Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | , , , , |
Tipo de documento: | Relatório |
Idioma: | eng |
Título da fonte: | Arquivos Brasileiros de Endocrinologia & Metabologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27302007000700021 |
Resumo: | Parathyroid scintigraphies have been used to detect pathological parathyroid glands either before as well as after the parathyroid resection surgery in patients with hyperparathyroidism. One of the most utilized techniques to perform the studies is the double-phase images with Tc-99m sestamibi, which has been shown to be very accurate in the localization of enlarged parathyroid glands. Similar to Tc-99m sestamibi, Tc-99m tetrofosmin is a radiopharmaceutical initially developed to perform myocardial perfusion study that has been used to perform parathyroid scintigraphies. Although most of the papers suggest that the overall sensitivities of both radiopharmaceuticals are similar, there are some papers questioning the accuracy of Tc-99m tetrofosmin to detect abnormal parathyroid glands. In the present article, we report a case with discordant results by both methods. |
id |
SBEM-2_e10f35573d0f8e5d9d4563854570bc89 |
---|---|
oai_identifier_str |
oai:scielo:S0004-27302007000700021 |
network_acronym_str |
SBEM-2 |
network_name_str |
Arquivos Brasileiros de Endocrinologia & Metabologia (Online) |
repository_id_str |
|
spelling |
Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphiesScintigraphyParathyroidMIBISestamibiTetrofosminParathyroid scintigraphies have been used to detect pathological parathyroid glands either before as well as after the parathyroid resection surgery in patients with hyperparathyroidism. One of the most utilized techniques to perform the studies is the double-phase images with Tc-99m sestamibi, which has been shown to be very accurate in the localization of enlarged parathyroid glands. Similar to Tc-99m sestamibi, Tc-99m tetrofosmin is a radiopharmaceutical initially developed to perform myocardial perfusion study that has been used to perform parathyroid scintigraphies. Although most of the papers suggest that the overall sensitivities of both radiopharmaceuticals are similar, there are some papers questioning the accuracy of Tc-99m tetrofosmin to detect abnormal parathyroid glands. In the present article, we report a case with discordant results by both methods.Sociedade Brasileira de Endocrinologia e Metabologia2007-10-01info:eu-repo/semantics/reportinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27302007000700021Arquivos Brasileiros de Endocrinologia & Metabologia v.51 n.7 2007reponame:Arquivos Brasileiros de Endocrinologia & Metabologia (Online)instname:Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)instacron:SBEM10.1590/S0004-27302007000700021info:eu-repo/semantics/openAccessDuarte,Paulo SchiavomDomingues,Fernanda C.Costa,Michele SantiBrandão,CynthiaOliveira,Marco A.C. deVieira,José G.H.eng2007-12-17T00:00:00Zoai:scielo:S0004-27302007000700021Revistahttps://www.aem-sbem.com/ONGhttps://old.scielo.br/oai/scielo-oai.php||abem-editoria@endocrino.org.br1677-94870004-2730opendoar:2007-12-17T00:00Arquivos Brasileiros de Endocrinologia & Metabologia (Online) - Sociedade Brasileira de Endocrinologia e Metabologia (SBEM)false |
dc.title.none.fl_str_mv |
Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies |
title |
Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies |
spellingShingle |
Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies Duarte,Paulo Schiavom Scintigraphy Parathyroid MIBI Sestamibi Tetrofosmin |
title_short |
Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies |
title_full |
Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies |
title_fullStr |
Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies |
title_full_unstemmed |
Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies |
title_sort |
Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies |
author |
Duarte,Paulo Schiavom |
author_facet |
Duarte,Paulo Schiavom Domingues,Fernanda C. Costa,Michele Santi Brandão,Cynthia Oliveira,Marco A.C. de Vieira,José G.H. |
author_role |
author |
author2 |
Domingues,Fernanda C. Costa,Michele Santi Brandão,Cynthia Oliveira,Marco A.C. de Vieira,José G.H. |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Duarte,Paulo Schiavom Domingues,Fernanda C. Costa,Michele Santi Brandão,Cynthia Oliveira,Marco A.C. de Vieira,José G.H. |
dc.subject.por.fl_str_mv |
Scintigraphy Parathyroid MIBI Sestamibi Tetrofosmin |
topic |
Scintigraphy Parathyroid MIBI Sestamibi Tetrofosmin |
description |
Parathyroid scintigraphies have been used to detect pathological parathyroid glands either before as well as after the parathyroid resection surgery in patients with hyperparathyroidism. One of the most utilized techniques to perform the studies is the double-phase images with Tc-99m sestamibi, which has been shown to be very accurate in the localization of enlarged parathyroid glands. Similar to Tc-99m sestamibi, Tc-99m tetrofosmin is a radiopharmaceutical initially developed to perform myocardial perfusion study that has been used to perform parathyroid scintigraphies. Although most of the papers suggest that the overall sensitivities of both radiopharmaceuticals are similar, there are some papers questioning the accuracy of Tc-99m tetrofosmin to detect abnormal parathyroid glands. In the present article, we report a case with discordant results by both methods. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/report |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
report |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27302007000700021 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27302007000700021 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0004-27302007000700021 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Endocrinologia e Metabologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Endocrinologia e Metabologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Endocrinologia & Metabologia v.51 n.7 2007 reponame:Arquivos Brasileiros de Endocrinologia & Metabologia (Online) instname:Sociedade Brasileira de Endocrinologia e Metabologia (SBEM) instacron:SBEM |
instname_str |
Sociedade Brasileira de Endocrinologia e Metabologia (SBEM) |
instacron_str |
SBEM |
institution |
SBEM |
reponame_str |
Arquivos Brasileiros de Endocrinologia & Metabologia (Online) |
collection |
Arquivos Brasileiros de Endocrinologia & Metabologia (Online) |
repository.name.fl_str_mv |
Arquivos Brasileiros de Endocrinologia & Metabologia (Online) - Sociedade Brasileira de Endocrinologia e Metabologia (SBEM) |
repository.mail.fl_str_mv |
||abem-editoria@endocrino.org.br |
_version_ |
1754734809306890240 |