Sealing the gap between conjunctiva and Tenon’s capsule in primary pterygium surgery
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802014000500287 |
Resumo: | Objetive: To assess the results of an alternative surgical approach in the excision of primary pterygium by analyzing the rates of recurrence and of intraoperative and postoperative complications. Methods: Retrospective cross-sectional study based reviewing the clinical records of individuals subjected to surgery for pterygium, with conjunctival autograft transplantation, fibrin glue and intraoperative application of mitomycin C. In addition, sealing was performed by suturing the gap between the conjunctiva and Tenon’s capsule. A total of 36 eyes from 35 individuals were subjected to the assessed techniques. The study variables were complications of surgery and recurrence rates during a minimun follow-up period of 6 months. Results: No recurrence occurred during the follow-up period. One graft (2.8%) exhibited partial retraction, but pterygium did not recur. The intraocular pressure increased in one eye (2.8%) and was controlled by clinical methods. Conclusion: Eyes in which a barrier was established between the conjunctiva and Tenon’s capsule by sealing the gap between them showed an absence of recurrence in the sample studied. However, there is the need of a random prospective study with a control group for a more accurate conclusion on the efficacy of the technique |
id |
SBO-1_6f4dce5a3971d6aa662fc392fe45a441 |
---|---|
oai_identifier_str |
oai:scielo:S0034-72802014000500287 |
network_acronym_str |
SBO-1 |
network_name_str |
Revista Brasileira de Oftalmologia (Online) |
repository_id_str |
|
spelling |
Sealing the gap between conjunctiva and Tenon’s capsule in primary pterygium surgeryPterygium/surgeryAutograftsTransplantation, autologousMitomycin/therapeutic useFibrin tissue adhesiveRecurrence Objetive: To assess the results of an alternative surgical approach in the excision of primary pterygium by analyzing the rates of recurrence and of intraoperative and postoperative complications. Methods: Retrospective cross-sectional study based reviewing the clinical records of individuals subjected to surgery for pterygium, with conjunctival autograft transplantation, fibrin glue and intraoperative application of mitomycin C. In addition, sealing was performed by suturing the gap between the conjunctiva and Tenon’s capsule. A total of 36 eyes from 35 individuals were subjected to the assessed techniques. The study variables were complications of surgery and recurrence rates during a minimun follow-up period of 6 months. Results: No recurrence occurred during the follow-up period. One graft (2.8%) exhibited partial retraction, but pterygium did not recur. The intraocular pressure increased in one eye (2.8%) and was controlled by clinical methods. Conclusion: Eyes in which a barrier was established between the conjunctiva and Tenon’s capsule by sealing the gap between them showed an absence of recurrence in the sample studied. However, there is the need of a random prospective study with a control group for a more accurate conclusion on the efficacy of the technique Sociedade Brasileira de Oftalmologia2014-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802014000500287Revista Brasileira de Oftalmologia v.73 n.5 2014reponame:Revista Brasileira de Oftalmologia (Online)instname:Sociedade Brasileira de Oftalmologia (SBO)instacron:SBO10.5935/0034-7280.20140062info:eu-repo/semantics/openAccessStock,Ricardo AlexandreLückmann,Luan FelipeKondo,Gabriel Alexander Ken-ItchiBonamigo,Elcio Luizeng2015-02-13T00:00:00Zoai:scielo:S0034-72802014000500287Revistahttps://rbo.emnuvens.com.br/rbo/indexhttps://old.scielo.br/oai/scielo-oai.phpsob@sboportal.org.br||rbo@sboportal.org.br1982-85510034-7280opendoar:2015-02-13T00:00Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)false |
dc.title.none.fl_str_mv |
Sealing the gap between conjunctiva and Tenon’s capsule in primary pterygium surgery |
title |
Sealing the gap between conjunctiva and Tenon’s capsule in primary pterygium surgery |
spellingShingle |
Sealing the gap between conjunctiva and Tenon’s capsule in primary pterygium surgery Stock,Ricardo Alexandre Pterygium/surgery Autografts Transplantation, autologous Mitomycin/therapeutic use Fibrin tissue adhesive Recurrence |
title_short |
Sealing the gap between conjunctiva and Tenon’s capsule in primary pterygium surgery |
title_full |
Sealing the gap between conjunctiva and Tenon’s capsule in primary pterygium surgery |
title_fullStr |
Sealing the gap between conjunctiva and Tenon’s capsule in primary pterygium surgery |
title_full_unstemmed |
Sealing the gap between conjunctiva and Tenon’s capsule in primary pterygium surgery |
title_sort |
Sealing the gap between conjunctiva and Tenon’s capsule in primary pterygium surgery |
author |
Stock,Ricardo Alexandre |
author_facet |
Stock,Ricardo Alexandre Lückmann,Luan Felipe Kondo,Gabriel Alexander Ken-Itchi Bonamigo,Elcio Luiz |
author_role |
author |
author2 |
Lückmann,Luan Felipe Kondo,Gabriel Alexander Ken-Itchi Bonamigo,Elcio Luiz |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Stock,Ricardo Alexandre Lückmann,Luan Felipe Kondo,Gabriel Alexander Ken-Itchi Bonamigo,Elcio Luiz |
dc.subject.por.fl_str_mv |
Pterygium/surgery Autografts Transplantation, autologous Mitomycin/therapeutic use Fibrin tissue adhesive Recurrence |
topic |
Pterygium/surgery Autografts Transplantation, autologous Mitomycin/therapeutic use Fibrin tissue adhesive Recurrence |
description |
Objetive: To assess the results of an alternative surgical approach in the excision of primary pterygium by analyzing the rates of recurrence and of intraoperative and postoperative complications. Methods: Retrospective cross-sectional study based reviewing the clinical records of individuals subjected to surgery for pterygium, with conjunctival autograft transplantation, fibrin glue and intraoperative application of mitomycin C. In addition, sealing was performed by suturing the gap between the conjunctiva and Tenon’s capsule. A total of 36 eyes from 35 individuals were subjected to the assessed techniques. The study variables were complications of surgery and recurrence rates during a minimun follow-up period of 6 months. Results: No recurrence occurred during the follow-up period. One graft (2.8%) exhibited partial retraction, but pterygium did not recur. The intraocular pressure increased in one eye (2.8%) and was controlled by clinical methods. Conclusion: Eyes in which a barrier was established between the conjunctiva and Tenon’s capsule by sealing the gap between them showed an absence of recurrence in the sample studied. However, there is the need of a random prospective study with a control group for a more accurate conclusion on the efficacy of the technique |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802014000500287 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802014000500287 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0034-7280.20140062 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Oftalmologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Oftalmologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Oftalmologia v.73 n.5 2014 reponame:Revista Brasileira de Oftalmologia (Online) instname:Sociedade Brasileira de Oftalmologia (SBO) instacron:SBO |
instname_str |
Sociedade Brasileira de Oftalmologia (SBO) |
instacron_str |
SBO |
institution |
SBO |
reponame_str |
Revista Brasileira de Oftalmologia (Online) |
collection |
Revista Brasileira de Oftalmologia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO) |
repository.mail.fl_str_mv |
sob@sboportal.org.br||rbo@sboportal.org.br |
_version_ |
1752122337001472000 |