Monte Carlo simulation of a position sensitive gamma ray detector

Detalhes bibliográficos
Autor(a) principal: Almeida,Marcelo de
Data de Publicação: 2005
Outros Autores: Moralles,Maurício
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Physics
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332005000500004
Resumo: The Monte Carlo method was employed to obtain the response of a position sensitive gamma ray detector. The basic unit consists of a scintillator bar coupled to two photon detectors. Determination of the position of interaction is obtained from the ratio of the light intensity measured at each extremity of the bar. Association of two or more detectors of this type can be used to build a system with potential use in positron emission tomography. For practical purposes, a CsI(Tl) bar with dimensions of 15×1×1 \thinspacecm³ was considered. Simulations were performed with the GEANT4 toolkit, using the physical processes of low-energy electromagnetic extension. Light attenuation coefficient and energy resolution of CsI(Tl) bars were included according to data found in the literature. Results obtained from detector irradiation with 511 keV annihilation photons indicate that the position of interaction can be determined with uncertainty of 3 mm. Simulations of positron sources placed between two detectors were also performed and two dimensional images were obtained.
id SBF-2_f90499a9ae25a6c20d23019e74a5706d
oai_identifier_str oai:scielo:S0103-97332005000500004
network_acronym_str SBF-2
network_name_str Brazilian Journal of Physics
repository_id_str
spelling Monte Carlo simulation of a position sensitive gamma ray detectorThe Monte Carlo method was employed to obtain the response of a position sensitive gamma ray detector. The basic unit consists of a scintillator bar coupled to two photon detectors. Determination of the position of interaction is obtained from the ratio of the light intensity measured at each extremity of the bar. Association of two or more detectors of this type can be used to build a system with potential use in positron emission tomography. For practical purposes, a CsI(Tl) bar with dimensions of 15×1×1 \thinspacecm³ was considered. Simulations were performed with the GEANT4 toolkit, using the physical processes of low-energy electromagnetic extension. Light attenuation coefficient and energy resolution of CsI(Tl) bars were included according to data found in the literature. Results obtained from detector irradiation with 511 keV annihilation photons indicate that the position of interaction can be determined with uncertainty of 3 mm. Simulations of positron sources placed between two detectors were also performed and two dimensional images were obtained.Sociedade Brasileira de Física2005-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332005000500004Brazilian Journal of Physics v.35 n.3b 2005reponame:Brazilian Journal of Physicsinstname:Sociedade Brasileira de Física (SBF)instacron:SBF10.1590/S0103-97332005000500004info:eu-repo/semantics/openAccessAlmeida,Marcelo deMoralles,Maurícioeng2005-11-07T00:00:00Zoai:scielo:S0103-97332005000500004Revistahttp://www.sbfisica.org.br/v1/home/index.php/pt/ONGhttps://old.scielo.br/oai/scielo-oai.phpsbfisica@sbfisica.org.br||sbfisica@sbfisica.org.br1678-44480103-9733opendoar:2005-11-07T00:00Brazilian Journal of Physics - Sociedade Brasileira de Física (SBF)false
dc.title.none.fl_str_mv Monte Carlo simulation of a position sensitive gamma ray detector
title Monte Carlo simulation of a position sensitive gamma ray detector
spellingShingle Monte Carlo simulation of a position sensitive gamma ray detector
Almeida,Marcelo de
title_short Monte Carlo simulation of a position sensitive gamma ray detector
title_full Monte Carlo simulation of a position sensitive gamma ray detector
title_fullStr Monte Carlo simulation of a position sensitive gamma ray detector
title_full_unstemmed Monte Carlo simulation of a position sensitive gamma ray detector
title_sort Monte Carlo simulation of a position sensitive gamma ray detector
author Almeida,Marcelo de
author_facet Almeida,Marcelo de
Moralles,Maurício
author_role author
author2 Moralles,Maurício
author2_role author
dc.contributor.author.fl_str_mv Almeida,Marcelo de
Moralles,Maurício
description The Monte Carlo method was employed to obtain the response of a position sensitive gamma ray detector. The basic unit consists of a scintillator bar coupled to two photon detectors. Determination of the position of interaction is obtained from the ratio of the light intensity measured at each extremity of the bar. Association of two or more detectors of this type can be used to build a system with potential use in positron emission tomography. For practical purposes, a CsI(Tl) bar with dimensions of 15×1×1 \thinspacecm³ was considered. Simulations were performed with the GEANT4 toolkit, using the physical processes of low-energy electromagnetic extension. Light attenuation coefficient and energy resolution of CsI(Tl) bars were included according to data found in the literature. Results obtained from detector irradiation with 511 keV annihilation photons indicate that the position of interaction can be determined with uncertainty of 3 mm. Simulations of positron sources placed between two detectors were also performed and two dimensional images were obtained.
publishDate 2005
dc.date.none.fl_str_mv 2005-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332005000500004
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332005000500004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-97332005000500004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Física
publisher.none.fl_str_mv Sociedade Brasileira de Física
dc.source.none.fl_str_mv Brazilian Journal of Physics v.35 n.3b 2005
reponame:Brazilian Journal of Physics
instname:Sociedade Brasileira de Física (SBF)
instacron:SBF
instname_str Sociedade Brasileira de Física (SBF)
instacron_str SBF
institution SBF
reponame_str Brazilian Journal of Physics
collection Brazilian Journal of Physics
repository.name.fl_str_mv Brazilian Journal of Physics - Sociedade Brasileira de Física (SBF)
repository.mail.fl_str_mv sbfisica@sbfisica.org.br||sbfisica@sbfisica.org.br
_version_ 1754734862204403712