Interference of blood storage containing K2EDTA and K3EDTA anticoagulants in the automated analysis of the hemogram
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442020000100419 |
Resumo: | ABSTRACT Introduction: The present work evaluated the possible alterations in different hemogram parameters as: total erythrocyte count, hematocrit, leukocyte, and platelet count, against different times of sample storage at refrigerated and room temperature towards the effects of anticoagulants that can affect the variation of laboratory results. Objective: Compare variations in automated hemogram analysis, with blood collected in tubes containing dipotassium ethylenediaminetetraacetic acid (K2EDTA) and tripotassium ethylenediaminetetraacetic acid (K3EDTA). Material and methods: A comparative study was carried out on differential leukocyte count and absolute leukocyte count, hemoglobin determination and red blood cell count and platelet count. Therefore, it researches the anticoagulant that brings less interferences in hemogram analysis according to storage, at temperatures from 2°C to 8°C and 25°C (room temperature), and the time window between collection and analysis (4, 6, and 8 hours). These determinations were carried out after homogenization from five to eight inversions using the automated device Sysmex XN-1000TM. Eighteen biological samples of venous blood were collected, used as control, from patients aged 18 and over that did not have any hematologic disease. Results: The results were evaluated through descriptive statistical analysis, and comparison of mean values through the analysis of variance (Anova). In accordance with the results presented, there were not changes in the parameters by refrigerating the sample in the period of 8 hours, except for the platelet count, presenting oscillations when stored under refrigeration from 2°C to 8°C. Conclusion: At room temperature, the parameters mean corpuscular volume (MCV), mean corpuscular hemoglobin concentration (MCHC), and hematocrit presented significant statistical differences. |
id |
SBP-1_ad5b150c6a75ed1c4d12f7c636a24b36 |
---|---|
oai_identifier_str |
oai:scielo:S1676-24442020000100419 |
network_acronym_str |
SBP-1 |
network_name_str |
Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) |
repository_id_str |
|
spelling |
Interference of blood storage containing K2EDTA and K3EDTA anticoagulants in the automated analysis of the hemogramedetic acidblood cell countanticoagulantsABSTRACT Introduction: The present work evaluated the possible alterations in different hemogram parameters as: total erythrocyte count, hematocrit, leukocyte, and platelet count, against different times of sample storage at refrigerated and room temperature towards the effects of anticoagulants that can affect the variation of laboratory results. Objective: Compare variations in automated hemogram analysis, with blood collected in tubes containing dipotassium ethylenediaminetetraacetic acid (K2EDTA) and tripotassium ethylenediaminetetraacetic acid (K3EDTA). Material and methods: A comparative study was carried out on differential leukocyte count and absolute leukocyte count, hemoglobin determination and red blood cell count and platelet count. Therefore, it researches the anticoagulant that brings less interferences in hemogram analysis according to storage, at temperatures from 2°C to 8°C and 25°C (room temperature), and the time window between collection and analysis (4, 6, and 8 hours). These determinations were carried out after homogenization from five to eight inversions using the automated device Sysmex XN-1000TM. Eighteen biological samples of venous blood were collected, used as control, from patients aged 18 and over that did not have any hematologic disease. Results: The results were evaluated through descriptive statistical analysis, and comparison of mean values through the analysis of variance (Anova). In accordance with the results presented, there were not changes in the parameters by refrigerating the sample in the period of 8 hours, except for the platelet count, presenting oscillations when stored under refrigeration from 2°C to 8°C. Conclusion: At room temperature, the parameters mean corpuscular volume (MCV), mean corpuscular hemoglobin concentration (MCHC), and hematocrit presented significant statistical differences.Sociedade Brasileira de Patologia Clínica2020-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442020000100419Jornal Brasileiro de Patologia e Medicina Laboratorial v.56 2020reponame:Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)instname:Sociedade Brasileira de Patologia (SBP)instacron:SBP10.5935/1676-2444.20200037info:eu-repo/semantics/openAccessRiba,Vânia Cristina J.Pessini,Patrick Gabriel S.Chagas,Camila S.Neves,Daniel S.Gascón,Thaís M.Fonseca,Fernando Luiz A.Silva,Emerson B.eng2020-05-26T00:00:00Zoai:scielo:S1676-24442020000100419Revistahttp://www.scielo.br/jbpmlhttps://old.scielo.br/oai/scielo-oai.php||jbpml@sbpc.org.br1678-47741676-2444opendoar:2020-05-26T00:00Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) - Sociedade Brasileira de Patologia (SBP)false |
