Fractographic analysis, accuracy of fit and impact strength of acrylic resin

Detalhes bibliográficos
Autor(a) principal: Faot,Fernanda
Data de Publicação: 2008
Outros Autores: Garcia,Renata Cunha Matheus Rodrigues, Del Bel Cury,Altair Antoninha
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242008000400009
Resumo: This study evaluated accuracy of fit, impact strength, types and morphology of fractures of a microwave acrylic resin polymerized with a cycle alternative to that recommended by the manufacturer. Onda Cryl was polymerized according to the manufacturer's instructions (MC), 3 min at 360 W, 4-min pause, and 3 min at 810 W; and with an alternative cycle (AC) of 6 min at 630 W. Accuracy of fit was measured at 3 points at the right (A) and left (B) ridge crests and at the midline (C) on the posterior palatal seal for each denture base (n = 10/group). The measurements were taken immediately after finishing and after 30-day storage in water. The impact strength test (Charpy method) was performed with a 40 kJ/cm load (n = 20/group). Fractographic analysis was accomplished for all fragments and the fracture types were characterized by means of their morphology, crack propagation angles and microstructure. Accuracy of fit data were analyzed by ANOVA, impact strength and radius values were compared by the t test, and the fractographic analysis data, by the Wilcoxon Mann-Whitney test. The significance level was fixed at p < 0.05. No statistical differences were found between the two cycles of polymerization used. However, after the 30-day storage period in water, the denture bases showed better fit (P < .05). Most of the fractures were classified as brittle (MD: 70%, AC: 80%). Based on the results of this study, it could be concluded that both polymerization cycles are adequate to polymerize the denture resin studied.
id SBPQO-1_b23130cbbd13e2b030b221c4fa2e4d26
oai_identifier_str oai:scielo:S1806-83242008000400009
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Fractographic analysis, accuracy of fit and impact strength of acrylic resinDental materialsAcrylic resinsPhysical propertiesThis study evaluated accuracy of fit, impact strength, types and morphology of fractures of a microwave acrylic resin polymerized with a cycle alternative to that recommended by the manufacturer. Onda Cryl was polymerized according to the manufacturer's instructions (MC), 3 min at 360 W, 4-min pause, and 3 min at 810 W; and with an alternative cycle (AC) of 6 min at 630 W. Accuracy of fit was measured at 3 points at the right (A) and left (B) ridge crests and at the midline (C) on the posterior palatal seal for each denture base (n = 10/group). The measurements were taken immediately after finishing and after 30-day storage in water. The impact strength test (Charpy method) was performed with a 40 kJ/cm load (n = 20/group). Fractographic analysis was accomplished for all fragments and the fracture types were characterized by means of their morphology, crack propagation angles and microstructure. Accuracy of fit data were analyzed by ANOVA, impact strength and radius values were compared by the t test, and the fractographic analysis data, by the Wilcoxon Mann-Whitney test. The significance level was fixed at p < 0.05. No statistical differences were found between the two cycles of polymerization used. However, after the 30-day storage period in water, the denture bases showed better fit (P < .05). Most of the fractures were classified as brittle (MD: 70%, AC: 80%). Based on the results of this study, it could be concluded that both polymerization cycles are adequate to polymerize the denture resin studied.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2008-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242008000400009Brazilian Oral Research v.22 n.4 2008reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242008000400009info:eu-repo/semantics/openAccessFaot,FernandaGarcia,Renata Cunha Matheus RodriguesDel Bel Cury,Altair Antoninhaeng2009-10-20T00:00:00Zoai:scielo:S1806-83242008000400009Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2009-10-20T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Fractographic analysis, accuracy of fit and impact strength of acrylic resin
title Fractographic analysis, accuracy of fit and impact strength of acrylic resin
spellingShingle Fractographic analysis, accuracy of fit and impact strength of acrylic resin
Faot,Fernanda
Dental materials
Acrylic resins
Physical properties
title_short Fractographic analysis, accuracy of fit and impact strength of acrylic resin
title_full Fractographic analysis, accuracy of fit and impact strength of acrylic resin
title_fullStr Fractographic analysis, accuracy of fit and impact strength of acrylic resin
title_full_unstemmed Fractographic analysis, accuracy of fit and impact strength of acrylic resin
title_sort Fractographic analysis, accuracy of fit and impact strength of acrylic resin
author Faot,Fernanda
author_facet Faot,Fernanda
Garcia,Renata Cunha Matheus Rodrigues
Del Bel Cury,Altair Antoninha
author_role author
author2 Garcia,Renata Cunha Matheus Rodrigues
Del Bel Cury,Altair Antoninha
author2_role author
author
dc.contributor.author.fl_str_mv Faot,Fernanda
Garcia,Renata Cunha Matheus Rodrigues
Del Bel Cury,Altair Antoninha
dc.subject.por.fl_str_mv Dental materials
Acrylic resins
Physical properties
topic Dental materials
Acrylic resins
Physical properties
description This study evaluated accuracy of fit, impact strength, types and morphology of fractures of a microwave acrylic resin polymerized with a cycle alternative to that recommended by the manufacturer. Onda Cryl was polymerized according to the manufacturer's instructions (MC), 3 min at 360 W, 4-min pause, and 3 min at 810 W; and with an alternative cycle (AC) of 6 min at 630 W. Accuracy of fit was measured at 3 points at the right (A) and left (B) ridge crests and at the midline (C) on the posterior palatal seal for each denture base (n = 10/group). The measurements were taken immediately after finishing and after 30-day storage in water. The impact strength test (Charpy method) was performed with a 40 kJ/cm load (n = 20/group). Fractographic analysis was accomplished for all fragments and the fracture types were characterized by means of their morphology, crack propagation angles and microstructure. Accuracy of fit data were analyzed by ANOVA, impact strength and radius values were compared by the t test, and the fractographic analysis data, by the Wilcoxon Mann-Whitney test. The significance level was fixed at p < 0.05. No statistical differences were found between the two cycles of polymerization used. However, after the 30-day storage period in water, the denture bases showed better fit (P < .05). Most of the fractures were classified as brittle (MD: 70%, AC: 80%). Based on the results of this study, it could be concluded that both polymerization cycles are adequate to polymerize the denture resin studied.
publishDate 2008
dc.date.none.fl_str_mv 2008-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242008000400009
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242008000400009
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242008000400009
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.22 n.4 2008
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318321306173440