Digital asthenopia: blue-blocking lenses and + 0,40D additional power in the near zone, for eye strain, accommodation and convergence functions
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802022000100225 |
Resumo: | ABSTRACT Purpose Evaluate blue-violet light filter and additional power of +0.40 D in the near zone ophthalmic lenses, on convergence, accommodative functions, and symptoms of digital asthenopia (DA). Methods Randomized study in cross-over design conducted on 49 volunteers (age, 29 ± 5.5 years; male: female, 18:31). Each subject wore test (+0.40 D in the near zone) and control lenses (regular single vision) for 4 weeks in randomized order. Both lenses had a selective blue-violet light filter. A baseline measurement was taken with the subjects’ current updated glasses. Accommodation amplitude (AA) and near point of convergence (NPC) were measured binocularly with the RAF ruler. DA was evaluated by a questionnaire. Results No significant difference (p=.52) was found for AA comparing baseline (11.50±1.88 D), test (11.61± 1.62 D), and control SV lenses (11.88±1.50 D). No significant difference was found for NPC (p=.94), between baseline (6.50 ± 2.89cm), test (6.71± 3.49) and control SV lenses (6.82± 3.50 cm). No significant difference was found comparing test and control SV lenses in symptoms of DA (p=0.20). Conclusions The +0.40 D lenses have no negative impact on convergence or loss of accommodation power. The +0.40 D and control SV lenses had a similar impact on attenuating symptoms of DA. |
id |
SBO-1_d0e408f62393e7eb6dd2f733592cfe7a |
---|---|
oai_identifier_str |
oai:scielo:S0034-72802022000100225 |
network_acronym_str |
SBO-1 |
network_name_str |
Revista Brasileira de Oftalmologia (Online) |
repository_id_str |
|
spelling |
Digital asthenopia: blue-blocking lenses and + 0,40D additional power in the near zone, for eye strain, accommodation and convergence functionsAsthenopiaDry eye syndromesLightingSmartphoneABSTRACT Purpose Evaluate blue-violet light filter and additional power of +0.40 D in the near zone ophthalmic lenses, on convergence, accommodative functions, and symptoms of digital asthenopia (DA). Methods Randomized study in cross-over design conducted on 49 volunteers (age, 29 ± 5.5 years; male: female, 18:31). Each subject wore test (+0.40 D in the near zone) and control lenses (regular single vision) for 4 weeks in randomized order. Both lenses had a selective blue-violet light filter. A baseline measurement was taken with the subjects’ current updated glasses. Accommodation amplitude (AA) and near point of convergence (NPC) were measured binocularly with the RAF ruler. DA was evaluated by a questionnaire. Results No significant difference (p=.52) was found for AA comparing baseline (11.50±1.88 D), test (11.61± 1.62 D), and control SV lenses (11.88±1.50 D). No significant difference was found for NPC (p=.94), between baseline (6.50 ± 2.89cm), test (6.71± 3.49) and control SV lenses (6.82± 3.50 cm). No significant difference was found comparing test and control SV lenses in symptoms of DA (p=0.20). Conclusions The +0.40 D lenses have no negative impact on convergence or loss of accommodation power. The +0.40 D and control SV lenses had a similar impact on attenuating symptoms of DA.Sociedade Brasileira de Oftalmologia2022-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802022000100225Revista Brasileira de Oftalmologia v.81 2022reponame:Revista Brasileira de Oftalmologia (Online)instname:Sociedade Brasileira de Oftalmologia (SBO)instacron:SBO10.37039/1982.8551.20220054info:eu-repo/semantics/openAccessAlionis,Aline Cristina Fioravanti LuiNetto,Adamo LuiLui,Tatiana Adarli FioravantiAlves,Milton Ruizeng2022-07-25T00:00:00Zoai:scielo:S0034-72802022000100225Revistahttps://rbo.emnuvens.com.br/rbo/indexhttps://old.scielo.br/oai/scielo-oai.phpsob@sboportal.org.br||rbo@sboportal.org.br1982-85510034-7280opendoar:2022-07-25T00:00Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)false |
dc.title.none.fl_str_mv |