dc.title.none.fl_str_mv |
Interference of blood storage containing K2EDTA and K3EDTA anticoagulants in the automated analysis of the hemogram |
title |
Interference of blood storage containing K2EDTA and K3EDTA anticoagulants in the automated analysis of the hemogram |
spellingShingle |
Interference of blood storage containing K2EDTA and K3EDTA anticoagulants in the automated analysis of the hemogram Riba,Vânia Cristina J. edetic acid blood cell count anticoagulants |
title_short |
Interference of blood storage containing K2EDTA and K3EDTA anticoagulants in the automated analysis of the hemogram |
title_full |
Interference of blood storage containing K2EDTA and K3EDTA anticoagulants in the automated analysis of the hemogram |
title_fullStr |
Interference of blood storage containing K2EDTA and K3EDTA anticoagulants in the automated analysis of the hemogram |
title_full_unstemmed |
Interference of blood storage containing K2EDTA and K3EDTA anticoagulants in the automated analysis of the hemogram |
title_sort |
Interference of blood storage containing K2EDTA and K3EDTA anticoagulants in the automated analysis of the hemogram |
author |
Riba,Vânia Cristina J. |
author_facet |
Riba,Vânia Cristina J. Pessini,Patrick Gabriel S. Chagas,Camila S. Neves,Daniel S. Gascón,Thaís M. Fonseca,Fernando Luiz A. Silva,Emerson B. |
author_role |
author |
author2 |
Pessini,Patrick Gabriel S. Chagas,Camila S. Neves,Daniel S. Gascón,Thaís M. Fonseca,Fernando Luiz A. Silva,Emerson B. |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Riba,Vânia Cristina J. Pessini,Patrick Gabriel S. Chagas,Camila S. Neves,Daniel S. Gascón,Thaís M. Fonseca,Fernando Luiz A. Silva,Emerson B. |
dc.subject.por.fl_str_mv |
edetic acid blood cell count anticoagulants |
topic |
edetic acid blood cell count anticoagulants |
description |
ABSTRACT Introduction: The present work evaluated the possible alterations in different hemogram parameters as: total erythrocyte count, hematocrit, leukocyte, and platelet count, against different times of sample storage at refrigerated and room temperature towards the effects of anticoagulants that can affect the variation of laboratory results. Objective: Compare variations in automated hemogram analysis, with blood collected in tubes containing dipotassium ethylenediaminetetraacetic acid (K2EDTA) and tripotassium ethylenediaminetetraacetic acid (K3EDTA). Material and methods: A comparative study was carried out on differential leukocyte count and absolute leukocyte count, hemoglobin determination and red blood cell count and platelet count. Therefore, it researches the anticoagulant that brings less interferences in hemogram analysis according to storage, at temperatures from 2°C to 8°C and 25°C (room temperature), and the time window between collection and analysis (4, 6, and 8 hours). These determinations were carried out after homogenization from five to eight inversions using the automated device Sysmex XN-1000TM. Eighteen biological samples of venous blood were collected, used as control, from patients aged 18 and over that did not have any hematologic disease. Results: The results were evaluated through descriptive statistical analysis, and comparison of mean values through the analysis of variance (Anova). In accordance with the results presented, there were not changes in the parameters by refrigerating the sample in the period of 8 hours, except for the platelet count, presenting oscillations when stored under refrigeration from 2°C to 8°C. Conclusion: At room temperature, the parameters mean corpuscular volume (MCV), mean corpuscular hemoglobin concentration (MCHC), and hematocrit presented significant statistical differences. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442020000100419 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442020000100419 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/1676-2444.20200037 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Patologia Clínica |
publisher.none.fl_str_mv |
Sociedade Brasileira de Patologia Clínica |
dc.source.none.fl_str_mv |
Jornal Brasileiro de Patologia e Medicina Laboratorial v.56 2020 reponame:Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) instname:Sociedade Brasileira de Patologia (SBP) instacron:SBP |
instname_str |
Sociedade Brasileira de Patologia (SBP) |
instacron_str |
SBP |
institution |
SBP |
reponame_str |
Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) |
collection |
Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) |
repository.name.fl_str_mv |
Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) - Sociedade Brasileira de Patologia (SBP) |
repository.mail.fl_str_mv |
||jbpml@sbpc.org.br |
_version_ |
1752122297626394624 |