Comparative study of methods for the quantification of biofilm on complete dentures

Detalhes bibliográficos
Autor(a) principal: Paranhos,Helena de Freitas Oliveira
Data de Publicação: 2004
Outros Autores: Silva,Cláudia Helena Lovato da
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300007
Resumo: This study compared the application and reliability of 4 methods for biofilm quantification (computerized, paper-weighing, point-counting, and planimetric) in complete dentures, verifying the correlation between them. The internal surfaces of 62 complete dentures were stained (5% erythrosine) and photographed. The slides were projected on paper, and the areas (total and biofilm-covered) were outlined with a pencil. These areas were measured with an equidistant point grid (point-counting method), a digital planimeter (planimetric method), and for the paper weighing method they were cut and weighed with a precision scale. For the computerized method, ImageTool software was used. In order to perform a validation test of the methods, all of them were applied to slide projections of geometric figures with known dimensions. The correlation tests showed high correlation values (r = 0.82 to 0.99) among the methods. The validation test (ANOVA) showed no statistically significant differences among the values obtained from the measurement of figures using all four quantitative methods and the real dimensions of these geometric figures. Quantitative methods were efficient and reliable for measuring quantity of biofilm in complete dentures, and may be useful in experimental studies on the efficacy of hygiene products. The computerized method was fast and easy to perform.
id SBPQO-1_98f4f24f700f853a601edad58a55fef6
oai_identifier_str oai:scielo:S1806-83242004000300007
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Comparative study of methods for the quantification of biofilm on complete denturesDenture, completeBiofilmsThis study compared the application and reliability of 4 methods for biofilm quantification (computerized, paper-weighing, point-counting, and planimetric) in complete dentures, verifying the correlation between them. The internal surfaces of 62 complete dentures were stained (5% erythrosine) and photographed. The slides were projected on paper, and the areas (total and biofilm-covered) were outlined with a pencil. These areas were measured with an equidistant point grid (point-counting method), a digital planimeter (planimetric method), and for the paper weighing method they were cut and weighed with a precision scale. For the computerized method, ImageTool software was used. In order to perform a validation test of the methods, all of them were applied to slide projections of geometric figures with known dimensions. The correlation tests showed high correlation values (r = 0.82 to 0.99) among the methods. The validation test (ANOVA) showed no statistically significant differences among the values obtained from the measurement of figures using all four quantitative methods and the real dimensions of these geometric figures. Quantitative methods were efficient and reliable for measuring quantity of biofilm in complete dentures, and may be useful in experimental studies on the efficacy of hygiene products. The computerized method was fast and easy to perform.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2004-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300007Brazilian Oral Research v.18 n.3 2004reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242004000300007info:eu-repo/semantics/openAccessParanhos,Helena de Freitas OliveiraSilva,Cláudia Helena Lovato daeng2004-09-29T00:00:00Zoai:scielo:S1806-83242004000300007Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2004-09-29T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Comparative study of methods for the quantification of biofilm on complete dentures
title Comparative study of methods for the quantification of biofilm on complete dentures
spellingShingle Comparative study of methods for the quantification of biofilm on complete dentures
Paranhos,Helena de Freitas Oliveira
Denture, complete
Biofilms
title_short Comparative study of methods for the quantification of biofilm on complete dentures
title_full Comparative study of methods for the quantification of biofilm on complete dentures
title_fullStr Comparative study of methods for the quantification of biofilm on complete dentures
title_full_unstemmed Comparative study of methods for the quantification of biofilm on complete dentures
title_sort Comparative study of methods for the quantification of biofilm on complete dentures
author Paranhos,Helena de Freitas Oliveira
author_facet Paranhos,Helena de Freitas Oliveira
Silva,Cláudia Helena Lovato da
author_role author
author2 Silva,Cláudia Helena Lovato da
author2_role author
dc.contributor.author.fl_str_mv Paranhos,Helena de Freitas Oliveira
Silva,Cláudia Helena Lovato da
dc.subject.por.fl_str_mv Denture, complete
Biofilms
topic Denture, complete
Biofilms
description This study compared the application and reliability of 4 methods for biofilm quantification (computerized, paper-weighing, point-counting, and planimetric) in complete dentures, verifying the correlation between them. The internal surfaces of 62 complete dentures were stained (5% erythrosine) and photographed. The slides were projected on paper, and the areas (total and biofilm-covered) were outlined with a pencil. These areas were measured with an equidistant point grid (point-counting method), a digital planimeter (planimetric method), and for the paper weighing method they were cut and weighed with a precision scale. For the computerized method, ImageTool software was used. In order to perform a validation test of the methods, all of them were applied to slide projections of geometric figures with known dimensions. The correlation tests showed high correlation values (r = 0.82 to 0.99) among the methods. The validation test (ANOVA) showed no statistically significant differences among the values obtained from the measurement of figures using all four quantitative methods and the real dimensions of these geometric figures. Quantitative methods were efficient and reliable for measuring quantity of biofilm in complete dentures, and may be useful in experimental studies on the efficacy of hygiene products. The computerized method was fast and easy to perform.
publishDate 2004
dc.date.none.fl_str_mv 2004-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300007
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300007
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242004000300007
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.18 n.3 2004
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318320313171968