Resumo: | ABSTRACT Objectives To analyze the results of biomechanical assays of the fixation of Pauwels type II femoral neck fractures in synthetic bones, using two parallel cannulated screws or three cannulated screws in an inverted pyramid formation. Methods Ten Brazilian-made synthetic bones were divided into 2 groups. Groups A and B utilized three and two cannulated screws, respectively, after osteotomy in the middle third of the femur, perpendicular to the axis of the femoral neck, simulating a Pauwels type II femoral neck fracture. The resistance of these fixations was analyzed by compression on the axis of the force resulting from hip compression, simulated with a manual hydraulic press. The T-test and post hoc analysis were used to compare the groups, and the significance criterion adopted was p < 0.05. Results In group A, which used fixation with three screws, synthesis failure was seen at a mean force of 526 N. In group B, which used two screws, the mean force was 466 N. The results presented a statistically significant difference (p = 0.02). Conclusion The osteosynthesis of femoral neck fractures in synthetic bone fixated with two screws presented inferior results to fixation with three screws. Level of Evidence III; Case-control study. |
id |
SBOT-1_8b15292c44b209040c1c28a7fecf4ec9 |
---|---|
oai_identifier_str |
oai:scielo:S1413-78522018000300162 |
network_acronym_str |
SBOT-1 |
network_name_str |
Acta Ortopédica Brasileira (Online) |
repository_id_str |
|
spelling |
BIOMECHANICAL ANALYSIS OF FEMORAL NECK FRACTURE FIXATION IN SYNTHETIC BONEBone screwsFemoral neckHip fracturesABSTRACT Objectives To analyze the results of biomechanical assays of the fixation of Pauwels type II femoral neck fractures in synthetic bones, using two parallel cannulated screws or three cannulated screws in an inverted pyramid formation. Methods Ten Brazilian-made synthetic bones were divided into 2 groups. Groups A and B utilized three and two cannulated screws, respectively, after osteotomy in the middle third of the femur, perpendicular to the axis of the femoral neck, simulating a Pauwels type II femoral neck fracture. The resistance of these fixations was analyzed by compression on the axis of the force resulting from hip compression, simulated with a manual hydraulic press. The T-test and post hoc analysis were used to compare the groups, and the significance criterion adopted was p < 0.05. Results In group A, which used fixation with three screws, synthesis failure was seen at a mean force of 526 N. In group B, which used two screws, the mean force was 466 N. The results presented a statistically significant difference (p = 0.02). Conclusion The osteosynthesis of femoral neck fractures in synthetic bone fixated with two screws presented inferior results to fixation with three screws. Level of Evidence III; Case-control study.ATHA EDITORA2018-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522018000300162Acta Ortopédica Brasileira v.26 n.3 2018reponame:Acta Ortopédica Brasileira (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1590/1413-785220182603182288info:eu-repo/semantics/openAccessMANSUR,HENRIQUEALVAREZ,RAFAELFREITAS,ANDERSONGONÇALVES,CESAR BARBOSARAMOS,MAX ROGERIO FREITASeng2018-06-12T00:00:00Zoai:scielo:S1413-78522018000300162Revistahttp://www.actaortopedica.com.br/https://old.scielo.br/oai/scielo-oai.php1atha@uol.com.br||actaortopedicabrasileira@uol.com.br1809-44061413-7852opendoar:2018-06-12T00:00Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false |
dc.title.none.fl_str_mv |
BIOMECHANICAL ANALYSIS OF FEMORAL NECK FRACTURE FIXATION IN SYNTHETIC BONE |
title |
BIOMECHANICAL ANALYSIS OF FEMORAL NECK FRACTURE FIXATION IN SYNTHETIC BONE |
spellingShingle |
BIOMECHANICAL ANALYSIS OF FEMORAL NECK FRACTURE FIXATION IN SYNTHETIC BONE MANSUR,HENRIQUE Bone screws Femoral neck Hip fractures |
title_short |
BIOMECHANICAL ANALYSIS OF FEMORAL NECK FRACTURE FIXATION IN SYNTHETIC BONE |
title_full |
BIOMECHANICAL ANALYSIS OF FEMORAL NECK FRACTURE FIXATION IN SYNTHETIC BONE |
title_fullStr |
BIOMECHANICAL ANALYSIS OF FEMORAL NECK FRACTURE FIXATION IN SYNTHETIC BONE |
title_full_unstemmed |
BIOMECHANICAL ANALYSIS OF FEMORAL NECK FRACTURE FIXATION IN SYNTHETIC BONE |
title_sort |
BIOMECHANICAL ANALYSIS OF FEMORAL NECK FRACTURE FIXATION IN SYNTHETIC BONE |
author |
MANSUR,HENRIQUE |
author_facet |
MANSUR,HENRIQUE ALVAREZ,RAFAEL FREITAS,ANDERSON GONÇALVES,CESAR BARBOSA RAMOS,MAX ROGERIO FREITAS |
author_role |
author |
author2 |
ALVAREZ,RAFAEL FREITAS,ANDERSON GONÇALVES,CESAR BARBOSA RAMOS,MAX ROGERIO FREITAS |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
MANSUR,HENRIQUE ALVAREZ,RAFAEL FREITAS,ANDERSON GONÇALVES,CESAR BARBOSA RAMOS,MAX ROGERIO FREITAS |
dc.subject.por.fl_str_mv |
Bone screws Femoral neck Hip fractures |
topic |
Bone screws Femoral neck Hip fractures |
description |
ABSTRACT Objectives To analyze the results of biomechanical assays of the fixation of Pauwels type II femoral neck fractures in synthetic bones, using two parallel cannulated screws or three cannulated screws in an inverted pyramid formation. Methods Ten Brazilian-made synthetic bones were divided into 2 groups. Groups A and B utilized three and two cannulated screws, respectively, after osteotomy in the middle third of the femur, perpendicular to the axis of the femoral neck, simulating a Pauwels type II femoral neck fracture. The resistance of these fixations was analyzed by compression on the axis of the force resulting from hip compression, simulated with a manual hydraulic press. The T-test and post hoc analysis were used to compare the groups, and the significance criterion adopted was p < 0.05. Results In group A, which used fixation with three screws, synthesis failure was seen at a mean force of 526 N. In group B, which used two screws, the mean force was 466 N. The results presented a statistically significant difference (p = 0.02). Conclusion The osteosynthesis of femoral neck fractures in synthetic bone fixated with two screws presented inferior results to fixation with three screws. Level of Evidence III; Case-control study. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522018000300162 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522018000300162 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1413-785220182603182288 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
ATHA EDITORA |
publisher.none.fl_str_mv |
ATHA EDITORA |
dc.source.none.fl_str_mv |
Acta Ortopédica Brasileira v.26 n.3 2018 reponame:Acta Ortopédica Brasileira (Online) instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) instacron:SBOT |
instname_str |
Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
instacron_str |
SBOT |
institution |
SBOT |
reponame_str |
Acta Ortopédica Brasileira (Online) |
collection |
Acta Ortopédica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
repository.mail.fl_str_mv |
1atha@uol.com.br||actaortopedicabrasileira@uol.com.br |
_version_ |
1752122276029923328 |