Comparison and analysis of agreement between different methods of measuring blood pressure in elderly
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Geriatrics, Gerontology and Aging (Online) |
Texto Completo: | https://ggaging.com/details/228 |
Resumo: | <p><b>OBJECTIVE:</b> Compare and verify the agreement of measurements of blood pressure systolic (SBP) and diastolic (DBP) obtained by auscultatory methods (mercury column) and oscillometric (Omron - 412C), in elderly women.<br> <b>METHODS:</b> Three blood pressure (BP) measurements by two minutes intervals were measured from 47 elderly (66.8 ± 5.3 years). The oscillometric device was connected in "Y" with the mercury sphygmomanometer and the SBP and DBP values were recorded by two evaluators "blinded".<br> <b>RESULTS:</b> For each device, significant differences were not observed (P < 0.01) between measurements (1, 2 and 3) SBP and DBP Except for the second measure of PAD, statistically significant differences (P > 0.01) were identified from the mean SBP and DBP, estimated by different methods. Although significant positive correlations (P < 0.01) e high magnitude were identified between the two methods investigated for SBD (r = 0.891) and DBP (r = 0.813), concordance analysis indicated relatively large limits. The SBP was underestimated by up to 23.1 mmHg or overestimated of up to 12.8 mmHg and in DBP was underestimated by up to 13.4 mmHg or overestimates of up to 9.0 mmHg for oscillometric method in the face of auscultation.<br> <b>CONCLUSION:</b> The results of this study suggest that SBP and DBP appear to be influenced by using different methods of evaluating BP</p> |
id |
SBGG_bf20fb4a30a6182e76cefe584d2529e9 |
---|---|
oai_identifier_str |
oai:ggaging.com:228 |
network_acronym_str |
SBGG |
network_name_str |
Geriatrics, Gerontology and Aging (Online) |
repository_id_str |
|
spelling |
Comparison and analysis of agreement between different methods of measuring blood pressure in elderlyOscillometric device, sphygmomanometer, aging, blood pressure monitor.<p><b>OBJECTIVE:</b> Compare and verify the agreement of measurements of blood pressure systolic (SBP) and diastolic (DBP) obtained by auscultatory methods (mercury column) and oscillometric (Omron - 412C), in elderly women.<br> <b>METHODS:</b> Three blood pressure (BP) measurements by two minutes intervals were measured from 47 elderly (66.8 ± 5.3 years). The oscillometric device was connected in "Y" with the mercury sphygmomanometer and the SBP and DBP values were recorded by two evaluators "blinded".<br> <b>RESULTS:</b> For each device, significant differences were not observed (P < 0.01) between measurements (1, 2 and 3) SBP and DBP Except for the second measure of PAD, statistically significant differences (P > 0.01) were identified from the mean SBP and DBP, estimated by different methods. Although significant positive correlations (P < 0.01) e high magnitude were identified between the two methods investigated for SBD (r = 0.891) and DBP (r = 0.813), concordance analysis indicated relatively large limits. The SBP was underestimated by up to 23.1 mmHg or overestimated of up to 12.8 mmHg and in DBP was underestimated by up to 13.4 mmHg or overestimates of up to 9.0 mmHg for oscillometric method in the face of auscultation.<br> <b>CONCLUSION:</b> The results of this study suggest that SBP and DBP appear to be influenced by using different methods of evaluating BP</p>Sociedade Brasileira de Geriatria e Gerontologia2011-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttps://ggaging.com/details/228Geriatrics, Gerontology and Aging v.5 n.4 2011reponame:Geriatrics, Gerontology and Aging (Online)instname:Sociedade Brasileira de Geriatria e Gerontologiainstacron:SBGGinfo:eu-repo/semantics/openAccess Oliveira,Gislene Cristine Franco de Filho,José Claudio Jambassi Gurjão,André Luiz De-mantova Ceccato,Marilia Zuzzi,Denise Cristina Gobbi,Sebastiãoeng2011-10-01T00:00:00Zoai:ggaging.com:228Revistahttp://sbgg.org.br/publicacoes-cientificas/revista-geriatria-gerontologia/ONGhttps://old.scielo.br/oai/scielo-oai.phpexecutiveditors@ggaging.com||nacional@sbgg.org.br2447-21232447-2115opendoar:2011-10-01T00:00Geriatrics, Gerontology and Aging (Online) - Sociedade Brasileira de Geriatria e Gerontologiafalse |
