A modified banding technique: experience of a center

Detalhes bibliográficos
Autor(a) principal: Cerqueira,Sofia S. G.
Data de Publicação: 2021
Outros Autores: Ferreira,Joana M., Fructuoso,Mónica R., Eusebio,Catarina, Castro,Rui A., Morgado,Teresa M.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Jornal Brasileiro de Nefrologia
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-28002021000100041
Resumo: ABSTRACT Background: A well-functioning vascular access is vital to patients on regular hemodialysis. Banding the access is indicated in high-flow-associated steal syndrome. It allows for the reduction of access flow while maintaining distal limb perfusion. Nonetheless, this procedure has some limitations as it can cause hemorrhage, infection, aneurysm formation, thrombosis of access in cases of overbanding, or otherwise insufficient reduction of vascular flow. Other surgical techniques to achieve the same benefit would be useful. Methods: We performed a modified banding technique without endovascular placement of the angioplasty balloon, which is a viable alternative to other techniques. This surgery was performed in patients on chronic dialysis with steal syndrome. Pre- and post-operative access flows were measured and resolution of symptoms was recorded. Primary patency rate was defined as the intervention-free access survival from the operative time. Results: We verified that this technique allowed for access flow reduction in all our six patients, with total resolution of symptoms in all patients. Primary patency rate at 12 months was 100%. No major complications were noted during our follow-up. Conclusions: This technique allows for correction of high-flow arteriovenous fistulas in an efficient and safe way, and can be a viable alternative to other banding procedures.
id SBN-1_111205f01b60137ec86e9cb72276a243
oai_identifier_str oai:scielo:S0101-28002021000100041
network_acronym_str SBN-1
network_name_str Jornal Brasileiro de Nefrologia
repository_id_str
spelling A modified banding technique: experience of a centerRenal DialysisArteriovenous FistulaAthletic TapeABSTRACT Background: A well-functioning vascular access is vital to patients on regular hemodialysis. Banding the access is indicated in high-flow-associated steal syndrome. It allows for the reduction of access flow while maintaining distal limb perfusion. Nonetheless, this procedure has some limitations as it can cause hemorrhage, infection, aneurysm formation, thrombosis of access in cases of overbanding, or otherwise insufficient reduction of vascular flow. Other surgical techniques to achieve the same benefit would be useful. Methods: We performed a modified banding technique without endovascular placement of the angioplasty balloon, which is a viable alternative to other techniques. This surgery was performed in patients on chronic dialysis with steal syndrome. Pre- and post-operative access flows were measured and resolution of symptoms was recorded. Primary patency rate was defined as the intervention-free access survival from the operative time. Results: We verified that this technique allowed for access flow reduction in all our six patients, with total resolution of symptoms in all patients. Primary patency rate at 12 months was 100%. No major complications were noted during our follow-up. Conclusions: This technique allows for correction of high-flow arteriovenous fistulas in an efficient and safe way, and can be a viable alternative to other banding procedures.Sociedade Brasileira de Nefrologia2021-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-28002021000100041Brazilian Journal of Nephrology v.43 n.1 2021reponame:Jornal Brasileiro de Nefrologiainstname:Sociedade Brasileira de Nefrologia (SBN)instacron:SBN10.1590/2175-8239-jbn-2020-0046info:eu-repo/semantics/openAccessCerqueira,Sofia S. G.Ferreira,Joana M.Fructuoso,Mónica R.Eusebio,CatarinaCastro,Rui A.Morgado,Teresa M.eng2021-05-10T00:00:00Zoai:scielo:S0101-28002021000100041Revistahttp://www.bjn.org.br/ONGhttps://old.scielo.br/oai/scielo-oai.php||jbn@sbn.org.br2175-82390101-2800opendoar:2021-05-10T00:00Jornal Brasileiro de Nefrologia - Sociedade Brasileira de Nefrologia (SBN)false
dc.title.none.fl_str_mv A modified banding technique: experience of a center
title A modified banding technique: experience of a center
spellingShingle A modified banding technique: experience of a center
Cerqueira,Sofia S. G.
Renal Dialysis
Arteriovenous Fistula
Athletic Tape
title_short A modified banding technique: experience of a center
title_full A modified banding technique: experience of a center
title_fullStr A modified banding technique: experience of a center
title_full_unstemmed A modified banding technique: experience of a center
title_sort A modified banding technique: experience of a center
author Cerqueira,Sofia S. G.
author_facet Cerqueira,Sofia S. G.
Ferreira,Joana M.
Fructuoso,Mónica R.
Eusebio,Catarina
Castro,Rui A.
Morgado,Teresa M.
author_role author
author2 Ferreira,Joana M.
Fructuoso,Mónica R.
Eusebio,Catarina
Castro,Rui A.
Morgado,Teresa M.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Cerqueira,Sofia S. G.
Ferreira,Joana M.
Fructuoso,Mónica R.
Eusebio,Catarina
Castro,Rui A.
Morgado,Teresa M.
dc.subject.por.fl_str_mv Renal Dialysis
Arteriovenous Fistula
Athletic Tape
topic Renal Dialysis
Arteriovenous Fistula
Athletic Tape
description ABSTRACT Background: A well-functioning vascular access is vital to patients on regular hemodialysis. Banding the access is indicated in high-flow-associated steal syndrome. It allows for the reduction of access flow while maintaining distal limb perfusion. Nonetheless, this procedure has some limitations as it can cause hemorrhage, infection, aneurysm formation, thrombosis of access in cases of overbanding, or otherwise insufficient reduction of vascular flow. Other surgical techniques to achieve the same benefit would be useful. Methods: We performed a modified banding technique without endovascular placement of the angioplasty balloon, which is a viable alternative to other techniques. This surgery was performed in patients on chronic dialysis with steal syndrome. Pre- and post-operative access flows were measured and resolution of symptoms was recorded. Primary patency rate was defined as the intervention-free access survival from the operative time. Results: We verified that this technique allowed for access flow reduction in all our six patients, with total resolution of symptoms in all patients. Primary patency rate at 12 months was 100%. No major complications were noted during our follow-up. Conclusions: This technique allows for correction of high-flow arteriovenous fistulas in an efficient and safe way, and can be a viable alternative to other banding procedures.
publishDate 2021
dc.date.none.fl_str_mv 2021-03-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-28002021000100041
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-28002021000100041
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/2175-8239-jbn-2020-0046
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Nefrologia
publisher.none.fl_str_mv Sociedade Brasileira de Nefrologia
dc.source.none.fl_str_mv Brazilian Journal of Nephrology v.43 n.1 2021
reponame:Jornal Brasileiro de Nefrologia
instname:Sociedade Brasileira de Nefrologia (SBN)
instacron:SBN
instname_str Sociedade Brasileira de Nefrologia (SBN)
instacron_str SBN
institution SBN
reponame_str Jornal Brasileiro de Nefrologia
collection Jornal Brasileiro de Nefrologia
repository.name.fl_str_mv Jornal Brasileiro de Nefrologia - Sociedade Brasileira de Nefrologia (SBN)
repository.mail.fl_str_mv ||jbn@sbn.org.br
_version_ 1752122066517098496