Evaluation of the PetrifilmTM EB and TEMPO® EB systems with ISO 21528-2:2004 method for the count of Enterobacteriaceae in milk

Detalhes bibliográficos
Autor(a) principal: Cirolini,Andréia
Data de Publicação: 2013
Outros Autores: Miotto,Marília, Machado,Fernanda Morgana, Silva,Helen Silvestre da, Ogliari,Paulo José, Vieira,Cleide Rosana Werneck
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Microbiology
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-83822013000300016
Resumo: The development of alternative microbiological techniques is driven by the necessity to meet the current needs to deliver rapid results in the manufacturing process of foods, but it is important that these methods be evaluated for each application. The objective of the present study was to assess the PetrifilmTM EB and the TEMPO® EB systems with ISO 21528-2:2004 for the count of Enterobacteriaceae in pasteurized and UHT milk samples. We analyzed the microflora of 141 pasteurized milk samples, 15 samples of artificially contaminated pasteurized milk and 15 samples of artificially contaminated UHT milk. Investigation of the method PetrifilmTM EB and ISO 21528:2 regression analysis showed a high correlation in the samples, r = 0.90 for the microflora of pasteurized milk, r = 0.98 for artificially contaminated pasteurized milk and r = 0.99 for the artificially contaminated UHT milk. In evaluating the system TEMPO EB ® method and ISO 21528:2 correlation was also significant in the analyzed samples, with r = 0.86 for the microflora of pasteurized milk, r = 0.96 for artificially contaminated pasteurized milk and r = 0.99 for artificially contaminated UHT milk. No statistically significant differences were observed between the three methods conducted to analyze artificially contaminated pasteurized and UHT milk at three inoculum levels. In conclusion, the PetrifilmTM EB system and the TEMPO® EB system may be an alternative to the ISO 21528-2:2004 for the Enterobacteriaceae assay for milk as because of the ease-of-operation and the time reduction achieved for conducting the microbiological assay using these systems.
id SBM-1_a9020aa20f533c457ecc0811e857a23a
oai_identifier_str oai:scielo:S1517-83822013000300016
network_acronym_str SBM-1
network_name_str Brazilian Journal of Microbiology
repository_id_str
spelling Evaluation of the PetrifilmTM EB and TEMPO® EB systems with ISO 21528-2:2004 method for the count of Enterobacteriaceae in milkEnterobacteriaceaemilkalternative methodsISO 21528-2:2004countThe development of alternative microbiological techniques is driven by the necessity to meet the current needs to deliver rapid results in the manufacturing process of foods, but it is important that these methods be evaluated for each application. The objective of the present study was to assess the PetrifilmTM EB and the TEMPO® EB systems with ISO 21528-2:2004 for the count of Enterobacteriaceae in pasteurized and UHT milk samples. We analyzed the microflora of 141 pasteurized milk samples, 15 samples of artificially contaminated pasteurized milk and 15 samples of artificially contaminated UHT milk. Investigation of the method PetrifilmTM EB and ISO 21528:2 regression analysis showed a high correlation in the samples, r = 0.90 for the microflora of pasteurized milk, r = 0.98 for artificially contaminated pasteurized milk and r = 0.99 for the artificially contaminated UHT milk. In evaluating the system TEMPO EB ® method and ISO 21528:2 correlation was also significant in the analyzed samples, with r = 0.86 for the microflora of pasteurized milk, r = 0.96 for artificially contaminated pasteurized milk and r = 0.99 for artificially contaminated UHT milk. No statistically significant differences were observed between the three methods conducted to analyze artificially contaminated pasteurized and UHT milk at three inoculum levels. In conclusion, the PetrifilmTM EB system and the TEMPO® EB system may be an alternative to the ISO 21528-2:2004 for the Enterobacteriaceae assay for milk as because of the ease-of-operation and the time reduction achieved for conducting the microbiological assay using these systems.Sociedade Brasileira de Microbiologia2013-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-83822013000300016Brazilian Journal of Microbiology v.44 n.3 2013reponame:Brazilian Journal of Microbiologyinstname:Sociedade Brasileira de Microbiologia (SBM)instacron:SBM10.1590/S1517-83822013000300016info:eu-repo/semantics/openAccessCirolini,AndréiaMiotto,MaríliaMachado,Fernanda MorganaSilva,Helen Silvestre daOgliari,Paulo JoséVieira,Cleide Rosana Werneckeng2014-02-03T00:00:00Zoai:scielo:S1517-83822013000300016Revistahttps://www.scielo.br/j/bjm/ONGhttps://old.scielo.br/oai/scielo-oai.phpbjm@sbmicrobiologia.org.br||mbmartin@usp.br1678-44051517-8382opendoar:2014-02-03T00:00Brazilian Journal of Microbiology - Sociedade Brasileira de Microbiologia (SBM)false