dc.title.none.fl_str_mv |
Comparison and analysis of agreement between different methods of measuring blood pressure in elderly |
title |
Comparison and analysis of agreement between different methods of measuring blood pressure in elderly |
spellingShingle |
Comparison and analysis of agreement between different methods of measuring blood pressure in elderly Oliveira,Gislene Cristine Franco de Oscillometric device, sphygmomanometer, aging, blood pressure monitor. |
title_short |
Comparison and analysis of agreement between different methods of measuring blood pressure in elderly |
title_full |
Comparison and analysis of agreement between different methods of measuring blood pressure in elderly |
title_fullStr |
Comparison and analysis of agreement between different methods of measuring blood pressure in elderly |
title_full_unstemmed |
Comparison and analysis of agreement between different methods of measuring blood pressure in elderly |
title_sort |
Comparison and analysis of agreement between different methods of measuring blood pressure in elderly |
author |
Oliveira,Gislene Cristine Franco de |
author_facet |
Oliveira,Gislene Cristine Franco de Filho,José Claudio Jambassi Gurjão,André Luiz De-mantova Ceccato,Marilia Zuzzi,Denise Cristina Gobbi,Sebastião |
author_role |
author |
author2 |
Filho,José Claudio Jambassi Gurjão,André Luiz De-mantova Ceccato,Marilia Zuzzi,Denise Cristina Gobbi,Sebastião |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Oliveira,Gislene Cristine Franco de Filho,José Claudio Jambassi Gurjão,André Luiz De-mantova Ceccato,Marilia Zuzzi,Denise Cristina Gobbi,Sebastião |
dc.subject.por.fl_str_mv |
Oscillometric device, sphygmomanometer, aging, blood pressure monitor. |
topic |
Oscillometric device, sphygmomanometer, aging, blood pressure monitor. |
description |
<p><b>OBJECTIVE:</b> Compare and verify the agreement of measurements of blood pressure systolic (SBP) and diastolic (DBP) obtained by auscultatory methods (mercury column) and oscillometric (Omron - 412C), in elderly women.<br> <b>METHODS:</b> Three blood pressure (BP) measurements by two minutes intervals were measured from 47 elderly (66.8 ± 5.3 years). The oscillometric device was connected in "Y" with the mercury sphygmomanometer and the SBP and DBP values were recorded by two evaluators "blinded".<br> <b>RESULTS:</b> For each device, significant differences were not observed (P < 0.01) between measurements (1, 2 and 3) SBP and DBP Except for the second measure of PAD, statistically significant differences (P > 0.01) were identified from the mean SBP and DBP, estimated by different methods. Although significant positive correlations (P < 0.01) e high magnitude were identified between the two methods investigated for SBD (r = 0.891) and DBP (r = 0.813), concordance analysis indicated relatively large limits. The SBP was underestimated by up to 23.1 mmHg or overestimated of up to 12.8 mmHg and in DBP was underestimated by up to 13.4 mmHg or overestimates of up to 9.0 mmHg for oscillometric method in the face of auscultation.<br> <b>CONCLUSION:</b> The results of this study suggest that SBP and DBP appear to be influenced by using different methods of evaluating BP</p> |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://ggaging.com/details/228 |
url |
https://ggaging.com/details/228 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Geriatria e Gerontologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Geriatria e Gerontologia |
dc.source.none.fl_str_mv |
Geriatrics, Gerontology and Aging v.5 n.4 2011 reponame:Geriatrics, Gerontology and Aging (Online) instname:Sociedade Brasileira de Geriatria e Gerontologia instacron:SBGG |
instname_str |
Sociedade Brasileira de Geriatria e Gerontologia |
instacron_str |
SBGG |
institution |
SBGG |
reponame_str |
Geriatrics, Gerontology and Aging (Online) |
collection |
Geriatrics, Gerontology and Aging (Online) |
repository.name.fl_str_mv |
Geriatrics, Gerontology and Aging (Online) - Sociedade Brasileira de Geriatria e Gerontologia |
repository.mail.fl_str_mv |
executiveditors@ggaging.com||nacional@sbgg.org.br |
_version_ |
1797174501282152448 |