The correct implant choice for transtrochanteric fracture in Brazil

Detalhes bibliográficos
Autor(a) principal: Torquato, Diogo Fernandes [UNIFESP]
Data de Publicação: 2016
Outros Autores: Bordini, Andre Figueiredo [UNIFESP], Ferreira, Gustavo [UNIFESP], Takata, Edmilson Takehiro [UNIFESP], Trigueiro, Gustavo [UNIFESP], Basile, Ricardo [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/1413-785220162406158264
https://repositorio.unifesp.br/handle/11600/56756
Resumo: Objective: To assess the adequacy to the Brazilian population of orthopedic implants used for treatment of proximal femoral fractures. Methods: The neck-shaft angle of the femur of 101 patients was measured in anteroposterior pelvis radiographs and these measurements were correlated to gender, age, height, weight and ethnicity. In addition, we compared the values of the neck-shaft angle with the angulation of the main implants available in the Brazilian market for the treatment of transtrochanteric fractures. Results: Of the 101 measurements, an average of 130.9 +/- 6.7 degrees was obtained, ranging from 112 degrees to 150 degrees. Correlating these measurements with epidemiological variables, only age was statistically significant. Conclusion: Most of the analyzed population presented anatomical characteristics that allow the proper use of these implants to treat transtrochanteric fractures, as indicated from the analysis of neck-shaft angles. Nonetheless, 4% of individuals did not fit this pattern and would have required alternative implants.
id UFSP_fc35c68c61fa3778ad3c0a503a7dc568
oai_identifier_str oai:repositorio.unifesp.br/:11600/56756
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling The correct implant choice for transtrochanteric fracture in BrazilHip fracturesFracture fixationFemur neckObjective: To assess the adequacy to the Brazilian population of orthopedic implants used for treatment of proximal femoral fractures. Methods: The neck-shaft angle of the femur of 101 patients was measured in anteroposterior pelvis radiographs and these measurements were correlated to gender, age, height, weight and ethnicity. In addition, we compared the values of the neck-shaft angle with the angulation of the main implants available in the Brazilian market for the treatment of transtrochanteric fractures. Results: Of the 101 measurements, an average of 130.9 +/- 6.7 degrees was obtained, ranging from 112 degrees to 150 degrees. Correlating these measurements with epidemiological variables, only age was statistically significant. Conclusion: Most of the analyzed population presented anatomical characteristics that allow the proper use of these implants to treat transtrochanteric fractures, as indicated from the analysis of neck-shaft angles. Nonetheless, 4% of individuals did not fit this pattern and would have required alternative implants.Univ Fed Sao Paulo, Escola Paulista Med, Hosp Sao Paulo, Adult Hip Pathol Outpatient, Sao Paulo, SP, BrazilUniversidade Federal de São Paulo, Escola Paulista de Medicina, Department of Orthopedics and Traumatology, Group of Adult Hip Pathologies, São Paulo, SP, BrazilWeb of ScienceAtha Comunicacao & Editora2020-07-31T12:47:20Z2020-07-31T12:47:20Z2016info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion327-329http://dx.doi.org/10.1590/1413-785220162406158264Acta Ortopedica Brasileira. Sao Paulo Sp, v. 24, n. 6, p. 327-329, 2016.10.1590/1413-785220162406158264S1413-78522016000600327.pdf1413-7852S1413-78522016000600327https://repositorio.unifesp.br/handle/11600/56756WOS:000392919400009engActa Ortopedica BrasileiraSao Paulo Spinfo:eu-repo/semantics/openAccessTorquato, Diogo Fernandes [UNIFESP]Bordini, Andre Figueiredo [UNIFESP]Ferreira, Gustavo [UNIFESP]Takata, Edmilson Takehiro [UNIFESP]Trigueiro, Gustavo [UNIFESP]Basile, Ricardo [UNIFESP]reponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2022-02-10T17:31:17Zoai:repositorio.unifesp.br/:11600/56756Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652022-02-10T17:31:17Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv The correct implant choice for transtrochanteric fracture in Brazil