dc.title.none.fl_str_mv Evaluation of the PetrifilmTM EB and TEMPO® EB systems with ISO 21528-2:2004 method for the count of Enterobacteriaceae in milk
title Evaluation of the PetrifilmTM EB and TEMPO® EB systems with ISO 21528-2:2004 method for the count of Enterobacteriaceae in milk
spellingShingle Evaluation of the PetrifilmTM EB and TEMPO® EB systems with ISO 21528-2:2004 method for the count of Enterobacteriaceae in milk
Cirolini,Andréia
Enterobacteriaceae
milk
alternative methods
ISO 21528-2:2004
count
title_short Evaluation of the PetrifilmTM EB and TEMPO® EB systems with ISO 21528-2:2004 method for the count of Enterobacteriaceae in milk
title_full Evaluation of the PetrifilmTM EB and TEMPO® EB systems with ISO 21528-2:2004 method for the count of Enterobacteriaceae in milk
title_fullStr Evaluation of the PetrifilmTM EB and TEMPO® EB systems with ISO 21528-2:2004 method for the count of Enterobacteriaceae in milk
title_full_unstemmed Evaluation of the PetrifilmTM EB and TEMPO® EB systems with ISO 21528-2:2004 method for the count of Enterobacteriaceae in milk
title_sort Evaluation of the PetrifilmTM EB and TEMPO® EB systems with ISO 21528-2:2004 method for the count of Enterobacteriaceae in milk
author Cirolini,Andréia
author_facet Cirolini,Andréia
Miotto,Marília
Machado,Fernanda Morgana
Silva,Helen Silvestre da
Ogliari,Paulo José
Vieira,Cleide Rosana Werneck
author_role author
author2 Miotto,Marília
Machado,Fernanda Morgana
Silva,Helen Silvestre da
Ogliari,Paulo José
Vieira,Cleide Rosana Werneck
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Cirolini,Andréia
Miotto,Marília
Machado,Fernanda Morgana
Silva,Helen Silvestre da
Ogliari,Paulo José
Vieira,Cleide Rosana Werneck
dc.subject.por.fl_str_mv Enterobacteriaceae
milk
alternative methods
ISO 21528-2:2004
count
topic Enterobacteriaceae
milk
alternative methods
ISO 21528-2:2004
count
description The development of alternative microbiological techniques is driven by the necessity to meet the current needs to deliver rapid results in the manufacturing process of foods, but it is important that these methods be evaluated for each application. The objective of the present study was to assess the PetrifilmTM EB and the TEMPO® EB systems with ISO 21528-2:2004 for the count of Enterobacteriaceae in pasteurized and UHT milk samples. We analyzed the microflora of 141 pasteurized milk samples, 15 samples of artificially contaminated pasteurized milk and 15 samples of artificially contaminated UHT milk. Investigation of the method PetrifilmTM EB and ISO 21528:2 regression analysis showed a high correlation in the samples, r = 0.90 for the microflora of pasteurized milk, r = 0.98 for artificially contaminated pasteurized milk and r = 0.99 for the artificially contaminated UHT milk. In evaluating the system TEMPO EB ® method and ISO 21528:2 correlation was also significant in the analyzed samples, with r = 0.86 for the microflora of pasteurized milk, r = 0.96 for artificially contaminated pasteurized milk and r = 0.99 for artificially contaminated UHT milk. No statistically significant differences were observed between the three methods conducted to analyze artificially contaminated pasteurized and UHT milk at three inoculum levels. In conclusion, the PetrifilmTM EB system and the TEMPO® EB system may be an alternative to the ISO 21528-2:2004 for the Enterobacteriaceae assay for milk as because of the ease-of-operation and the time reduction achieved for conducting the microbiological assay using these systems.
publishDate 2013
dc.date.none.fl_str_mv 2013-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-83822013000300016
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1517-83822013000300016
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1517-83822013000300016
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Microbiologia
publisher.none.fl_str_mv Sociedade Brasileira de Microbiologia
dc.source.none.fl_str_mv Brazilian Journal of Microbiology v.44 n.3 2013
reponame:Brazilian Journal of Microbiology
instname:Sociedade Brasileira de Microbiologia (SBM)
instacron:SBM
instname_str Sociedade Brasileira de Microbiologia (SBM)
instacron_str SBM
institution SBM
reponame_str Brazilian Journal of Microbiology
collection Brazilian Journal of Microbiology
repository.name.fl_str_mv Brazilian Journal of Microbiology - Sociedade Brasileira de Microbiologia (SBM)
repository.mail.fl_str_mv bjm@sbmicrobiologia.org.br||mbmartin@usp.br
_version_ 1752122205558276096