Digital asthenopia: blue-blocking lenses and + 0,40D additional power in the near zone, for eye strain, accommodation and convergence functions |
title |
Digital asthenopia: blue-blocking lenses and + 0,40D additional power in the near zone, for eye strain, accommodation and convergence functions |
spellingShingle |
Digital asthenopia: blue-blocking lenses and + 0,40D additional power in the near zone, for eye strain, accommodation and convergence functions Alionis,Aline Cristina Fioravanti Lui Asthenopia Dry eye syndromes Lighting Smartphone |
title_short |
Digital asthenopia: blue-blocking lenses and + 0,40D additional power in the near zone, for eye strain, accommodation and convergence functions |
title_full |
Digital asthenopia: blue-blocking lenses and + 0,40D additional power in the near zone, for eye strain, accommodation and convergence functions |
title_fullStr |
Digital asthenopia: blue-blocking lenses and + 0,40D additional power in the near zone, for eye strain, accommodation and convergence functions |
title_full_unstemmed |
Digital asthenopia: blue-blocking lenses and + 0,40D additional power in the near zone, for eye strain, accommodation and convergence functions |
title_sort |
Digital asthenopia: blue-blocking lenses and + 0,40D additional power in the near zone, for eye strain, accommodation and convergence functions |
author |
Alionis,Aline Cristina Fioravanti Lui |
author_facet |
Alionis,Aline Cristina Fioravanti Lui Netto,Adamo Lui Lui,Tatiana Adarli Fioravanti Alves,Milton Ruiz |
author_role |
author |
author2 |
Netto,Adamo Lui Lui,Tatiana Adarli Fioravanti Alves,Milton Ruiz |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Alionis,Aline Cristina Fioravanti Lui Netto,Adamo Lui Lui,Tatiana Adarli Fioravanti Alves,Milton Ruiz |
dc.subject.por.fl_str_mv |
Asthenopia Dry eye syndromes Lighting Smartphone |
topic |
Asthenopia Dry eye syndromes Lighting Smartphone |
description |
ABSTRACT Purpose Evaluate blue-violet light filter and additional power of +0.40 D in the near zone ophthalmic lenses, on convergence, accommodative functions, and symptoms of digital asthenopia (DA). Methods Randomized study in cross-over design conducted on 49 volunteers (age, 29 ± 5.5 years; male: female, 18:31). Each subject wore test (+0.40 D in the near zone) and control lenses (regular single vision) for 4 weeks in randomized order. Both lenses had a selective blue-violet light filter. A baseline measurement was taken with the subjects’ current updated glasses. Accommodation amplitude (AA) and near point of convergence (NPC) were measured binocularly with the RAF ruler. DA was evaluated by a questionnaire. Results No significant difference (p=.52) was found for AA comparing baseline (11.50±1.88 D), test (11.61± 1.62 D), and control SV lenses (11.88±1.50 D). No significant difference was found for NPC (p=.94), between baseline (6.50 ± 2.89cm), test (6.71± 3.49) and control SV lenses (6.82± 3.50 cm). No significant difference was found comparing test and control SV lenses in symptoms of DA (p=0.20). Conclusions The +0.40 D lenses have no negative impact on convergence or loss of accommodation power. The +0.40 D and control SV lenses had a similar impact on attenuating symptoms of DA. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802022000100225 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802022000100225 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.37039/1982.8551.20220054 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Oftalmologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Oftalmologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Oftalmologia v.81 2022 reponame:Revista Brasileira de Oftalmologia (Online) instname:Sociedade Brasileira de Oftalmologia (SBO) instacron:SBO |
instname_str |
Sociedade Brasileira de Oftalmologia (SBO) |
instacron_str |
SBO |
institution |
SBO |
reponame_str |
Revista Brasileira de Oftalmologia (Online) |
collection |
Revista Brasileira de Oftalmologia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO) |
repository.mail.fl_str_mv |
sob@sboportal.org.br||rbo@sboportal.org.br |
_version_ |
1752122339590406144 |