Evaluation of the effects of single vision lenses with additional near-power on computer-induced asthenopia

Detalhes bibliográficos
Autor(a) principal: Alionis,Aline Cristina Fioravanti Lui
Data de Publicação: 2020
Outros Autores: Lui Netto,Adamo, Netto,Tatiana Adarli Fioravanti Lui, Alves,Milton Ruiz
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802020000500325
Resumo: Abstract Objective: Compared to standard spectacle lenses, do +0.40 EyeZenTM lenses reduce symptoms of asthenopia induced by computer? Methods: A prospective clinical study was carried out with 39 volunteers who spent more than 4 hours a day using a computer (age, 27.31±4.24; male: female =13:26). Asthenopia and visual comfort were assessed using a questionnaires. All participants completed the asthenopia questionnaire with updated regular lenses (baseline). After 4 weeks of +0.40 Eyezen™ lenses wearing all subjects answered the asthenopia questionnaire and a second questionnaire to establish their level of satisfaction with these lenses. Statistical analysis was performed usind the Shapiro-Wilk test and Wilcoxon test, and p-values less than 0.05 were considered statistically significant. Results: Compared to standard spectacle lenses (baseline), +0.40 EyeZenTM lenses wearing reduced the total asthenopia score from17.44 ± 5.51 to 13.18 ± 10.22 (p < 0.001). Regarding the perception of the visual comfort levels with these lenses in the management of digital devices, more than 90% of subjects said they were entirely or delighted with their visual comfort.. Conclusions: Digital asthenopia induced by computer was significantly reduced by +0.40 EyeZen lenses wearing.
id SBO-1_d2ac02a92d599aa3b57e65c9a7ac4b35
oai_identifier_str oai:scielo:S0034-72802020000500325
network_acronym_str SBO-1
network_name_str Revista Brasileira de Oftalmologia (Online)
repository_id_str
spelling Evaluation of the effects of single vision lenses with additional near-power on computer-induced asthenopiaComputer vision syndromeAsthenopiaOccupational diseasesOccupational medicineAbstract Objective: Compared to standard spectacle lenses, do +0.40 EyeZenTM lenses reduce symptoms of asthenopia induced by computer? Methods: A prospective clinical study was carried out with 39 volunteers who spent more than 4 hours a day using a computer (age, 27.31±4.24; male: female =13:26). Asthenopia and visual comfort were assessed using a questionnaires. All participants completed the asthenopia questionnaire with updated regular lenses (baseline). After 4 weeks of +0.40 Eyezen™ lenses wearing all subjects answered the asthenopia questionnaire and a second questionnaire to establish their level of satisfaction with these lenses. Statistical analysis was performed usind the Shapiro-Wilk test and Wilcoxon test, and p-values less than 0.05 were considered statistically significant. Results: Compared to standard spectacle lenses (baseline), +0.40 EyeZenTM lenses wearing reduced the total asthenopia score from17.44 ± 5.51 to 13.18 ± 10.22 (p < 0.001). Regarding the perception of the visual comfort levels with these lenses in the management of digital devices, more than 90% of subjects said they were entirely or delighted with their visual comfort.. Conclusions: Digital asthenopia induced by computer was significantly reduced by +0.40 EyeZen lenses wearing.Sociedade Brasileira de Oftalmologia2020-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802020000500325Revista Brasileira de Oftalmologia v.79 n.5 2020reponame:Revista Brasileira de Oftalmologia (Online)instname:Sociedade Brasileira de Oftalmologia (SBO)instacron:SBO10.5935/0034-7280.20200069info:eu-repo/semantics/openAccessAlionis,Aline Cristina Fioravanti LuiLui Netto,AdamoNetto,Tatiana Adarli Fioravanti LuiAlves,Milton Ruizeng2020-11-17T00:00:00Zoai:scielo:S0034-72802020000500325Revistahttps://rbo.emnuvens.com.br/rbo/indexhttps://old.scielo.br/oai/scielo-oai.phpsob@sboportal.org.br||rbo@sboportal.org.br1982-85510034-7280opendoar:2020-11-17T00:00Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)false
