Multichannel intraluminal impedance-pH and psychometric properties in gastroesophageal reflux: systematic review
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Jornal de Pediatria (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0021-75572020000600673 |
Resumo: | Abstract Objective: Systematically assess studies that have analyzed the psychometric properties of multichannel intraluminal impedance-pH for the diagnosis of gastroesophageal reflux. Systematically verify studies that have analyzed the psychometric properties of multichannel intraluminal impedance-pH regarding the diagnosis of gastroesophageal reflux disease in pediatric patients. Methods: Systematic review considering specific descriptors (children and adolescents, gastroesophageal reflux disease and multichannel intraluminal impedance-pH) and their synonyms. The systematic search was carried out in the MEDLINE/Ovid, Scopus, and Embase databases, considering the period from October 2017 to December 2018. This review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), which was used for study selection. The psychometric properties described in the studies were: sensitivity, specificity, accuracy, and reproducibility. Results: Sensitivity was discussed in most studies, with a result of more than 70% in four of them. Specificity was assessed only in conjunction with sensitivity, with values from 23% to 25% in two studies, and it reached 80% in a single study. Accuracy was assessed higher than 76% in one of the selected articles. The methodological quality of the studies demonstrated low risk of bias, and there was no significant concern related to applicability of the studies. Conclusions: According to the selected studies, multichannel intraluminal impedance-pH was considered a safe and effective tool, presenting higher sensitivity values than pHmetry regarding the diagnosis of gastroesophageal reflux disease. |
id |
SBPE-1_1430bb3ea35d5f36533c789f2a70bb62 |
---|---|
oai_identifier_str |
oai:scielo:S0021-75572020000600673 |
network_acronym_str |
SBPE-1 |
network_name_str |
Jornal de Pediatria (Online) |
repository_id_str |
|
spelling |
Multichannel intraluminal impedance-pH and psychometric properties in gastroesophageal reflux: systematic reviewGastroesophageal refluxPsychometric propertiesImpedance pHmetry, pediatricsAbstract Objective: Systematically assess studies that have analyzed the psychometric properties of multichannel intraluminal impedance-pH for the diagnosis of gastroesophageal reflux. Systematically verify studies that have analyzed the psychometric properties of multichannel intraluminal impedance-pH regarding the diagnosis of gastroesophageal reflux disease in pediatric patients. Methods: Systematic review considering specific descriptors (children and adolescents, gastroesophageal reflux disease and multichannel intraluminal impedance-pH) and their synonyms. The systematic search was carried out in the MEDLINE/Ovid, Scopus, and Embase databases, considering the period from October 2017 to December 2018. This review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), which was used for study selection. The psychometric properties described in the studies were: sensitivity, specificity, accuracy, and reproducibility. Results: Sensitivity was discussed in most studies, with a result of more than 70% in four of them. Specificity was assessed only in conjunction with sensitivity, with values from 23% to 25% in two studies, and it reached 80% in a single study. Accuracy was assessed higher than 76% in one of the selected articles. The methodological quality of the studies demonstrated low risk of bias, and there was no significant concern related to applicability of the studies. Conclusions: According to the selected studies, multichannel intraluminal impedance-pH was considered a safe and effective tool, presenting higher sensitivity values than pHmetry regarding the diagnosis of gastroesophageal reflux disease.Sociedade Brasileira de Pediatria2020-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0021-75572020000600673Jornal de Pediatria v.96 n.6 2020reponame:Jornal de Pediatria (Online)instname:Sociedade Brasileira de Pediatria (SBP)instacron:SBPE10.1016/j.jped.2020.01.005info:eu-repo/semantics/openAccessGonçalves,Emília SilvaAssumpção,Maíra Seabra deServidoni,Maria Fátima Correa PimentaLomazi,Elizete AparecidaRibeiro,José Dirceueng2020-12-10T00:00:00Zoai:scielo:S0021-75572020000600673Revistahttp://www.jped.com.br/https://old.scielo.br/oai/scielo-oai.php||jped@jped.com.br1678-47820021-7557opendoar:2020-12-10T00:00Jornal de Pediatria (Online) - Sociedade Brasileira de Pediatria (SBP)false |
