THE CORRECT IMPLANT CHOICE FOR TRANSTROCHANTERIC FRACTURE IN BRAZIL
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Acta Ortopédica Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522016000600327 |
Resumo: | ABSTRACT Objective: To assess the adequacy to the Brazilian population of orthopedic implants used for treatment of proximal femoral fractures. Methods: The neck-shaft angle of the femur of 101 patients was measured in anteroposterior pelvis radiographs and these measurements were correlated to gender, age, height, weight and ethnicity. In addition, we compared the values of the neck -shaft angle with the angulation of the main implants available in the Brazilian market for the treatment of transtrochanteric fractures. Results: Of the 101 measurements, an average of 130.9±6.7° was obtained, ranging from 112° to 150°. Correlating these measurements with epidemiological variables, only age was statistically significant. Conclusion: Most of the analyzed population presented anatomical characteristics that allow the proper use of these implants to treat transtrochanteric fractures, as indicated from the analysis of neck-shaft angles. Nonetheless, 4% of individuals did not fit this pattern and would have required alternative implants. Level of Evidence III, Study of nonconsecutive patients; without consistently applied reference ''gold'' standard. |
id |
SBOT-1_3e7e0df0e49b0bc0dd9d69a8079c8588 |
---|---|
oai_identifier_str |
oai:scielo:S1413-78522016000600327 |
network_acronym_str |
SBOT-1 |
network_name_str |
Acta Ortopédica Brasileira (Online) |
repository_id_str |
|
spelling |
THE CORRECT IMPLANT CHOICE FOR TRANSTROCHANTERIC FRACTURE IN BRAZILHip fracturesFracture fixationFemur neckABSTRACT Objective: To assess the adequacy to the Brazilian population of orthopedic implants used for treatment of proximal femoral fractures. Methods: The neck-shaft angle of the femur of 101 patients was measured in anteroposterior pelvis radiographs and these measurements were correlated to gender, age, height, weight and ethnicity. In addition, we compared the values of the neck -shaft angle with the angulation of the main implants available in the Brazilian market for the treatment of transtrochanteric fractures. Results: Of the 101 measurements, an average of 130.9±6.7° was obtained, ranging from 112° to 150°. Correlating these measurements with epidemiological variables, only age was statistically significant. Conclusion: Most of the analyzed population presented anatomical characteristics that allow the proper use of these implants to treat transtrochanteric fractures, as indicated from the analysis of neck-shaft angles. Nonetheless, 4% of individuals did not fit this pattern and would have required alternative implants. Level of Evidence III, Study of nonconsecutive patients; without consistently applied reference ''gold'' standard.ATHA EDITORA2016-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522016000600327Acta Ortopédica Brasileira v.24 n.6 2016reponame:Acta Ortopédica Brasileira (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1590/1413-785220162406158264info:eu-repo/semantics/openAccessTorquato,Diogo FernandesBordini,André FigueiredoFerreira,GustavoTakata,Edmilson TakehiroTrigueiro,GustavoBasile,Ricardopor2016-12-12T00:00:00Zoai:scielo:S1413-78522016000600327Revistahttp://www.actaortopedica.com.br/https://old.scielo.br/oai/scielo-oai.php1atha@uol.com.br||actaortopedicabrasileira@uol.com.br1809-44061413-7852opendoar:2016-12-12T00:00Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false |
dc.title.none.fl_str_mv |
THE CORRECT IMPLANT CHOICE FOR TRANSTROCHANTERIC FRACTURE IN BRAZIL |
title |
THE CORRECT IMPLANT CHOICE FOR TRANSTROCHANTERIC FRACTURE IN BRAZIL |
spellingShingle |
THE CORRECT IMPLANT CHOICE FOR TRANSTROCHANTERIC FRACTURE IN BRAZIL Torquato,Diogo Fernandes Hip fractures Fracture fixation Femur neck |
title_short |
THE CORRECT IMPLANT CHOICE FOR TRANSTROCHANTERIC FRACTURE IN BRAZIL |
title_full |
THE CORRECT IMPLANT CHOICE FOR TRANSTROCHANTERIC FRACTURE IN BRAZIL |
title_fullStr |
THE CORRECT IMPLANT CHOICE FOR TRANSTROCHANTERIC FRACTURE IN BRAZIL |
title_full_unstemmed |
THE CORRECT IMPLANT CHOICE FOR TRANSTROCHANTERIC FRACTURE IN BRAZIL |
title_sort |
THE CORRECT IMPLANT CHOICE FOR TRANSTROCHANTERIC FRACTURE IN BRAZIL |
author |
Torquato,Diogo Fernandes |
author_facet |
Torquato,Diogo Fernandes Bordini,André Figueiredo Ferreira,Gustavo Takata,Edmilson Takehiro Trigueiro,Gustavo Basile,Ricardo |
author_role |
author |
author2 |
Bordini,André Figueiredo Ferreira,Gustavo Takata,Edmilson Takehiro Trigueiro,Gustavo Basile,Ricardo |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Torquato,Diogo Fernandes Bordini,André Figueiredo Ferreira,Gustavo Takata,Edmilson Takehiro Trigueiro,Gustavo Basile,Ricardo |
dc.subject.por.fl_str_mv |
Hip fractures Fracture fixation Femur neck |
topic |
Hip fractures Fracture fixation Femur neck |
description |
ABSTRACT Objective: To assess the adequacy to the Brazilian population of orthopedic implants used for treatment of proximal femoral fractures. Methods: The neck-shaft angle of the femur of 101 patients was measured in anteroposterior pelvis radiographs and these measurements were correlated to gender, age, height, weight and ethnicity. In addition, we compared the values of the neck -shaft angle with the angulation of the main implants available in the Brazilian market for the treatment of transtrochanteric fractures. Results: Of the 101 measurements, an average of 130.9±6.7° was obtained, ranging from 112° to 150°. Correlating these measurements with epidemiological variables, only age was statistically significant. Conclusion: Most of the analyzed population presented anatomical characteristics that allow the proper use of these implants to treat transtrochanteric fractures, as indicated from the analysis of neck-shaft angles. Nonetheless, 4% of individuals did not fit this pattern and would have required alternative implants. Level of Evidence III, Study of nonconsecutive patients; without consistently applied reference ''gold'' standard. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522016000600327 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522016000600327 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
10.1590/1413-785220162406158264 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
ATHA EDITORA |
publisher.none.fl_str_mv |
ATHA EDITORA |
dc.source.none.fl_str_mv |
Acta Ortopédica Brasileira v.24 n.6 2016 reponame:Acta Ortopédica Brasileira (Online) instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) instacron:SBOT |
instname_str |
Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
instacron_str |
SBOT |
institution |
SBOT |
reponame_str |
Acta Ortopédica Brasileira (Online) |
collection |
Acta Ortopédica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
repository.mail.fl_str_mv |
1atha@uol.com.br||actaortopedicabrasileira@uol.com.br |
_version_ |
1752122275586375680 |