Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases

Detalhes bibliográficos
Autor(a) principal: Lugato,Isabel Cristina Prado Torres
Data de Publicação: 2009
Outros Autores: Pignatta,Lilian Maria Brisque, Arantes,Flávia de Moraes, Santos,Eduardo César Almada
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242009000400010
Resumo: This study aimed to compare in vitro the shear bond strength between metallic brackets (Abzil) with conventional mesh bases and metallic brackets with bases industrially sandblasted with aluminum oxide using three adhesive systems, in order to assess the influence of sandblasting on adhesiveness and to compare 3 different bonding systems. Two hundred and forty bovine incisors were used and randomly divided into 6 groups (40 teeth in each group), according to the bracket base and to the bonding system. The brackets were direct-bonded in bovine teeth with 3 adhesive systems: System A - conventional TransbondTM XT (3M - Unitek); System B - TransbondTM Plus Self Etching Primer + TransbondTM XT (3M - Unitek) and System C - Fuji ORTHO LC resin-reinforced glass ionomer cement in capsules (GC Corp.). Shear bond strength tests were performed 24 hours after bonding, in a DL-3000 universal testing machine (EMIC), using a load cell of 200 kgf and a speed of 1 mm/min. The results were submitted to statistical analysis and showed no significant difference between conventional and sandblasted bracket bases. However, comparison between the bonding systems presented significantly different results. System A (14.92 MPa) and system C (13.24 MPa) presented statistically greater shear bond strength when compared to system B (10.66 MPa). There was no statistically significant difference between system A and system C.
id SBPQO-1_531822457e5f3b08046e99c1f32c02dd
oai_identifier_str oai:scielo:S1806-83242009000400010
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket basesOrthodonticsShear strengthOrthodontic bracketsThis study aimed to compare in vitro the shear bond strength between metallic brackets (Abzil) with conventional mesh bases and metallic brackets with bases industrially sandblasted with aluminum oxide using three adhesive systems, in order to assess the influence of sandblasting on adhesiveness and to compare 3 different bonding systems. Two hundred and forty bovine incisors were used and randomly divided into 6 groups (40 teeth in each group), according to the bracket base and to the bonding system. The brackets were direct-bonded in bovine teeth with 3 adhesive systems: System A - conventional TransbondTM XT (3M - Unitek); System B - TransbondTM Plus Self Etching Primer + TransbondTM XT (3M - Unitek) and System C - Fuji ORTHO LC resin-reinforced glass ionomer cement in capsules (GC Corp.). Shear bond strength tests were performed 24 hours after bonding, in a DL-3000 universal testing machine (EMIC), using a load cell of 200 kgf and a speed of 1 mm/min. The results were submitted to statistical analysis and showed no significant difference between conventional and sandblasted bracket bases. However, comparison between the bonding systems presented significantly different results. System A (14.92 MPa) and system C (13.24 MPa) presented statistically greater shear bond strength when compared to system B (10.66 MPa). There was no statistically significant difference between system A and system C.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2009-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242009000400010Brazilian Oral Research v.23 n.4 2009reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242009000400010info:eu-repo/semantics/openAccessLugato,Isabel Cristina Prado TorresPignatta,Lilian Maria BrisqueArantes,Flávia de MoraesSantos,Eduardo César Almadaeng2009-12-15T00:00:00Zoai:scielo:S1806-83242009000400010Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2009-12-15T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases
title Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases
spellingShingle Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases
Lugato,Isabel Cristina Prado Torres
Orthodontics
Shear strength
Orthodontic brackets
title_short Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases
title_full Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases
title_fullStr Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases
title_full_unstemmed Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases
title_sort Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases
author Lugato,Isabel Cristina Prado Torres
author_facet Lugato,Isabel Cristina Prado Torres
Pignatta,Lilian Maria Brisque
Arantes,Flávia de Moraes
Santos,Eduardo César Almada
author_role author
author2 Pignatta,Lilian Maria Brisque
Arantes,Flávia de Moraes
Santos,Eduardo César Almada
author2_role author
author
author
dc.contributor.author.fl_str_mv Lugato,Isabel Cristina Prado Torres
Pignatta,Lilian Maria Brisque
Arantes,Flávia de Moraes
Santos,Eduardo César Almada
dc.subject.por.fl_str_mv Orthodontics
Shear strength
Orthodontic brackets
topic Orthodontics
Shear strength
Orthodontic brackets
description This study aimed to compare in vitro the shear bond strength between metallic brackets (Abzil) with conventional mesh bases and metallic brackets with bases industrially sandblasted with aluminum oxide using three adhesive systems, in order to assess the influence of sandblasting on adhesiveness and to compare 3 different bonding systems. Two hundred and forty bovine incisors were used and randomly divided into 6 groups (40 teeth in each group), according to the bracket base and to the bonding system. The brackets were direct-bonded in bovine teeth with 3 adhesive systems: System A - conventional TransbondTM XT (3M - Unitek); System B - TransbondTM Plus Self Etching Primer + TransbondTM XT (3M - Unitek) and System C - Fuji ORTHO LC resin-reinforced glass ionomer cement in capsules (GC Corp.). Shear bond strength tests were performed 24 hours after bonding, in a DL-3000 universal testing machine (EMIC), using a load cell of 200 kgf and a speed of 1 mm/min. The results were submitted to statistical analysis and showed no significant difference between conventional and sandblasted bracket bases. However, comparison between the bonding systems presented significantly different results. System A (14.92 MPa) and system C (13.24 MPa) presented statistically greater shear bond strength when compared to system B (10.66 MPa). There was no statistically significant difference between system A and system C.
publishDate 2009
dc.date.none.fl_str_mv 2009-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242009000400010
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242009000400010
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242009000400010
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.23 n.4 2009
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318321691000832