Dimensional stability of distances between posterior teeth in maxillary complete dentures

Detalhes bibliográficos
Autor(a) principal: Consani,Rafael Leonardo Xediek
Data de Publicação: 2006
Outros Autores: Mesquita,Marcelo Ferraz, Correr-Sobrinho,Lourenço, Tanji,Maurício
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242006000300011
Resumo: The aim of this study was to assess the displacement of posterior teeth in maxillary complete dentures stored in water at 37°C. Twenty acrylic resin-based maxillary complete dentures were constructed with the anterior teeth arranged in normal overlap and the posterior teeth in Angle class I. Metallic pins were placed on the labial cusp of the first premolars (PM), and on the mesiolabial cusp of the second molars (M). The final acrylic resin pressing was made in a metallic flask with aid of the RS tension system, and polymerized in a moist-hot cycle at 74°C for 9 hours. The dentures were deflasked after cooling in their own polymerizing water or after cooling in polymerizing water plus bench storage for 3 hours, and stored in water at 37°C for periods of 7, 30, and 90 days. Following deflasking and after each storage period tested, the PM-PM (premolar to premolar), M-M (molar to molar), LPM-LM (left premolar to left molar), and RPM-RM (right premolar to right molar) distances were measured with an STM Olympus microscope, with an accuracy of 0.0005 mm. Collected data were submitted to ANOVA and Tukey's test (5%). There was no statistically significant difference for the PM-PM, M-M, and LPM-LM distances after all storage periods when the flask cooling methods were considered. With exception of the RPM-RM distance after the 30-days water plus bench storage period, the other distances remained statistically stable.
id SBPQO-1_b8f6d3266dadf8e545d11abc6e5960f7
oai_identifier_str oai:scielo:S1806-83242006000300011
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Dimensional stability of distances between posterior teeth in maxillary complete denturesDenturecompleteWater storageTooth movementThe aim of this study was to assess the displacement of posterior teeth in maxillary complete dentures stored in water at 37°C. Twenty acrylic resin-based maxillary complete dentures were constructed with the anterior teeth arranged in normal overlap and the posterior teeth in Angle class I. Metallic pins were placed on the labial cusp of the first premolars (PM), and on the mesiolabial cusp of the second molars (M). The final acrylic resin pressing was made in a metallic flask with aid of the RS tension system, and polymerized in a moist-hot cycle at 74°C for 9 hours. The dentures were deflasked after cooling in their own polymerizing water or after cooling in polymerizing water plus bench storage for 3 hours, and stored in water at 37°C for periods of 7, 30, and 90 days. Following deflasking and after each storage period tested, the PM-PM (premolar to premolar), M-M (molar to molar), LPM-LM (left premolar to left molar), and RPM-RM (right premolar to right molar) distances were measured with an STM Olympus microscope, with an accuracy of 0.0005 mm. Collected data were submitted to ANOVA and Tukey's test (5%). There was no statistically significant difference for the PM-PM, M-M, and LPM-LM distances after all storage periods when the flask cooling methods were considered. With exception of the RPM-RM distance after the 30-days water plus bench storage period, the other distances remained statistically stable.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2006-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242006000300011Brazilian Oral Research v.20 n.3 2006reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242006000300011info:eu-repo/semantics/openAccessConsani,Rafael Leonardo XediekMesquita,Marcelo FerrazCorrer-Sobrinho,LourençoTanji,Maurícioeng2006-10-10T00:00:00Zoai:scielo:S1806-83242006000300011Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2006-10-10T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Dimensional stability of distances between posterior teeth in maxillary complete dentures
title Dimensional stability of distances between posterior teeth in maxillary complete dentures
spellingShingle Dimensional stability of distances between posterior teeth in maxillary complete dentures
Consani,Rafael Leonardo Xediek
Denture
complete
Water storage
Tooth movement
title_short Dimensional stability of distances between posterior teeth in maxillary complete dentures
title_full Dimensional stability of distances between posterior teeth in maxillary complete dentures
title_fullStr Dimensional stability of distances between posterior teeth in maxillary complete dentures
title_full_unstemmed Dimensional stability of distances between posterior teeth in maxillary complete dentures
title_sort Dimensional stability of distances between posterior teeth in maxillary complete dentures
author Consani,Rafael Leonardo Xediek
author_facet Consani,Rafael Leonardo Xediek
Mesquita,Marcelo Ferraz
Correr-Sobrinho,Lourenço
Tanji,Maurício
author_role author
author2 Mesquita,Marcelo Ferraz
Correr-Sobrinho,Lourenço
Tanji,Maurício
author2_role author
author
author
dc.contributor.author.fl_str_mv Consani,Rafael Leonardo Xediek
Mesquita,Marcelo Ferraz
Correr-Sobrinho,Lourenço
Tanji,Maurício
dc.subject.por.fl_str_mv Denture
complete
Water storage
Tooth movement
topic Denture
complete
Water storage
Tooth movement
description The aim of this study was to assess the displacement of posterior teeth in maxillary complete dentures stored in water at 37°C. Twenty acrylic resin-based maxillary complete dentures were constructed with the anterior teeth arranged in normal overlap and the posterior teeth in Angle class I. Metallic pins were placed on the labial cusp of the first premolars (PM), and on the mesiolabial cusp of the second molars (M). The final acrylic resin pressing was made in a metallic flask with aid of the RS tension system, and polymerized in a moist-hot cycle at 74°C for 9 hours. The dentures were deflasked after cooling in their own polymerizing water or after cooling in polymerizing water plus bench storage for 3 hours, and stored in water at 37°C for periods of 7, 30, and 90 days. Following deflasking and after each storage period tested, the PM-PM (premolar to premolar), M-M (molar to molar), LPM-LM (left premolar to left molar), and RPM-RM (right premolar to right molar) distances were measured with an STM Olympus microscope, with an accuracy of 0.0005 mm. Collected data were submitted to ANOVA and Tukey's test (5%). There was no statistically significant difference for the PM-PM, M-M, and LPM-LM distances after all storage periods when the flask cooling methods were considered. With exception of the RPM-RM distance after the 30-days water plus bench storage period, the other distances remained statistically stable.
publishDate 2006
dc.date.none.fl_str_mv 2006-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242006000300011
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242006000300011
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242006000300011
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.20 n.3 2006
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318320778739712