Meniscal repair by all-inside technique with Fast-Fix device

Detalhes bibliográficos
Autor(a) principal: Albertoni,Leonardo Jose Bernardes
Data de Publicação: 2013
Outros Autores: Schumacher,Felipe Conrado, Ventura,Matheus Henrique Araujo, Franciozi,Carlos Eduardo da Silveira, Debieux,Pedro, Kubota,Marcelo Seiji, Granata Junior,Geraldo Sergio de Mello, Luzo,Marcus Vinicius Malheiros, Queiroz,Antonio Altenor Bessa de, Carneiro Filho,Mario
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Ortopedia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162013000500448
Resumo: OBJECTIVE: The objective of this study is to evaluate the results and effectiveness of the technique of meniscal repair type all-inside using Fast-Fix device. METHODS: A retrospective cohort study evaluating 22 patients with meniscal surgery between January 2004 and December 2010 underwent meniscal repair technique for all-inside with the Fast-Fix device with or without ACL reconstruction. Function and quality of life outcomes were chosen by the IKDC and Lysholm score, before and postoperatively, and reoperation rates, relying to the time of final follow-up. Statistical analysis was performed using the Student's t test. RESULTS: The mean follow-up was 59 months (16-84). The Lysholm score showed 72% (16 patients) of excellent and good results (84-100 points), 27% (6 patients) fair (65-83 points) and no cases classified as poor (<64 points). According to the IKDC: 81% (18 patients) of excellent and good results (75-100 points), 18% of cases regular (50-75 points) and no patient had poor results (<50 points). There were no failures or complications. CONCLUSION: The technique of meniscal repair type all-inside using the Fast-Fix device is safe and effective for the treatment of meniscal lesions in the red zone or red-white with or without simultaneous ACL reconstruction, with good and excellent results in most patients Level 4 Study.
id SBOT-2_65208fc1b2d8019e148febe135d302de
oai_identifier_str oai:scielo:S0102-36162013000500448
network_acronym_str SBOT-2
network_name_str Revista Brasileira de Ortopedia (Online)
repository_id_str
spelling Meniscal repair by all-inside technique with Fast-Fix deviceArthroscopyMenisci tibialSuture techniques OBJECTIVE: The objective of this study is to evaluate the results and effectiveness of the technique of meniscal repair type all-inside using Fast-Fix device. METHODS: A retrospective cohort study evaluating 22 patients with meniscal surgery between January 2004 and December 2010 underwent meniscal repair technique for all-inside with the Fast-Fix device with or without ACL reconstruction. Function and quality of life outcomes were chosen by the IKDC and Lysholm score, before and postoperatively, and reoperation rates, relying to the time of final follow-up. Statistical analysis was performed using the Student's t test. RESULTS: The mean follow-up was 59 months (16-84). The Lysholm score showed 72% (16 patients) of excellent and good results (84-100 points), 27% (6 patients) fair (65-83 points) and no cases classified as poor (<64 points). According to the IKDC: 81% (18 patients) of excellent and good results (75-100 points), 18% of cases regular (50-75 points) and no patient had poor results (<50 points). There were no failures or complications. CONCLUSION: The technique of meniscal repair type all-inside using the Fast-Fix device is safe and effective for the treatment of meniscal lesions in the red zone or red-white with or without simultaneous ACL reconstruction, with good and excellent results in most patients Level 4 Study. Sociedade Brasileira de Ortopedia e Traumatologia2013-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162013000500448Revista Brasileira de Ortopedia v.48 n.5 2013reponame:Revista Brasileira de Ortopedia (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1016/j.rboe.2012.08.010info:eu-repo/semantics/openAccessAlbertoni,Leonardo Jose BernardesSchumacher,Felipe ConradoVentura,Matheus Henrique AraujoFranciozi,Carlos Eduardo da SilveiraDebieux,PedroKubota,Marcelo SeijiGranata Junior,Geraldo Sergio de MelloLuzo,Marcus Vinicius MalheirosQueiroz,Antonio Altenor Bessa deCarneiro Filho,Marioeng2014-02-25T00:00:00Zoai:scielo:S0102-36162013000500448Revistahttp://www.rbo.org.br/https://old.scielo.br/oai/scielo-oai.php||rbo@sbot.org.br1982-43780102-3616opendoar:2014-02-25T00:00Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false