dc.title.none.fl_str_mv |
Multichannel intraluminal impedance-pH and psychometric properties in gastroesophageal reflux: systematic review |
title |
Multichannel intraluminal impedance-pH and psychometric properties in gastroesophageal reflux: systematic review |
spellingShingle |
Multichannel intraluminal impedance-pH and psychometric properties in gastroesophageal reflux: systematic review Gonçalves,Emília Silva Gastroesophageal reflux Psychometric properties Impedance pHmetry, pediatrics |
title_short |
Multichannel intraluminal impedance-pH and psychometric properties in gastroesophageal reflux: systematic review |
title_full |
Multichannel intraluminal impedance-pH and psychometric properties in gastroesophageal reflux: systematic review |
title_fullStr |
Multichannel intraluminal impedance-pH and psychometric properties in gastroesophageal reflux: systematic review |
title_full_unstemmed |
Multichannel intraluminal impedance-pH and psychometric properties in gastroesophageal reflux: systematic review |
title_sort |
Multichannel intraluminal impedance-pH and psychometric properties in gastroesophageal reflux: systematic review |
author |
Gonçalves,Emília Silva |
author_facet |
Gonçalves,Emília Silva Assumpção,Maíra Seabra de Servidoni,Maria Fátima Correa Pimenta Lomazi,Elizete Aparecida Ribeiro,José Dirceu |
author_role |
author |
author2 |
Assumpção,Maíra Seabra de Servidoni,Maria Fátima Correa Pimenta Lomazi,Elizete Aparecida Ribeiro,José Dirceu |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Gonçalves,Emília Silva Assumpção,Maíra Seabra de Servidoni,Maria Fátima Correa Pimenta Lomazi,Elizete Aparecida Ribeiro,José Dirceu |
dc.subject.por.fl_str_mv |
Gastroesophageal reflux Psychometric properties Impedance pHmetry, pediatrics |
topic |
Gastroesophageal reflux Psychometric properties Impedance pHmetry, pediatrics |
description |
Abstract Objective: Systematically assess studies that have analyzed the psychometric properties of multichannel intraluminal impedance-pH for the diagnosis of gastroesophageal reflux. Systematically verify studies that have analyzed the psychometric properties of multichannel intraluminal impedance-pH regarding the diagnosis of gastroesophageal reflux disease in pediatric patients. Methods: Systematic review considering specific descriptors (children and adolescents, gastroesophageal reflux disease and multichannel intraluminal impedance-pH) and their synonyms. The systematic search was carried out in the MEDLINE/Ovid, Scopus, and Embase databases, considering the period from October 2017 to December 2018. This review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), which was used for study selection. The psychometric properties described in the studies were: sensitivity, specificity, accuracy, and reproducibility. Results: Sensitivity was discussed in most studies, with a result of more than 70% in four of them. Specificity was assessed only in conjunction with sensitivity, with values from 23% to 25% in two studies, and it reached 80% in a single study. Accuracy was assessed higher than 76% in one of the selected articles. The methodological quality of the studies demonstrated low risk of bias, and there was no significant concern related to applicability of the studies. Conclusions: According to the selected studies, multichannel intraluminal impedance-pH was considered a safe and effective tool, presenting higher sensitivity values than pHmetry regarding the diagnosis of gastroesophageal reflux disease. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0021-75572020000600673 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0021-75572020000600673 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1016/j.jped.2020.01.005 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Pediatria |
publisher.none.fl_str_mv |
Sociedade Brasileira de Pediatria |
dc.source.none.fl_str_mv |
Jornal de Pediatria v.96 n.6 2020 reponame:Jornal de Pediatria (Online) instname:Sociedade Brasileira de Pediatria (SBP) instacron:SBPE |
instname_str |
Sociedade Brasileira de Pediatria (SBP) |
instacron_str |
SBPE |
institution |
SBPE |
reponame_str |
Jornal de Pediatria (Online) |
collection |
Jornal de Pediatria (Online) |
repository.name.fl_str_mv |
Jornal de Pediatria (Online) - Sociedade Brasileira de Pediatria (SBP) |
repository.mail.fl_str_mv |
||jped@jped.com.br |
_version_ |
1752122322370691072 |