Mechanical analysis of femoral neck fracture fixation in synthetic bone

Detalhes bibliográficos
Autor(a) principal: Freitas,Anderson
Data de Publicação: 2014
Outros Autores: Azevedo,Bruna Alves Soares, Souza,Roberto Rodrigues de, Costa,Hélio Ismael da, Maciel,Rafael Almeida, Souto,Diogo Ranier de Macedo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Ortopédica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522014000300155
Resumo: OBJECTIVE: To analyze statistically results obtained between biomechanical assays on fixation of femoral neck fracture type Pauwels III, on synthetic bone, using 7.5 mm non parallel cannulated screws and control group. METHODS: Ten synthetic bones from a national brand were used. Test group: fixation of 70(o) tilt femoral neck osteotomy was performed using three 7.5 mm non parallel cannulated screws. We analyzed the resistance of this fixation with 5 mm of displacement, and rotational deviation (phase 1) and with 10 mm offset (phase 2). Control group: the models were tested in their integrity until the femoral neck fracture occurred. RESULTS: the values of the test group in phase 1, in sample 1-5 had a mean of 517N and SD = 96N. Rotational deviations showed a mean of 3.79° e SD = 2. 03°. In phase 2, mean was 649N and SD = 94N. The values of the maximum load in the control group were: 1544N, 1110N, 1359N, 1194N, 1437N; respectively. Statistical analysis between the groups showed a statistically significant lower value in the test group. CONCLUSION: the analysis of mechanical resistance between the groups has determined statistically significant value for the test group. Level of Evidence III, Case-control Study.
id SBOT-1_4169add29af808da4789e7bc17b2c355
oai_identifier_str oai:scielo:S1413-78522014000300155
network_acronym_str SBOT-1
network_name_str Acta Ortopédica Brasileira (Online)
repository_id_str
spelling Mechanical analysis of femoral neck fracture fixation in synthetic boneFemoral neck fracturesFracture fixation, internalBiomechanical phenomenas OBJECTIVE: To analyze statistically results obtained between biomechanical assays on fixation of femoral neck fracture type Pauwels III, on synthetic bone, using 7.5 mm non parallel cannulated screws and control group. METHODS: Ten synthetic bones from a national brand were used. Test group: fixation of 70(o) tilt femoral neck osteotomy was performed using three 7.5 mm non parallel cannulated screws. We analyzed the resistance of this fixation with 5 mm of displacement, and rotational deviation (phase 1) and with 10 mm offset (phase 2). Control group: the models were tested in their integrity until the femoral neck fracture occurred. RESULTS: the values of the test group in phase 1, in sample 1-5 had a mean of 517N and SD = 96N. Rotational deviations showed a mean of 3.79° e SD = 2. 03°. In phase 2, mean was 649N and SD = 94N. The values of the maximum load in the control group were: 1544N, 1110N, 1359N, 1194N, 1437N; respectively. Statistical analysis between the groups showed a statistically significant lower value in the test group. CONCLUSION: the analysis of mechanical resistance between the groups has determined statistically significant value for the test group. Level of Evidence III, Case-control Study. ATHA EDITORA2014-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522014000300155Acta Ortopédica Brasileira v.22 n.3 2014reponame:Acta Ortopédica Brasileira (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1590/1413-78522014220300914info:eu-repo/semantics/openAccessFreitas,AndersonAzevedo,Bruna Alves SoaresSouza,Roberto Rodrigues deCosta,Hélio Ismael daMaciel,Rafael AlmeidaSouto,Diogo Ranier de Macedoeng2015-08-03T00:00:00Zoai:scielo:S1413-78522014000300155Revistahttp://www.actaortopedica.com.br/https://old.scielo.br/oai/scielo-oai.php1atha@uol.com.br||actaortopedicabrasileira@uol.com.br1809-44061413-7852opendoar:2015-08-03T00:00Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false
dc.title.none.fl_str_mv Mechanical analysis of femoral neck fracture fixation in synthetic bone
title Mechanical analysis of femoral neck fracture fixation in synthetic bone
spellingShingle Mechanical analysis of femoral neck fracture fixation in synthetic bone
Freitas,Anderson
Femoral neck fractures
Fracture fixation, internal
Biomechanical phenomenas
title_short Mechanical analysis of femoral neck fracture fixation in synthetic bone
title_full Mechanical analysis of femoral neck fracture fixation in synthetic bone
title_fullStr Mechanical analysis of femoral neck fracture fixation in synthetic bone
title_full_unstemmed Mechanical analysis of femoral neck fracture fixation in synthetic bone
title_sort Mechanical analysis of femoral neck fracture fixation in synthetic bone
author Freitas,Anderson
author_facet Freitas,Anderson
Azevedo,Bruna Alves Soares
Souza,Roberto Rodrigues de
Costa,Hélio Ismael da
Maciel,Rafael Almeida
Souto,Diogo Ranier de Macedo
author_role author
author2 Azevedo,Bruna Alves Soares
Souza,Roberto Rodrigues de
Costa,Hélio Ismael da
Maciel,Rafael Almeida
Souto,Diogo Ranier de Macedo
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Freitas,Anderson
Azevedo,Bruna Alves Soares
Souza,Roberto Rodrigues de
Costa,Hélio Ismael da
Maciel,Rafael Almeida
Souto,Diogo Ranier de Macedo
dc.subject.por.fl_str_mv Femoral neck fractures
Fracture fixation, internal
Biomechanical phenomenas
topic Femoral neck fractures
Fracture fixation, internal
Biomechanical phenomenas
description OBJECTIVE: To analyze statistically results obtained between biomechanical assays on fixation of femoral neck fracture type Pauwels III, on synthetic bone, using 7.5 mm non parallel cannulated screws and control group. METHODS: Ten synthetic bones from a national brand were used. Test group: fixation of 70(o) tilt femoral neck osteotomy was performed using three 7.5 mm non parallel cannulated screws. We analyzed the resistance of this fixation with 5 mm of displacement, and rotational deviation (phase 1) and with 10 mm offset (phase 2). Control group: the models were tested in their integrity until the femoral neck fracture occurred. RESULTS: the values of the test group in phase 1, in sample 1-5 had a mean of 517N and SD = 96N. Rotational deviations showed a mean of 3.79° e SD = 2. 03°. In phase 2, mean was 649N and SD = 94N. The values of the maximum load in the control group were: 1544N, 1110N, 1359N, 1194N, 1437N; respectively. Statistical analysis between the groups showed a statistically significant lower value in the test group. CONCLUSION: the analysis of mechanical resistance between the groups has determined statistically significant value for the test group. Level of Evidence III, Case-control Study.
publishDate 2014
dc.date.none.fl_str_mv 2014-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522014000300155
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522014000300155
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1413-78522014220300914
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv ATHA EDITORA
publisher.none.fl_str_mv ATHA EDITORA
dc.source.none.fl_str_mv Acta Ortopédica Brasileira v.22 n.3 2014
reponame:Acta Ortopédica Brasileira (Online)
instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron:SBOT
instname_str Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron_str SBOT
institution SBOT
reponame_str Acta Ortopédica Brasileira (Online)
collection Acta Ortopédica Brasileira (Online)
repository.name.fl_str_mv Acta Ortopédica Brasileira (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
repository.mail.fl_str_mv 1atha@uol.com.br||actaortopedicabrasileira@uol.com.br
_version_ 1752122274792603648