Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Oral Research |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242009000400010 |
Resumo: | This study aimed to compare in vitro the shear bond strength between metallic brackets (Abzil) with conventional mesh bases and metallic brackets with bases industrially sandblasted with aluminum oxide using three adhesive systems, in order to assess the influence of sandblasting on adhesiveness and to compare 3 different bonding systems. Two hundred and forty bovine incisors were used and randomly divided into 6 groups (40 teeth in each group), according to the bracket base and to the bonding system. The brackets were direct-bonded in bovine teeth with 3 adhesive systems: System A - conventional TransbondTM XT (3M - Unitek); System B - TransbondTM Plus Self Etching Primer + TransbondTM XT (3M - Unitek) and System C - Fuji ORTHO LC resin-reinforced glass ionomer cement in capsules (GC Corp.). Shear bond strength tests were performed 24 hours after bonding, in a DL-3000 universal testing machine (EMIC), using a load cell of 200 kgf and a speed of 1 mm/min. The results were submitted to statistical analysis and showed no significant difference between conventional and sandblasted bracket bases. However, comparison between the bonding systems presented significantly different results. System A (14.92 MPa) and system C (13.24 MPa) presented statistically greater shear bond strength when compared to system B (10.66 MPa). There was no statistically significant difference between system A and system C. |
id |
SBPQO-1_531822457e5f3b08046e99c1f32c02dd |
---|---|
oai_identifier_str |
oai:scielo:S1806-83242009000400010 |
network_acronym_str |
SBPQO-1 |
network_name_str |
Brazilian Oral Research |
repository_id_str |
|
spelling |
Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket basesOrthodonticsShear strengthOrthodontic bracketsThis study aimed to compare in vitro the shear bond strength between metallic brackets (Abzil) with conventional mesh bases and metallic brackets with bases industrially sandblasted with aluminum oxide using three adhesive systems, in order to assess the influence of sandblasting on adhesiveness and to compare 3 different bonding systems. Two hundred and forty bovine incisors were used and randomly divided into 6 groups (40 teeth in each group), according to the bracket base and to the bonding system. The brackets were direct-bonded in bovine teeth with 3 adhesive systems: System A - conventional TransbondTM XT (3M - Unitek); System B - TransbondTM Plus Self Etching Primer + TransbondTM XT (3M - Unitek) and System C - Fuji ORTHO LC resin-reinforced glass ionomer cement in capsules (GC Corp.). Shear bond strength tests were performed 24 hours after bonding, in a DL-3000 universal testing machine (EMIC), using a load cell of 200 kgf and a speed of 1 mm/min. The results were submitted to statistical analysis and showed no significant difference between conventional and sandblasted bracket bases. However, comparison between the bonding systems presented significantly different results. System A (14.92 MPa) and system C (13.24 MPa) presented statistically greater shear bond strength when compared to system B (10.66 MPa). There was no statistically significant difference between system A and system C.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2009-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242009000400010Brazilian Oral Research v.23 n.4 2009reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242009000400010info:eu-repo/semantics/openAccessLugato,Isabel Cristina Prado TorresPignatta,Lilian Maria BrisqueArantes,Flávia de MoraesSantos,Eduardo César Almadaeng2009-12-15T00:00:00Zoai:scielo:S1806-83242009000400010Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2009-12-15T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false |
dc.title.none.fl_str_mv |
Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases |
title |
Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases |
spellingShingle |
Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases Lugato,Isabel Cristina Prado Torres Orthodontics Shear strength Orthodontic brackets |
title_short |
Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases |
title_full |
Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases |
title_fullStr |
Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases |
title_full_unstemmed |
Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases |
title_sort |
Comparison of the shear bond strengths of conventional mesh bases and sandblasted orthodontic bracket bases |
author |
Lugato,Isabel Cristina Prado Torres |
author_facet |
Lugato,Isabel Cristina Prado Torres Pignatta,Lilian Maria Brisque Arantes,Flávia de Moraes Santos,Eduardo César Almada |
author_role |
author |
author2 |
Pignatta,Lilian Maria Brisque Arantes,Flávia de Moraes Santos,Eduardo César Almada |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Lugato,Isabel Cristina Prado Torres Pignatta,Lilian Maria Brisque Arantes,Flávia de Moraes Santos,Eduardo César Almada |
dc.subject.por.fl_str_mv |
Orthodontics Shear strength Orthodontic brackets |
topic |
Orthodontics Shear strength Orthodontic brackets |
description |
This study aimed to compare in vitro the shear bond strength between metallic brackets (Abzil) with conventional mesh bases and metallic brackets with bases industrially sandblasted with aluminum oxide using three adhesive systems, in order to assess the influence of sandblasting on adhesiveness and to compare 3 different bonding systems. Two hundred and forty bovine incisors were used and randomly divided into 6 groups (40 teeth in each group), according to the bracket base and to the bonding system. The brackets were direct-bonded in bovine teeth with 3 adhesive systems: System A - conventional TransbondTM XT (3M - Unitek); System B - TransbondTM Plus Self Etching Primer + TransbondTM XT (3M - Unitek) and System C - Fuji ORTHO LC resin-reinforced glass ionomer cement in capsules (GC Corp.). Shear bond strength tests were performed 24 hours after bonding, in a DL-3000 universal testing machine (EMIC), using a load cell of 200 kgf and a speed of 1 mm/min. The results were submitted to statistical analysis and showed no significant difference between conventional and sandblasted bracket bases. However, comparison between the bonding systems presented significantly different results. System A (14.92 MPa) and system C (13.24 MPa) presented statistically greater shear bond strength when compared to system B (10.66 MPa). There was no statistically significant difference between system A and system C. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242009000400010 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242009000400010 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1806-83242009000400010 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
dc.source.none.fl_str_mv |
Brazilian Oral Research v.23 n.4 2009 reponame:Brazilian Oral Research instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO) instacron:SBPQO |
instname_str |
Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
instacron_str |
SBPQO |
institution |
SBPQO |
reponame_str |
Brazilian Oral Research |
collection |
Brazilian Oral Research |
repository.name.fl_str_mv |
Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
repository.mail.fl_str_mv |
pob@edu.usp.br||bor@sbpqo.org.br |
_version_ |
1750318321691000832 |