Resumo: Introduction:The most common cause of diagnostic error is related to errors in laboratory tests as well as errors of results interpretation. In order to reduce them, the laboratory currently has modern equipment which provides accurate and reliable results. The development of automation has revolutionized the laboratory procedures in Brazil and worldwide.Objective:To determine the prevalence of microscopic changes present in blood slides concordant and discordant with results obtained using fully automated procedures.Materials and method:From January to July 2013, 1,000 hematological parameters slides were analyzed. Automated analysis was performed on last generation equipment, which methodology is based on electrical impedance, and is able to quantify all the figurative elements of the blood in a universe of 22 parameters. The microscopy was performed by two experts in microscopy simultaneously.Results:The data showed that only 42.70% were concordant, comparing with 57.30% discordant. The main findings among discordant were: Changes in red blood cells 43.70% (n = 250), white blood cells 38.46% (n = 220), and number of platelet 17.80% (n = 102).Discussion:The data show that some results are not consistent with clinical or physiological state of an individual, and cannot be explained because they have not been investigated, which may compromise the final diagnosis.Conclusion:It was observed that it is of fundamental importance that the microscopy qualitative analysis must be performed in parallel with automated analysis in order to obtain reliable results, causing a positive impact on the prevention, diagnosis, prognosis, and therapeutic follow-up.
id SBP-1_c74496cf12a9a38047d4e4ebeace48d1
oai_identifier_str oai:scielo:S1676-24442014000600398
network_acronym_str SBP-1
network_name_str Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
repository_id_str
spelling Prevalence of discordant microscopic changes with automated CBC analysismicroscopyautomationCBCIntroduction:The most common cause of diagnostic error is related to errors in laboratory tests as well as errors of results interpretation. In order to reduce them, the laboratory currently has modern equipment which provides accurate and reliable results. The development of automation has revolutionized the laboratory procedures in Brazil and worldwide.Objective:To determine the prevalence of microscopic changes present in blood slides concordant and discordant with results obtained using fully automated procedures.Materials and method:From January to July 2013, 1,000 hematological parameters slides were analyzed. Automated analysis was performed on last generation equipment, which methodology is based on electrical impedance, and is able to quantify all the figurative elements of the blood in a universe of 22 parameters. The microscopy was performed by two experts in microscopy simultaneously.Results:The data showed that only 42.70% were concordant, comparing with 57.30% discordant. The main findings among discordant were: Changes in red blood cells 43.70% (n = 250), white blood cells 38.46% (n = 220), and number of platelet 17.80% (n = 102).Discussion:The data show that some results are not consistent with clinical or physiological state of an individual, and cannot be explained because they have not been investigated, which may compromise the final diagnosis.Conclusion:It was observed that it is of fundamental importance that the microscopy qualitative analysis must be performed in parallel with automated analysis in order to obtain reliable results, causing a positive impact on the prevention, diagnosis, prognosis, and therapeutic follow-up.Sociedade Brasileira de Patologia Clínica2014-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442014000600398Jornal Brasileiro de Patologia e Medicina Laboratorial v.50 n.6 2014reponame:Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)instname:Sociedade Brasileira de Patologia (SBP)instacron:SBP10.5935/1676-2444.20140047info:eu-repo/semantics/openAccessSantos,Fabiano de JesusFigueira,Dayse de OliveiraSouza,Joyce Eliza de Oliveiraeng2015-10-27T00:00:00Zoai:scielo:S1676-24442014000600398Revistahttp://www.scielo.br/jbpmlhttps://old.scielo.br/oai/scielo-oai.php||jbpml@sbpc.org.br1678-47741676-2444opendoar:2015-10-27T00:00Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) - Sociedade Brasileira de Patologia (SBP)false
dc.title.none.fl_str_mv Prevalence of discordant microscopic changes with automated CBC analysis
title Prevalence of discordant microscopic changes with automated CBC analysis
spellingShingle Prevalence of discordant microscopic changes with automated CBC analysis
Santos,Fabiano de Jesus
microscopy
automation
CBC
title_short Prevalence of discordant microscopic changes with automated CBC analysis
title_full Prevalence of discordant microscopic changes with automated CBC analysis
title_fullStr Prevalence of discordant microscopic changes with automated CBC analysis
title_full_unstemmed Prevalence of discordant microscopic changes with automated CBC analysis
title_sort Prevalence of discordant microscopic changes with automated CBC analysis
author Santos,Fabiano de Jesus
author_facet Santos,Fabiano de Jesus
Figueira,Dayse de Oliveira
Souza,Joyce Eliza de Oliveira
author_role author
author2 Figueira,Dayse de Oliveira
Souza,Joyce Eliza de Oliveira
author2_role author
author
dc.contributor.author.fl_str_mv Santos,Fabiano de Jesus
Figueira,Dayse de Oliveira
Souza,Joyce Eliza de Oliveira
dc.subject.por.fl_str_mv microscopy
automation
CBC
topic microscopy
automation
CBC
description Introduction:The most common cause of diagnostic error is related to errors in laboratory tests as well as errors of results interpretation. In order to reduce them, the laboratory currently has modern equipment which provides accurate and reliable results. The development of automation has revolutionized the laboratory procedures in Brazil and worldwide.Objective:To determine the prevalence of microscopic changes present in blood slides concordant and discordant with results obtained using fully automated procedures.Materials and method:From January to July 2013, 1,000 hematological parameters slides were analyzed. Automated analysis was performed on last generation equipment, which methodology is based on electrical impedance, and is able to quantify all the figurative elements of the blood in a universe of 22 parameters. The microscopy was performed by two experts in microscopy simultaneously.Results:The data showed that only 42.70% were concordant, comparing with 57.30% discordant. The main findings among discordant were: Changes in red blood cells 43.70% (n = 250), white blood cells 38.46% (n = 220), and number of platelet 17.80% (n = 102).Discussion:The data show that some results are not consistent with clinical or physiological state of an individual, and cannot be explained because they have not been investigated, which may compromise the final diagnosis.Conclusion:It was observed that it is of fundamental importance that the microscopy qualitative analysis must be performed in parallel with automated analysis in order to obtain reliable results, causing a positive impact on the prevention, diagnosis, prognosis, and therapeutic follow-up.
publishDate 2014
dc.date.none.fl_str_mv 2014-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442014000600398
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442014000600398
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/1676-2444.20140047
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv
Sociedade Brasileira de Patologia Clínica
publisher.none.fl_str_mv
Sociedade Brasileira de Patologia Clínica
dc.source.none.fl_str_mv Jornal Brasileiro de Patologia e Medicina Laboratorial v.50 n.6 2014
reponame:Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
instname:Sociedade Brasileira de Patologia (SBP)
instacron:SBP
instname_str Sociedade Brasileira de Patologia (SBP)
instacron_str SBP
institution SBP
reponame_str Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
collection Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
repository.name.fl_str_mv Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) - Sociedade Brasileira de Patologia (SBP)
repository.mail.fl_str_mv ||jbpml@sbpc.org.br
_version_ 1752122296233885696