Effects of plasma immersion ion implantation (PIII) of nitrogen on hardness, composition and corrosion resistance of Ti-6Al-4V alloy
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Journal of Physics |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332006000600051 |
Resumo: | Ti-6Al-4V samples have been treated by PIII processing at different temperatures (400-800 º C), treatment time (30-150 min) and plasma potential (100 and 420 V). Hardness measurements results showed an enhancement of the hardness for all implanted samples. XRD results detected the Ti2N phase and the best corrosion resistance was found for the samples processed at higher temperature and lower PIII time. |
id |
SBF-2_c8622a133c9c918042656669da703c5e |
---|---|
oai_identifier_str |
oai:scielo:S0103-97332006000600051 |
network_acronym_str |
SBF-2 |
network_name_str |
Brazilian Journal of Physics |
repository_id_str |
|
spelling |
Effects of plasma immersion ion implantation (PIII) of nitrogen on hardness, composition and corrosion resistance of Ti-6Al-4V alloyCorrosionHardnessPlasma immersion ion implantationTi-6Al-4VX-ray diffractionTi-6Al-4V samples have been treated by PIII processing at different temperatures (400-800 º C), treatment time (30-150 min) and plasma potential (100 and 420 V). Hardness measurements results showed an enhancement of the hardness for all implanted samples. XRD results detected the Ti2N phase and the best corrosion resistance was found for the samples processed at higher temperature and lower PIII time.Sociedade Brasileira de Física2006-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332006000600051Brazilian Journal of Physics v.36 n.3b 2006reponame:Brazilian Journal of Physicsinstname:Sociedade Brasileira de Física (SBF)instacron:SBF10.1590/S0103-97332006000600051info:eu-repo/semantics/openAccessSilva,Leide Lili G. daUeda,MarioSilva,Maria M. daCodaro,Eduardo N.eng2006-11-29T00:00:00Zoai:scielo:S0103-97332006000600051Revistahttp://www.sbfisica.org.br/v1/home/index.php/pt/ONGhttps://old.scielo.br/oai/scielo-oai.phpsbfisica@sbfisica.org.br||sbfisica@sbfisica.org.br1678-44480103-9733opendoar:2006-11-29T00:00Brazilian Journal of Physics - Sociedade Brasileira de Física (SBF)false |
dc.title.none.fl_str_mv |
Effects of plasma immersion ion implantation (PIII) of nitrogen on hardness, composition and corrosion resistance of Ti-6Al-4V alloy |
title |
Effects of plasma immersion ion implantation (PIII) of nitrogen on hardness, composition and corrosion resistance of Ti-6Al-4V alloy |
spellingShingle |
Effects of plasma immersion ion implantation (PIII) of nitrogen on hardness, composition and corrosion resistance of Ti-6Al-4V alloy Silva,Leide Lili G. da Corrosion Hardness Plasma immersion ion implantation Ti-6Al-4V X-ray diffraction |
title_short |
Effects of plasma immersion ion implantation (PIII) of nitrogen on hardness, composition and corrosion resistance of Ti-6Al-4V alloy |
title_full |
Effects of plasma immersion ion implantation (PIII) of nitrogen on hardness, composition and corrosion resistance of Ti-6Al-4V alloy |
title_fullStr |
Effects of plasma immersion ion implantation (PIII) of nitrogen on hardness, composition and corrosion resistance of Ti-6Al-4V alloy |
title_full_unstemmed |
Effects of plasma immersion ion implantation (PIII) of nitrogen on hardness, composition and corrosion resistance of Ti-6Al-4V alloy |
title_sort |
Effects of plasma immersion ion implantation (PIII) of nitrogen on hardness, composition and corrosion resistance of Ti-6Al-4V alloy |
author |
Silva,Leide Lili G. da |
author_facet |
Silva,Leide Lili G. da Ueda,Mario Silva,Maria M. da Codaro,Eduardo N. |
author_role |
author |
author2 |
Ueda,Mario Silva,Maria M. da Codaro,Eduardo N. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Silva,Leide Lili G. da Ueda,Mario Silva,Maria M. da Codaro,Eduardo N. |
dc.subject.por.fl_str_mv |
Corrosion Hardness Plasma immersion ion implantation Ti-6Al-4V X-ray diffraction |
topic |
Corrosion Hardness Plasma immersion ion implantation Ti-6Al-4V X-ray diffraction |
description |
Ti-6Al-4V samples have been treated by PIII processing at different temperatures (400-800 º C), treatment time (30-150 min) and plasma potential (100 and 420 V). Hardness measurements results showed an enhancement of the hardness for all implanted samples. XRD results detected the Ti2N phase and the best corrosion resistance was found for the samples processed at higher temperature and lower PIII time. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332006000600051 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332006000600051 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-97332006000600051 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Física |
publisher.none.fl_str_mv |
Sociedade Brasileira de Física |
dc.source.none.fl_str_mv |
Brazilian Journal of Physics v.36 n.3b 2006 reponame:Brazilian Journal of Physics instname:Sociedade Brasileira de Física (SBF) instacron:SBF |
instname_str |
Sociedade Brasileira de Física (SBF) |
instacron_str |
SBF |
institution |
SBF |
reponame_str |
Brazilian Journal of Physics |
collection |
Brazilian Journal of Physics |
repository.name.fl_str_mv |
Brazilian Journal of Physics - Sociedade Brasileira de Física (SBF) |
repository.mail.fl_str_mv |
sbfisica@sbfisica.org.br||sbfisica@sbfisica.org.br |
_version_ |
1754734863365177344 |