PERPENDICULAR DOUBLE-PLATE FIXATION WITH LOCKING SYSTEM FOR ACROMION PEDICLE FRACTURE

Detalhes bibliográficos
Autor(a) principal: Zhu,Junkun
Data de Publicação: 2016
Outros Autores: Pan,Zhijun, Zheng,Rongzong, Lan,Shuhua
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Ortopédica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522016000200107
Resumo: Objective : To describe the surgical technique and preliminary clinical outcomes in a series of open reduction internal fixation of basal acromion process fractures applying a double-plating technique. Methods : Nine consecutive patients, mean age 33.4 years old (range, 23-61 years old) with unilateral acromion fracture (Type 3 AO/OTA) with more than 1cm displacement who underwent fixation utilizing a locked double-plating technique, were evaluated on average at 7.8 months (range, 3-15 months) for outcomes related to pain, shoulder function, and surgical complications. Results : Eight patients recovered with complete radiographic union and favorable shoulder function. One case failed to be fully evaluated for more than 3 months follow-up. The overall scores of Constant, Shoulder Pain and Disability Index (SPADI) and DASH for the eight patients reviewed were 91.9± 6.31, 3.11± 3.79 and 5.2± 6.35, respectively. No post-operative infection or surgical hardware irritation was identified at final follow-up of these eight patients. Conclusion : While more evidence is needed to justify its advantages over traditional implants, perpendicular double-plate with a locking system may be indicated for acromion pedicle fracture treatment, since it performed well for fracture healing and joint function rehabilitation. Level of Evidence IV, Therapeutic Study.
id SBOT-1_6986ecf7a70b8d0563103639f4ca71ce
oai_identifier_str oai:scielo:S1413-78522016000200107
network_acronym_str SBOT-1
network_name_str Acta Ortopédica Brasileira (Online)
repository_id_str
spelling PERPENDICULAR DOUBLE-PLATE FIXATION WITH LOCKING SYSTEM FOR ACROMION PEDICLE FRACTUREFractures, boneAcromionFracture Fixation, Internal Objective : To describe the surgical technique and preliminary clinical outcomes in a series of open reduction internal fixation of basal acromion process fractures applying a double-plating technique. Methods : Nine consecutive patients, mean age 33.4 years old (range, 23-61 years old) with unilateral acromion fracture (Type 3 AO/OTA) with more than 1cm displacement who underwent fixation utilizing a locked double-plating technique, were evaluated on average at 7.8 months (range, 3-15 months) for outcomes related to pain, shoulder function, and surgical complications. Results : Eight patients recovered with complete radiographic union and favorable shoulder function. One case failed to be fully evaluated for more than 3 months follow-up. The overall scores of Constant, Shoulder Pain and Disability Index (SPADI) and DASH for the eight patients reviewed were 91.9± 6.31, 3.11± 3.79 and 5.2± 6.35, respectively. No post-operative infection or surgical hardware irritation was identified at final follow-up of these eight patients. Conclusion : While more evidence is needed to justify its advantages over traditional implants, perpendicular double-plate with a locking system may be indicated for acromion pedicle fracture treatment, since it performed well for fracture healing and joint function rehabilitation. Level of Evidence IV, Therapeutic Study.ATHA EDITORA2016-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522016000200107Acta Ortopédica Brasileira v.24 n.2 2016reponame:Acta Ortopédica Brasileira (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1590/1413-785220162402141691info:eu-repo/semantics/openAccessZhu,JunkunPan,ZhijunZheng,RongzongLan,Shuhuaeng2016-06-03T00:00:00Zoai:scielo:S1413-78522016000200107Revistahttp://www.actaortopedica.com.br/https://old.scielo.br/oai/scielo-oai.php1atha@uol.com.br||actaortopedicabrasileira@uol.com.br1809-44061413-7852opendoar:2016-06-03T00:00Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false