dc.title.none.fl_str_mv Meniscal repair by all-inside technique with Fast-Fix device
title Meniscal repair by all-inside technique with Fast-Fix device
spellingShingle Meniscal repair by all-inside technique with Fast-Fix device
Albertoni,Leonardo Jose Bernardes
Arthroscopy
Menisci tibial
Suture techniques
title_short Meniscal repair by all-inside technique with Fast-Fix device
title_full Meniscal repair by all-inside technique with Fast-Fix device
title_fullStr Meniscal repair by all-inside technique with Fast-Fix device
title_full_unstemmed Meniscal repair by all-inside technique with Fast-Fix device
title_sort Meniscal repair by all-inside technique with Fast-Fix device
author Albertoni,Leonardo Jose Bernardes
author_facet Albertoni,Leonardo Jose Bernardes
Schumacher,Felipe Conrado
Ventura,Matheus Henrique Araujo
Franciozi,Carlos Eduardo da Silveira
Debieux,Pedro
Kubota,Marcelo Seiji
Granata Junior,Geraldo Sergio de Mello
Luzo,Marcus Vinicius Malheiros
Queiroz,Antonio Altenor Bessa de
Carneiro Filho,Mario
author_role author
author2 Schumacher,Felipe Conrado
Ventura,Matheus Henrique Araujo
Franciozi,Carlos Eduardo da Silveira
Debieux,Pedro
Kubota,Marcelo Seiji
Granata Junior,Geraldo Sergio de Mello
Luzo,Marcus Vinicius Malheiros
Queiroz,Antonio Altenor Bessa de
Carneiro Filho,Mario
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Albertoni,Leonardo Jose Bernardes
Schumacher,Felipe Conrado
Ventura,Matheus Henrique Araujo
Franciozi,Carlos Eduardo da Silveira
Debieux,Pedro
Kubota,Marcelo Seiji
Granata Junior,Geraldo Sergio de Mello
Luzo,Marcus Vinicius Malheiros
Queiroz,Antonio Altenor Bessa de
Carneiro Filho,Mario
dc.subject.por.fl_str_mv Arthroscopy
Menisci tibial
Suture techniques
topic Arthroscopy
Menisci tibial
Suture techniques
description OBJECTIVE: The objective of this study is to evaluate the results and effectiveness of the technique of meniscal repair type all-inside using Fast-Fix device. METHODS: A retrospective cohort study evaluating 22 patients with meniscal surgery between January 2004 and December 2010 underwent meniscal repair technique for all-inside with the Fast-Fix device with or without ACL reconstruction. Function and quality of life outcomes were chosen by the IKDC and Lysholm score, before and postoperatively, and reoperation rates, relying to the time of final follow-up. Statistical analysis was performed using the Student's t test. RESULTS: The mean follow-up was 59 months (16-84). The Lysholm score showed 72% (16 patients) of excellent and good results (84-100 points), 27% (6 patients) fair (65-83 points) and no cases classified as poor (<64 points). According to the IKDC: 81% (18 patients) of excellent and good results (75-100 points), 18% of cases regular (50-75 points) and no patient had poor results (<50 points). There were no failures or complications. CONCLUSION: The technique of meniscal repair type all-inside using the Fast-Fix device is safe and effective for the treatment of meniscal lesions in the red zone or red-white with or without simultaneous ACL reconstruction, with good and excellent results in most patients Level 4 Study.
publishDate 2013
dc.date.none.fl_str_mv 2013-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162013000500448
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162013000500448
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.rboe.2012.08.010
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
dc.source.none.fl_str_mv Revista Brasileira de Ortopedia v.48 n.5 2013
reponame:Revista Brasileira de Ortopedia (Online)
instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron:SBOT
instname_str Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron_str SBOT
institution SBOT
reponame_str Revista Brasileira de Ortopedia (Online)
collection Revista Brasileira de Ortopedia (Online)
repository.name.fl_str_mv Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
repository.mail.fl_str_mv ||rbo@sbot.org.br
_version_ 1752122359028908032