The correct implant choice for transtrochanteric fracture in Brazil
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNIFESP |
Texto Completo: | http://dx.doi.org/10.1590/1413-785220162406158264 https://repositorio.unifesp.br/handle/11600/56756 |
Resumo: | Objective: To assess the adequacy to the Brazilian population of orthopedic implants used for treatment of proximal femoral fractures. Methods: The neck-shaft angle of the femur of 101 patients was measured in anteroposterior pelvis radiographs and these measurements were correlated to gender, age, height, weight and ethnicity. In addition, we compared the values of the neck-shaft angle with the angulation of the main implants available in the Brazilian market for the treatment of transtrochanteric fractures. Results: Of the 101 measurements, an average of 130.9 +/- 6.7 degrees was obtained, ranging from 112 degrees to 150 degrees. Correlating these measurements with epidemiological variables, only age was statistically significant. Conclusion: Most of the analyzed population presented anatomical characteristics that allow the proper use of these implants to treat transtrochanteric fractures, as indicated from the analysis of neck-shaft angles. Nonetheless, 4% of individuals did not fit this pattern and would have required alternative implants. |
id |
UFSP_fc35c68c61fa3778ad3c0a503a7dc568 |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/56756 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
The correct implant choice for transtrochanteric fracture in BrazilHip fracturesFracture fixationFemur neckObjective: To assess the adequacy to the Brazilian population of orthopedic implants used for treatment of proximal femoral fractures. Methods: The neck-shaft angle of the femur of 101 patients was measured in anteroposterior pelvis radiographs and these measurements were correlated to gender, age, height, weight and ethnicity. In addition, we compared the values of the neck-shaft angle with the angulation of the main implants available in the Brazilian market for the treatment of transtrochanteric fractures. Results: Of the 101 measurements, an average of 130.9 +/- 6.7 degrees was obtained, ranging from 112 degrees to 150 degrees. Correlating these measurements with epidemiological variables, only age was statistically significant. Conclusion: Most of the analyzed population presented anatomical characteristics that allow the proper use of these implants to treat transtrochanteric fractures, as indicated from the analysis of neck-shaft angles. Nonetheless, 4% of individuals did not fit this pattern and would have required alternative implants.Univ Fed Sao Paulo, Escola Paulista Med, Hosp Sao Paulo, Adult Hip Pathol Outpatient, Sao Paulo, SP, BrazilUniversidade Federal de São Paulo, Escola Paulista de Medicina, Department of Orthopedics and Traumatology, Group of Adult Hip Pathologies, São Paulo, SP, BrazilWeb of ScienceAtha Comunicacao & Editora2020-07-31T12:47:20Z2020-07-31T12:47:20Z2016info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion327-329http://dx.doi.org/10.1590/1413-785220162406158264Acta Ortopedica Brasileira. Sao Paulo Sp, v. 24, n. 6, p. 327-329, 2016.10.1590/1413-785220162406158264S1413-78522016000600327.pdf1413-7852S1413-78522016000600327https://repositorio.unifesp.br/handle/11600/56756WOS:000392919400009engActa Ortopedica BrasileiraSao Paulo Spinfo:eu-repo/semantics/openAccessTorquato, Diogo Fernandes [UNIFESP]Bordini, Andre Figueiredo [UNIFESP]Ferreira, Gustavo [UNIFESP]Takata, Edmilson Takehiro [UNIFESP]Trigueiro, Gustavo [UNIFESP]Basile, Ricardo [UNIFESP]reponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2022-02-10T17:31:17Zoai:repositorio.unifesp.br/:11600/56756Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652022-02-10T17:31:17Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
The correct implant choice for transtrochanteric fracture in Brazil |
title |
The correct implant choice for transtrochanteric fracture in Brazil |
spellingShingle |
The correct implant choice for transtrochanteric fracture in Brazil Torquato, Diogo Fernandes [UNIFESP] Hip fractures Fracture fixation Femur neck |
title_short |
The correct implant choice for transtrochanteric fracture in Brazil |
title_full |
The correct implant choice for transtrochanteric fracture in Brazil |
title_fullStr |
The correct implant choice for transtrochanteric fracture in Brazil |
title_full_unstemmed |
The correct implant choice for transtrochanteric fracture in Brazil |
title_sort |
The correct implant choice for transtrochanteric fracture in Brazil |
author |
Torquato, Diogo Fernandes [UNIFESP] |
author_facet |
Torquato, Diogo Fernandes [UNIFESP] Bordini, Andre Figueiredo [UNIFESP] Ferreira, Gustavo [UNIFESP] Takata, Edmilson Takehiro [UNIFESP] Trigueiro, Gustavo [UNIFESP] Basile, Ricardo [UNIFESP] |
author_role |
author |
author2 |
Bordini, Andre Figueiredo [UNIFESP] Ferreira, Gustavo [UNIFESP] Takata, Edmilson Takehiro [UNIFESP] Trigueiro, Gustavo [UNIFESP] Basile, Ricardo [UNIFESP] |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Torquato, Diogo Fernandes [UNIFESP] Bordini, Andre Figueiredo [UNIFESP] Ferreira, Gustavo [UNIFESP] Takata, Edmilson Takehiro [UNIFESP] Trigueiro, Gustavo [UNIFESP] Basile, Ricardo [UNIFESP] |
dc.subject.por.fl_str_mv |
Hip fractures Fracture fixation Femur neck |
topic |
Hip fractures Fracture fixation Femur neck |
description |
Objective: To assess the adequacy to the Brazilian population of orthopedic implants used for treatment of proximal femoral fractures. Methods: The neck-shaft angle of the femur of 101 patients was measured in anteroposterior pelvis radiographs and these measurements were correlated to gender, age, height, weight and ethnicity. In addition, we compared the values of the neck-shaft angle with the angulation of the main implants available in the Brazilian market for the treatment of transtrochanteric fractures. Results: Of the 101 measurements, an average of 130.9 +/- 6.7 degrees was obtained, ranging from 112 degrees to 150 degrees. Correlating these measurements with epidemiological variables, only age was statistically significant. Conclusion: Most of the analyzed population presented anatomical characteristics that allow the proper use of these implants to treat transtrochanteric fractures, as indicated from the analysis of neck-shaft angles. Nonetheless, 4% of individuals did not fit this pattern and would have required alternative implants. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016 2020-07-31T12:47:20Z 2020-07-31T12:47:20Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/1413-785220162406158264 Acta Ortopedica Brasileira. Sao Paulo Sp, v. 24, n. 6, p. 327-329, 2016. 10.1590/1413-785220162406158264 S1413-78522016000600327.pdf 1413-7852 S1413-78522016000600327 https://repositorio.unifesp.br/handle/11600/56756 WOS:000392919400009 |
url |
http://dx.doi.org/10.1590/1413-785220162406158264 https://repositorio.unifesp.br/handle/11600/56756 |
identifier_str_mv |
Acta Ortopedica Brasileira. Sao Paulo Sp, v. 24, n. 6, p. 327-329, 2016. 10.1590/1413-785220162406158264 S1413-78522016000600327.pdf 1413-7852 S1413-78522016000600327 WOS:000392919400009 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Acta Ortopedica Brasileira |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
327-329 |
dc.coverage.none.fl_str_mv |
Sao Paulo Sp |
dc.publisher.none.fl_str_mv |
Atha Comunicacao & Editora |
publisher.none.fl_str_mv |
Atha Comunicacao & Editora |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1814268388776607744 |