title The correct implant choice for transtrochanteric fracture in Brazil
spellingShingle The correct implant choice for transtrochanteric fracture in Brazil
Torquato, Diogo Fernandes [UNIFESP]
Hip fractures
Fracture fixation
Femur neck
title_short The correct implant choice for transtrochanteric fracture in Brazil
title_full The correct implant choice for transtrochanteric fracture in Brazil
title_fullStr The correct implant choice for transtrochanteric fracture in Brazil
title_full_unstemmed The correct implant choice for transtrochanteric fracture in Brazil
title_sort The correct implant choice for transtrochanteric fracture in Brazil
author Torquato, Diogo Fernandes [UNIFESP]
author_facet Torquato, Diogo Fernandes [UNIFESP]
Bordini, Andre Figueiredo [UNIFESP]
Ferreira, Gustavo [UNIFESP]
Takata, Edmilson Takehiro [UNIFESP]
Trigueiro, Gustavo [UNIFESP]
Basile, Ricardo [UNIFESP]
author_role author
author2 Bordini, Andre Figueiredo [UNIFESP]
Ferreira, Gustavo [UNIFESP]
Takata, Edmilson Takehiro [UNIFESP]
Trigueiro, Gustavo [UNIFESP]
Basile, Ricardo [UNIFESP]
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Torquato, Diogo Fernandes [UNIFESP]
Bordini, Andre Figueiredo [UNIFESP]
Ferreira, Gustavo [UNIFESP]
Takata, Edmilson Takehiro [UNIFESP]
Trigueiro, Gustavo [UNIFESP]
Basile, Ricardo [UNIFESP]
dc.subject.por.fl_str_mv Hip fractures
Fracture fixation
Femur neck
topic Hip fractures
Fracture fixation
Femur neck
description Objective: To assess the adequacy to the Brazilian population of orthopedic implants used for treatment of proximal femoral fractures. Methods: The neck-shaft angle of the femur of 101 patients was measured in anteroposterior pelvis radiographs and these measurements were correlated to gender, age, height, weight and ethnicity. In addition, we compared the values of the neck-shaft angle with the angulation of the main implants available in the Brazilian market for the treatment of transtrochanteric fractures. Results: Of the 101 measurements, an average of 130.9 +/- 6.7 degrees was obtained, ranging from 112 degrees to 150 degrees. Correlating these measurements with epidemiological variables, only age was statistically significant. Conclusion: Most of the analyzed population presented anatomical characteristics that allow the proper use of these implants to treat transtrochanteric fractures, as indicated from the analysis of neck-shaft angles. Nonetheless, 4% of individuals did not fit this pattern and would have required alternative implants.
publishDate 2016
dc.date.none.fl_str_mv 2016
2020-07-31T12:47:20Z
2020-07-31T12:47:20Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/1413-785220162406158264
Acta Ortopedica Brasileira. Sao Paulo Sp, v. 24, n. 6, p. 327-329, 2016.
10.1590/1413-785220162406158264
S1413-78522016000600327.pdf
1413-7852
S1413-78522016000600327
https://repositorio.unifesp.br/handle/11600/56756
WOS:000392919400009
url http://dx.doi.org/10.1590/1413-785220162406158264
https://repositorio.unifesp.br/handle/11600/56756
identifier_str_mv Acta Ortopedica Brasileira. Sao Paulo Sp, v. 24, n. 6, p. 327-329, 2016.
10.1590/1413-785220162406158264
S1413-78522016000600327.pdf
1413-7852
S1413-78522016000600327
WOS:000392919400009
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Acta Ortopedica Brasileira
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 327-329
dc.coverage.none.fl_str_mv Sao Paulo Sp
dc.publisher.none.fl_str_mv Atha Comunicacao & Editora
publisher.none.fl_str_mv Atha Comunicacao & Editora
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268388776607744