dc.title.none.fl_str_mv Evaluation of the effects of single vision lenses with additional near-power on computer-induced asthenopia
title Evaluation of the effects of single vision lenses with additional near-power on computer-induced asthenopia
spellingShingle Evaluation of the effects of single vision lenses with additional near-power on computer-induced asthenopia
Alionis,Aline Cristina Fioravanti Lui
Computer vision syndrome
Asthenopia
Occupational diseases
Occupational medicine
title_short Evaluation of the effects of single vision lenses with additional near-power on computer-induced asthenopia
title_full Evaluation of the effects of single vision lenses with additional near-power on computer-induced asthenopia
title_fullStr Evaluation of the effects of single vision lenses with additional near-power on computer-induced asthenopia
title_full_unstemmed Evaluation of the effects of single vision lenses with additional near-power on computer-induced asthenopia
title_sort Evaluation of the effects of single vision lenses with additional near-power on computer-induced asthenopia
author Alionis,Aline Cristina Fioravanti Lui
author_facet Alionis,Aline Cristina Fioravanti Lui
Lui Netto,Adamo
Netto,Tatiana Adarli Fioravanti Lui
Alves,Milton Ruiz
author_role author
author2 Lui Netto,Adamo
Netto,Tatiana Adarli Fioravanti Lui
Alves,Milton Ruiz
author2_role author
author
author
dc.contributor.author.fl_str_mv Alionis,Aline Cristina Fioravanti Lui
Lui Netto,Adamo
Netto,Tatiana Adarli Fioravanti Lui
Alves,Milton Ruiz
dc.subject.por.fl_str_mv Computer vision syndrome
Asthenopia
Occupational diseases
Occupational medicine
topic Computer vision syndrome
Asthenopia
Occupational diseases
Occupational medicine
description Abstract Objective: Compared to standard spectacle lenses, do +0.40 EyeZenTM lenses reduce symptoms of asthenopia induced by computer? Methods: A prospective clinical study was carried out with 39 volunteers who spent more than 4 hours a day using a computer (age, 27.31±4.24; male: female =13:26). Asthenopia and visual comfort were assessed using a questionnaires. All participants completed the asthenopia questionnaire with updated regular lenses (baseline). After 4 weeks of +0.40 Eyezen™ lenses wearing all subjects answered the asthenopia questionnaire and a second questionnaire to establish their level of satisfaction with these lenses. Statistical analysis was performed usind the Shapiro-Wilk test and Wilcoxon test, and p-values less than 0.05 were considered statistically significant. Results: Compared to standard spectacle lenses (baseline), +0.40 EyeZenTM lenses wearing reduced the total asthenopia score from17.44 ± 5.51 to 13.18 ± 10.22 (p < 0.001). Regarding the perception of the visual comfort levels with these lenses in the management of digital devices, more than 90% of subjects said they were entirely or delighted with their visual comfort.. Conclusions: Digital asthenopia induced by computer was significantly reduced by +0.40 EyeZen lenses wearing.
publishDate 2020
dc.date.none.fl_str_mv 2020-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802020000500325
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802020000500325
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0034-7280.20200069
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Oftalmologia
publisher.none.fl_str_mv Sociedade Brasileira de Oftalmologia
dc.source.none.fl_str_mv Revista Brasileira de Oftalmologia v.79 n.5 2020
reponame:Revista Brasileira de Oftalmologia (Online)
instname:Sociedade Brasileira de Oftalmologia (SBO)
instacron:SBO
instname_str Sociedade Brasileira de Oftalmologia (SBO)
instacron_str SBO
institution SBO
reponame_str Revista Brasileira de Oftalmologia (Online)
collection Revista Brasileira de Oftalmologia (Online)
repository.name.fl_str_mv Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)
repository.mail.fl_str_mv sob@sboportal.org.br||rbo@sboportal.org.br
_version_ 1752122339119595520