dc.title.none.fl_str_mv PERPENDICULAR DOUBLE-PLATE FIXATION WITH LOCKING SYSTEM FOR ACROMION PEDICLE FRACTURE
title PERPENDICULAR DOUBLE-PLATE FIXATION WITH LOCKING SYSTEM FOR ACROMION PEDICLE FRACTURE
spellingShingle PERPENDICULAR DOUBLE-PLATE FIXATION WITH LOCKING SYSTEM FOR ACROMION PEDICLE FRACTURE
Zhu,Junkun
Fractures, bone
Acromion
Fracture Fixation, Internal
title_short PERPENDICULAR DOUBLE-PLATE FIXATION WITH LOCKING SYSTEM FOR ACROMION PEDICLE FRACTURE
title_full PERPENDICULAR DOUBLE-PLATE FIXATION WITH LOCKING SYSTEM FOR ACROMION PEDICLE FRACTURE
title_fullStr PERPENDICULAR DOUBLE-PLATE FIXATION WITH LOCKING SYSTEM FOR ACROMION PEDICLE FRACTURE
title_full_unstemmed PERPENDICULAR DOUBLE-PLATE FIXATION WITH LOCKING SYSTEM FOR ACROMION PEDICLE FRACTURE
title_sort PERPENDICULAR DOUBLE-PLATE FIXATION WITH LOCKING SYSTEM FOR ACROMION PEDICLE FRACTURE
author Zhu,Junkun
author_facet Zhu,Junkun
Pan,Zhijun
Zheng,Rongzong
Lan,Shuhua
author_role author
author2 Pan,Zhijun
Zheng,Rongzong
Lan,Shuhua
author2_role author
author
author
dc.contributor.author.fl_str_mv Zhu,Junkun
Pan,Zhijun
Zheng,Rongzong
Lan,Shuhua
dc.subject.por.fl_str_mv Fractures, bone
Acromion
Fracture Fixation, Internal
topic Fractures, bone
Acromion
Fracture Fixation, Internal
description Objective : To describe the surgical technique and preliminary clinical outcomes in a series of open reduction internal fixation of basal acromion process fractures applying a double-plating technique. Methods : Nine consecutive patients, mean age 33.4 years old (range, 23-61 years old) with unilateral acromion fracture (Type 3 AO/OTA) with more than 1cm displacement who underwent fixation utilizing a locked double-plating technique, were evaluated on average at 7.8 months (range, 3-15 months) for outcomes related to pain, shoulder function, and surgical complications. Results : Eight patients recovered with complete radiographic union and favorable shoulder function. One case failed to be fully evaluated for more than 3 months follow-up. The overall scores of Constant, Shoulder Pain and Disability Index (SPADI) and DASH for the eight patients reviewed were 91.9± 6.31, 3.11± 3.79 and 5.2± 6.35, respectively. No post-operative infection or surgical hardware irritation was identified at final follow-up of these eight patients. Conclusion : While more evidence is needed to justify its advantages over traditional implants, perpendicular double-plate with a locking system may be indicated for acromion pedicle fracture treatment, since it performed well for fracture healing and joint function rehabilitation. Level of Evidence IV, Therapeutic Study.
publishDate 2016
dc.date.none.fl_str_mv 2016-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522016000200107
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522016000200107
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1413-785220162402141691
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv ATHA EDITORA
publisher.none.fl_str_mv ATHA EDITORA
dc.source.none.fl_str_mv Acta Ortopédica Brasileira v.24 n.2 2016
reponame:Acta Ortopédica Brasileira (Online)
instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron:SBOT
instname_str Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron_str SBOT
institution SBOT
reponame_str Acta Ortopédica Brasileira (Online)
collection Acta Ortopédica Brasileira (Online)
repository.name.fl_str_mv Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
repository.mail.fl_str_mv 1atha@uol.com.br||actaortopedicabrasileira@uol.com.br
_version_ 1752122275498295296