Resumo: Abstract This study evaluated the stress behavior around short implants in edentulous atrophic mandibles. Six groups included implants with two diameters regular and wide (4 and 5 mm) and three lengths (5, 7 and 9 mm) as follows: Ci9 (9 x 4 mm), Ci7 (7 x 4 mm), Ci5 (5 x 4 mm), Wi9 (9 x 5 mm), Wi7 (7 x 5 mm) and Wi5 (5 x 5 mm). These groups were compared to the control group CG (11 x 4 mm). The analysis was performed with the photoelastic method (n = 6). Each model comprised 4 implants with the same length and diameter connected by a chromium-cobalt bar that simulates a fixed denture. A 0.15 kg force was applied at the end of the cantilever (15 mm), and the maximum shear stress was recorded around the distal and subsequent implants. The stress values were determined, and the quantitative data (Fringes®) were submitted to statistical analysis with one-way ANOVA and the Dunnett test (p < 0.05). It was observed that the reduction in implant length increased stress values with a significant difference (p < 0.05) between CG Ci7 and Ci5, while the increase in implant diameter reduced the stress values without any differences found between short and long implants. Implants with 5 and 7 mm with regular diameter increased stress levels while short implants with larger diameters experienced similar stress to that of longer implants.
id SBPQO-1_7d9d422db44dd23ef1c4ea1ba3e91c61
oai_identifier_str oai:scielo:S1806-83242017000100216
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Short implants to support mandibular complete dentures - photoelastic analysisDental ImplantsBone ResorptionDentureCompleteAbstract This study evaluated the stress behavior around short implants in edentulous atrophic mandibles. Six groups included implants with two diameters regular and wide (4 and 5 mm) and three lengths (5, 7 and 9 mm) as follows: Ci9 (9 x 4 mm), Ci7 (7 x 4 mm), Ci5 (5 x 4 mm), Wi9 (9 x 5 mm), Wi7 (7 x 5 mm) and Wi5 (5 x 5 mm). These groups were compared to the control group CG (11 x 4 mm). The analysis was performed with the photoelastic method (n = 6). Each model comprised 4 implants with the same length and diameter connected by a chromium-cobalt bar that simulates a fixed denture. A 0.15 kg force was applied at the end of the cantilever (15 mm), and the maximum shear stress was recorded around the distal and subsequent implants. The stress values were determined, and the quantitative data (Fringes®) were submitted to statistical analysis with one-way ANOVA and the Dunnett test (p < 0.05). It was observed that the reduction in implant length increased stress values with a significant difference (p < 0.05) between CG Ci7 and Ci5, while the increase in implant diameter reduced the stress values without any differences found between short and long implants. Implants with 5 and 7 mm with regular diameter increased stress levels while short implants with larger diameters experienced similar stress to that of longer implants.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2017-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242017000100216Brazilian Oral Research v.31 2017reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/1807-3107bor-2017.vol31.0018info:eu-repo/semantics/openAccessPIMENTEL,Marcele JardimSILVA,Wander José daDEL BEL CURY,Altair Antoninhaeng2017-02-21T00:00:00Zoai:scielo:S1806-83242017000100216Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2017-02-21T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Short implants to support mandibular complete dentures - photoelastic analysis
title Short implants to support mandibular complete dentures - photoelastic analysis
spellingShingle Short implants to support mandibular complete dentures - photoelastic analysis
PIMENTEL,Marcele Jardim
Dental Implants
Bone Resorption
Denture
Complete
title_short Short implants to support mandibular complete dentures - photoelastic analysis
title_full Short implants to support mandibular complete dentures - photoelastic analysis
title_fullStr Short implants to support mandibular complete dentures - photoelastic analysis
title_full_unstemmed Short implants to support mandibular complete dentures - photoelastic analysis
title_sort Short implants to support mandibular complete dentures - photoelastic analysis
author PIMENTEL,Marcele Jardim
author_facet PIMENTEL,Marcele Jardim
SILVA,Wander José da
DEL BEL CURY,Altair Antoninha
author_role author
author2 SILVA,Wander José da
DEL BEL CURY,Altair Antoninha
author2_role author
author
dc.contributor.author.fl_str_mv PIMENTEL,Marcele Jardim
SILVA,Wander José da
DEL BEL CURY,Altair Antoninha
dc.subject.por.fl_str_mv Dental Implants
Bone Resorption
Denture
Complete
topic Dental Implants
Bone Resorption
Denture
Complete
description Abstract This study evaluated the stress behavior around short implants in edentulous atrophic mandibles. Six groups included implants with two diameters regular and wide (4 and 5 mm) and three lengths (5, 7 and 9 mm) as follows: Ci9 (9 x 4 mm), Ci7 (7 x 4 mm), Ci5 (5 x 4 mm), Wi9 (9 x 5 mm), Wi7 (7 x 5 mm) and Wi5 (5 x 5 mm). These groups were compared to the control group CG (11 x 4 mm). The analysis was performed with the photoelastic method (n = 6). Each model comprised 4 implants with the same length and diameter connected by a chromium-cobalt bar that simulates a fixed denture. A 0.15 kg force was applied at the end of the cantilever (15 mm), and the maximum shear stress was recorded around the distal and subsequent implants. The stress values were determined, and the quantitative data (Fringes®) were submitted to statistical analysis with one-way ANOVA and the Dunnett test (p < 0.05). It was observed that the reduction in implant length increased stress values with a significant difference (p < 0.05) between CG Ci7 and Ci5, while the increase in implant diameter reduced the stress values without any differences found between short and long implants. Implants with 5 and 7 mm with regular diameter increased stress levels while short implants with larger diameters experienced similar stress to that of longer implants.
publishDate 2017
dc.date.none.fl_str_mv 2017-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242017000100216
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242017000100216
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1807-3107bor-2017.vol31.0018
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.31 2017
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318325236236288