrícola |
collection |
Engenharia Agrícola |
repository.name.fl_str_mv |
Engenharia Agrícola - Associação Brasileira de Engenharia Agrícola (SBEA) |
repository.mail.fl_str_mv |
revistasbea@sbea.org.br||sbea@sbea.org.br |
_version_ |
1752126273223655424 |