Hausdorff Distance evaluation of orthodontic accessories' streaking artifacts in 3D model superimposition

Detalhes bibliográficos
Autor(a) principal: Rino Neto,José
Data de Publicação: 2012
Outros Autores: Silva,Fernando Penteado Lopes da, Chilvarquer,Israel, Paiva,João Batista de, Hernandez,Angélica Maria
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242012000500012
Resumo: The aim of this study was to determine whether image artifacts caused by orthodontic metal accessories interfere with the accuracy of 3D CBCT model superimposition. A human dry skull was subjected three times to a CBCT scan: at first without orthodontic brackets (T1), then with stainless steel brackets bonded without (T2) and with orthodontic arch wires (T3) inserted into the brackets' slots. The registration of image surfaces and the superimposition of 3D models were performed. Within-subject surface distances between T1-T2, T1-T3 and T2-T3 were computed and calculated for comparison among the three data sets. The minimum and maximum Hausdorff Distance units (HDu) computed between the corresponding data points of the T1 and T2 CBCT 3D surface images were 0.000000 and 0.049280 HDu, respectively, and the mean distance was 0.002497 HDu. The minimum and maximum Hausdorff Distances between T1 and T3 were 0.000000 and 0.047440 HDu, respectively, with a mean distance of 0.002585 HDu. In the comparison between T2 and T3, the minimum, maximum and mean Hausdorff Distances were 0.000000, 0.025616 and 0.000347 HDu, respectively. In the current study, the image artifacts caused by metal orthodontic accessories did not compromise the accuracy of the 3D model superimposition. Color-coded maps of overlaid structures complemented the computed Hausdorff Distances and demonstrated a precise fusion between the data sets.
id SBPQO-1_5bec6bd2cc677793585ed57fe6313b7d
oai_identifier_str oai:scielo:S1806-83242012000500012
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Hausdorff Distance evaluation of orthodontic accessories' streaking artifacts in 3D model superimpositionCone-Beam Computed TomographyOrthodonticsArtifactsThe aim of this study was to determine whether image artifacts caused by orthodontic metal accessories interfere with the accuracy of 3D CBCT model superimposition. A human dry skull was subjected three times to a CBCT scan: at first without orthodontic brackets (T1), then with stainless steel brackets bonded without (T2) and with orthodontic arch wires (T3) inserted into the brackets' slots. The registration of image surfaces and the superimposition of 3D models were performed. Within-subject surface distances between T1-T2, T1-T3 and T2-T3 were computed and calculated for comparison among the three data sets. The minimum and maximum Hausdorff Distance units (HDu) computed between the corresponding data points of the T1 and T2 CBCT 3D surface images were 0.000000 and 0.049280 HDu, respectively, and the mean distance was 0.002497 HDu. The minimum and maximum Hausdorff Distances between T1 and T3 were 0.000000 and 0.047440 HDu, respectively, with a mean distance of 0.002585 HDu. In the comparison between T2 and T3, the minimum, maximum and mean Hausdorff Distances were 0.000000, 0.025616 and 0.000347 HDu, respectively. In the current study, the image artifacts caused by metal orthodontic accessories did not compromise the accuracy of the 3D model superimposition. Color-coded maps of overlaid structures complemented the computed Hausdorff Distances and demonstrated a precise fusion between the data sets.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2012-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242012000500012Brazilian Oral Research v.26 n.5 2012reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242012000500012info:eu-repo/semantics/openAccessRino Neto,JoséSilva,Fernando Penteado Lopes daChilvarquer,IsraelPaiva,João Batista deHernandez,Angélica Mariaeng2012-09-21T00:00:00Zoai:scielo:S1806-83242012000500012Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2012-09-21T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Hausdorff Distance evaluation of orthodontic accessories' streaking artifacts in 3D model superimposition
title Hausdorff Distance evaluation of orthodontic accessories' streaking artifacts in 3D model superimposition
spellingShingle Hausdorff Distance evaluation of orthodontic accessories' streaking artifacts in 3D model superimposition
Rino Neto,José
Cone-Beam Computed Tomography
Orthodontics
Artifacts
title_short Hausdorff Distance evaluation of orthodontic accessories' streaking artifacts in 3D model superimposition
title_full Hausdorff Distance evaluation of orthodontic accessories' streaking artifacts in 3D model superimposition
title_fullStr Hausdorff Distance evaluation of orthodontic accessories' streaking artifacts in 3D model superimposition
title_full_unstemmed Hausdorff Distance evaluation of orthodontic accessories' streaking artifacts in 3D model superimposition
title_sort Hausdorff Distance evaluation of orthodontic accessories' streaking artifacts in 3D model superimposition
author Rino Neto,José
author_facet Rino Neto,José
Silva,Fernando Penteado Lopes da
Chilvarquer,Israel
Paiva,João Batista de
Hernandez,Angélica Maria
author_role author
author2 Silva,Fernando Penteado Lopes da
Chilvarquer,Israel
Paiva,João Batista de
Hernandez,Angélica Maria
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Rino Neto,José
Silva,Fernando Penteado Lopes da
Chilvarquer,Israel
Paiva,João Batista de
Hernandez,Angélica Maria
dc.subject.por.fl_str_mv Cone-Beam Computed Tomography
Orthodontics
Artifacts
topic Cone-Beam Computed Tomography
Orthodontics
Artifacts
description The aim of this study was to determine whether image artifacts caused by orthodontic metal accessories interfere with the accuracy of 3D CBCT model superimposition. A human dry skull was subjected three times to a CBCT scan: at first without orthodontic brackets (T1), then with stainless steel brackets bonded without (T2) and with orthodontic arch wires (T3) inserted into the brackets' slots. The registration of image surfaces and the superimposition of 3D models were performed. Within-subject surface distances between T1-T2, T1-T3 and T2-T3 were computed and calculated for comparison among the three data sets. The minimum and maximum Hausdorff Distance units (HDu) computed between the corresponding data points of the T1 and T2 CBCT 3D surface images were 0.000000 and 0.049280 HDu, respectively, and the mean distance was 0.002497 HDu. The minimum and maximum Hausdorff Distances between T1 and T3 were 0.000000 and 0.047440 HDu, respectively, with a mean distance of 0.002585 HDu. In the comparison between T2 and T3, the minimum, maximum and mean Hausdorff Distances were 0.000000, 0.025616 and 0.000347 HDu, respectively. In the current study, the image artifacts caused by metal orthodontic accessories did not compromise the accuracy of the 3D model superimposition. Color-coded maps of overlaid structures complemented the computed Hausdorff Distances and demonstrated a precise fusion between the data sets.
publishDate 2012
dc.date.none.fl_str_mv 2012-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242012000500012
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242012000500012
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242012000500012
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.26 n.5 2012
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318322926223360